Biologic variation of immunoglobulin free light chains in serum

被引:0
|
作者
Braga, Federica [1 ,2 ]
Infusino, Ilenia [1 ,2 ]
Dolci, Alberto [2 ]
Panteghini, Mauro [1 ,2 ]
机构
[1] Univ Milan, Ctr Interdipartimentale Riferibilita Metrol Med L, Milan, Italy
[2] Azienda Osped Luigi Sacco, Lab Anal Chim Clin, Via GB Grassi 74, I-20157 Milan, Italy
关键词
D O I
暂无
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The measurement of serum kappa and lambda free light chains (FLC) and kappa/lambda FLC ratio calculation are recommended for screening, prognostic evaluation and monitoring of multiple myeloma and related plasma cell disorders. Given the lack of reliable data available in literature, in this study we assessed biologic variability components of FLCs and FLC ratio by an accurately designed protocol. We collected five blood specimens from each of 21 healthy volunteers (9 men and 12 women; age range, 23-54 years) on the same day, every two weeks for two months. Serum specimens were stored at -80 degrees C until analysis and analyzed in a single run in duplicate using a SPAPLuS immunoturbidimetric platform and Freelite reagents (The Binding Site). Data were analyzed by ANOVA. Serum lambda FLC concentrations were significantly (P < 0.01) higher in men. The inter-individual variance of lambda FLC was higher than that of kappa FLC. Within-and between-subject CVs were 8.1% and 14.1% for kappa FLC, 7.0% and 27.5% for lambda FLC, and 4.5% and 15.3% for FLC ratio. All parameters had marked individuality showing that the use of population-based reference intervals could be inadequate for test interpretation. The reference change value was between 20% and 30% depending from the assay imprecision. Desirable analytical goals for imprecision (CV), bias and total error were < 4.0%, +/- 4.1% and +/- 10.7% for FLC, < 3.5%, +/- 7.1% and +/- 12 .9% for lambda FLC, and < 2.3%, +/- 4.0% and +/- 7.7% for FLC ratio.
引用
收藏
页码:376 / 382
页数:7
相关论文
共 50 条
  • [1] Measurement of immunoglobulin free light chains in serum
    Mead, GP
    Drayson, MT
    Carr-Smith, HD
    Bradwell, AR
    CLINICAL CHEMISTRY, 2003, 49 (11) : 1957 - 1958
  • [2] Measurement of immunoglobulin free light chains in serum - Reply
    Tate, JR
    Mollee, P
    Gill, D
    CLINICAL CHEMISTRY, 2003, 49 (11) : 1958 - 1958
  • [3] Immunoglobulin free light chains in serum: a midstream biomarker
    Dolci, Alberto
    Panteghini, Mauro
    BIOCHIMICA CLINICA, 2013, 37 (05) : 344 - 346
  • [4] Biological variation of free light chains in serum
    Braga, Federica
    Infusino, Ilenia
    Dolci, Alberto
    Panteghini, Mauro
    CLINICA CHIMICA ACTA, 2013, 415 : 10 - 11
  • [5] Biological variation of free light chains in serum
    Zaninotto, Martina
    Altinier, Sara
    Varagnolo, Mariacristina
    Plebani, Mario
    CLINICA CHIMICA ACTA, 2013, 418 : 72 - 72
  • [6] Biological variation of free light chains in serum
    Hansen, Charlotte Toftmann
    Abildgaard, Niels
    CLINICA CHIMICA ACTA, 2014, 427 : 27 - 28
  • [7] Assays for immunoglobulin free light chains in serum on the Beckman Immage™.
    Harris, J
    Tang, LX
    Showell, P
    Carr-Smith, HD
    Drew, R
    Bradwell, AR
    CLINICAL CHEMISTRY, 2000, 46 (06) : A180 - A180
  • [8] Serum Immunoglobulin Free Light Chains in Patients with Monoclonal Gammapathies
    N. V. Lubimova
    T. A. Turko
    O. M. Votyakova
    N. E. Kushlinskii
    Bulletin of Experimental Biology and Medicine, 2012, 153 : 249 - 254
  • [9] Serum Immunoglobulin Free Light Chains in Patients with Monoclonal Gammapathies
    Lubimova, N. V.
    Turko, T. A.
    Votyakova, O. M.
    Kushlinskii, N. E.
    BULLETIN OF EXPERIMENTAL BIOLOGY AND MEDICINE, 2012, 153 (02) : 249 - 254
  • [10] The impact of exercise on the variation of serum free light chains
    Jacobs, Joannes F. M.
    Eijsvogels, Thijs M. H.
    van der Geest, Kornelis S. M.
    Koenen, Hans J. P. M.
    Hutchison, Colin A.
    Boots, Annemieke M. H.
    Hopman, Maria T. E.
    Joosten, Irma
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2014, 52 (11) : E239 - E242