Monitoring free light chains in serum using mass spectrometry

被引:38
|
作者
Barnidge, David R. [1 ]
Dispenzieri, Angela [1 ,2 ]
Merlini, Giampaolo [3 ]
Katzmann, Jerry A. [1 ]
Murray, David L. [1 ]
机构
[1] Mayo Clin, Dept Lab Med & Pathol, 200 1st St SW, Rochester, MN 55905 USA
[2] Mayo Clin, Dept Med, Rochester, MN 55905 USA
[3] IRCCS Policlin S Matteo, Biotechnol Res Labs, Pavia, Italy
关键词
free light chains; kappa; l; mass spectrometry; microflow LC-ESI-Q-TOF MS; monoclonal; INTACT MONOCLONAL-ANTIBODIES; ABSOLUTE QUANTIFICATION; POSTTRANSLATIONAL MODIFICATIONS; ELECTROSPRAY-IONIZATION; PROTEIN; IDENTIFICATION; MS;
D O I
10.1515/cclm-2015-0917
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Serum immunoglobulin free light chains (FLC) are secreted into circulation by plasma cells as a by-product of immunoglobulin production. In a healthy individual the population of FLC is polyclonal as no single cell is secreting more FLC than the total immunoglobulin secreting cell population. In a person with a plasma cell dyscrasia, such as multiple myeloma (MM) or light chain amyloidosis (AL), a clonal population of plasma cells secretes a monoclonal light chain at a concentration above the normal polyclonal background. Methods: We recently showed that monoclonal immunoglobulin rapid accurate mass measurement (miRAMM) can be used to identify and quantify a monoclonal light chain (LC) in serum and urine above the polyclonal background. This was accomplished by reducing immunoglobulin disulfide bonds releasing the LC to be analyzed by microLC-ESI-Q-TOF mass spectrometry. Here we demonstrate that the methodology can also be applied to the detection and quantification of FLC by analyzing a non-reduced sample. Results: Proof of concept experiments were performed using purified FLC spiked into normal serum to assess linearity and precision. In addition, a cohort of 27 patients with AL was analyzed and miRAMM was able to detect a monoclonal FLC in 23 of the 27 patients that had abnormal FLC values by immunonephelometry. Conclusions: The high resolution and high mass measurement accuracy provided by the mass spectrometry based methodology eliminates the need for kappa/lambda ratios as the method can quantitatively monitor the abundance of the kappa and lambda polyclonal background at the same time it measures the monoclonal FLC.
引用
收藏
页码:1073 / 1083
页数:11
相关论文
共 50 条
  • [41] Serum free light chains levels in patients with monoclonal gammopathy
    Dajak, M.
    Maksic, N.
    CLINICA CHIMICA ACTA, 2024, 558 : 1 - 2
  • [42] Assays for immunoglobulin free light chains in serum on the Beckman Immage™.
    Harris, J
    Tang, LX
    Showell, P
    Carr-Smith, HD
    Drew, R
    Bradwell, AR
    CLINICAL CHEMISTRY, 2000, 46 (06) : A180 - A180
  • [43] Serum free light chains as a biomarker in systemic lupus erythematosus
    Aggarwal, Rohit
    Mikolaitis, R.
    Alvi, S.
    Assi, L.
    Block, J.
    Jolly, M.
    Sequeira, W.
    ARTHRITIS AND RHEUMATISM, 2008, 58 (09): : S572 - S572
  • [44] Reduction of serum free light chains predict renal recovery
    Colin A. Hutchison
    Annals of Hematology, 2010, 89 : 627 - 628
  • [45] Serum Free Light Chains and the Risk of ESRD and Death in CKD
    Haynes, Richard
    Hutchison, Colin A.
    Emberson, Jonathan
    Dasgupta, Tanaji
    Wheeler, David C.
    Townend, John N.
    Landray, Martin J.
    Cockwell, Paul
    CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2011, 6 (12): : 2829 - 2837
  • [46] Detection of serum free light chains: the problem with antigen excess
    Bosmann, Markus
    Koessler, Juergen
    Stolz, Herbert
    Walter, Ulrich
    Knop, Stefan
    Steigerwald, Udo
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2010, 48 (10) : 1419 - 1422
  • [47] Serum Immunoglobulin Free Light Chains in Patients with Monoclonal Gammapathies
    N. V. Lubimova
    T. A. Turko
    O. M. Votyakova
    N. E. Kushlinskii
    Bulletin of Experimental Biology and Medicine, 2012, 153 : 249 - 254
  • [48] Determination of free light chains in serum: analytical and clinical aspects
    Albertini, Riccardo
    Merlini, Giannpaolo
    BIOCHIMICA CLINICA, 2010, 34 (01) : 26 - 29
  • [49] Serum free light chains reference intervals for the Lebanese population
    El Karaaoui, Abdulkarim
    Ghandour, Lina
    Daher, Rose T.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2024,
  • [50] Assessment of free light chains assays in serum on the Beckman IMMAGE™.
    Ong, S
    Sethi, S
    CLINICAL CHEMISTRY, 2003, 49 (06) : A106 - A106