Accurate measurement of interferometer group delay using field-compensated scanning white light interferometer

被引:5
|
作者
Wan, Xiaoke [1 ]
Wang, Ji [1 ]
Ge, Jian [1 ]
机构
[1] Univ Florida, Dept Astron, Bryant Space Sci Ctr 211, Gainesville, FL 32611 USA
基金
美国国家科学基金会;
关键词
MICHELSON INTERFEROMETER; DISPERSION;
D O I
10.1364/AO.49.005645
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Interferometers are key elements in radial velocity (RV) experiments in astronomy observations, and accurate calibration of the group delay of an interferometer is required for high precision measurements. A novel field-compensated white light scanning Michelson interferometer is introduced as an interferometer calibration tool. The optical path difference (OPD) scanning was achieved by translating a compensation prism, such that even if the light source were in low spatial coherence, the interference stays spatially phase coherent over a large interferometer scanning range. In the wavelength region of 500-560 nm, a multimode fiber-coupled LED was used as the light source, and high optical efficiency was essential in elevating the signal-to-noise ratio of the interferogram signal. The achromatic OPD scanning required a one-time calibration, and two methods using dual-laser wavelength references and an iodine absorption spectrum reference were employed and cross-verified. In an experiment measuring the group delay of a fixed Michelson interferometer, Fourier analysis was employed to process the interferogram data. The group delay was determined at an accuracy of 1 x 10(-5), and the phase angle precision was typically 2.5 x 10(-6) over the wide wavelength region. (C) 2010 Optical Society of America
引用
收藏
页码:5645 / 5653
页数:9
相关论文
共 50 条
  • [41] Gauge block measurement using a wavelength scanning interferometer
    Bitou, Y
    Seta, K
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 2000, 39 (10): : 6084 - 6088
  • [42] Fiber optic white light interferometer for areal surface measurement
    Zhang, Guofeng
    Yang, Shuming
    Fluegge, Jens
    Bosse, Harald
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2020, 31 (02)
  • [43] Self-calibrating lateral scanning white-light interferometer
    Munteanu, Florin
    INTERFEROMETRY XV: TECHNIQUES AND ANALYSIS, 2010, 7790
  • [44] Self-calibrating lateral scanning white-light interferometer
    Munteanu, Florin
    APPLIED OPTICS, 2010, 49 (12) : 2371 - 2375
  • [45] Quasidynamic calibration of stroboscopic scanning white light interferometer with a transfer standard
    Seppa, Jeremias
    Kassamakov, Ivan
    Heikkinen, Ville
    Nolvi, Anton
    Paulin, Tor
    Lassila, Antti
    Haeggstrom, Edward
    OPTICAL ENGINEERING, 2013, 52 (12)
  • [46] Static and (quasi)dynamic calibration of stroboscopic scanning white light interferometer
    Seppa, Jeremias
    Kassamakov, Ivan
    Nolvi, Anton
    Heikkinen, Ville
    Paulin, Tor
    Lassila, Antti
    Hao, Ling
    Haeggsrom, Edward
    OPTICAL MEASUREMENT SYSTEMS FOR INDUSTRIAL INSPECTION VIII, 2013, 8788
  • [47] Modified white-light Mach-Zehnder interferometer for direct group-delay measurements
    Liang, Yi
    Grover, Chandler P.
    Applied Optics, 1998, 37 (19): : 4105 - 4111
  • [48] Modified white-light Mach-Zehnder interferometer for direct group-delay measurements
    Liang, Y
    Grover, CP
    APPLIED OPTICS, 1998, 37 (19): : 4105 - 4111
  • [49] Exact surface measurement based on phase error insensitive method for white-light scanning interferometer
    Ji, Changsheng
    Luo, Songjie
    Sasaki, Osami
    Chen, Ziyang
    Pu, Jixiong
    SURFACE TOPOGRAPHY-METROLOGY AND PROPERTIES, 2024, 12 (02):
  • [50] Signal correction by detection of scanning position in a white-light interferometer for exact surface profile measurement
    Luo, Songjie
    Suzuki, Takamasa
    Sasaki, Osami
    Choi, Samuel
    Chen, Ziyang
    Pu, Jixiong