Accurate measurement of interferometer group delay using field-compensated scanning white light interferometer

被引:5
|
作者
Wan, Xiaoke [1 ]
Wang, Ji [1 ]
Ge, Jian [1 ]
机构
[1] Univ Florida, Dept Astron, Bryant Space Sci Ctr 211, Gainesville, FL 32611 USA
基金
美国国家科学基金会;
关键词
MICHELSON INTERFEROMETER; DISPERSION;
D O I
10.1364/AO.49.005645
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Interferometers are key elements in radial velocity (RV) experiments in astronomy observations, and accurate calibration of the group delay of an interferometer is required for high precision measurements. A novel field-compensated white light scanning Michelson interferometer is introduced as an interferometer calibration tool. The optical path difference (OPD) scanning was achieved by translating a compensation prism, such that even if the light source were in low spatial coherence, the interference stays spatially phase coherent over a large interferometer scanning range. In the wavelength region of 500-560 nm, a multimode fiber-coupled LED was used as the light source, and high optical efficiency was essential in elevating the signal-to-noise ratio of the interferogram signal. The achromatic OPD scanning required a one-time calibration, and two methods using dual-laser wavelength references and an iodine absorption spectrum reference were employed and cross-verified. In an experiment measuring the group delay of a fixed Michelson interferometer, Fourier analysis was employed to process the interferogram data. The group delay was determined at an accuracy of 1 x 10(-5), and the phase angle precision was typically 2.5 x 10(-6) over the wide wavelength region. (C) 2010 Optical Society of America
引用
收藏
页码:5645 / 5653
页数:9
相关论文
共 50 条
  • [21] Accurate Group-Delay Measurement for Radial-Velocity Instruments Using the Dispersed Fixed-Delay Interferometer Method
    Wang, Ji
    Ge, Jian
    Wan, Xiaoke
    Lee, Brian
    De Lee, Nathan
    PUBLICATIONS OF THE ASTRONOMICAL SOCIETY OF THE PACIFIC, 2012, 124 (916) : 598 - 605
  • [22] Scanning white-light interferometer for measurement of the thickness of a transparent oil film on water
    Sun, CS
    Yu, LC
    Sun, YX
    Yu, QX
    APPLIED OPTICS, 2005, 44 (25) : 5202 - 5205
  • [23] Application of white-light scanning interferometer on transparent thin-film measurement
    Li, Meng-Chi
    Wan, Der-Shen
    Lee, Cheng-Chung
    APPLIED OPTICS, 2012, 51 (36) : 8579 - 8586
  • [24] Accurate Force Measurement Using Optical Interferometer
    Fujii, Yusaku
    INTERNATIONAL CONFERENCE ON PHYSICS AND ITS APPLICATIONS (ICPAP 2011), 2012, 1454 : 15 - 18
  • [25] Nanodisplacement measurement using spectral shifts in a white-light interferometer
    Brundavanam, Maruthi M.
    Viswanathan, Nirmal K.
    Rao, D. Narayana
    APPLIED OPTICS, 2008, 47 (34) : 6334 - 6339
  • [26] Measurement accuracy of the white light interferometer with reference light beam
    Skiba-Szymanska, Joanna
    Patela, Sergiusz
    Proceedings of the 2005 International Students and Young Scientists Workshop Photonics and Microsystems, 2005, : 73 - 77
  • [27] A white light interferometer for measurement of external cylindrical surfaces
    Albertazzi, A
    Dal Pont, A
    FRINGE 2005, 2006, : 632 - +
  • [28] Applications of a White Light Interferometer for Wear Measurement of Cylinders
    Albertazzi, A., Jr.
    Viotti, M. R.
    Miggiorin, R. M.
    Dal Pont, A.
    INTERFEROMETRY XIV: APPLICATIONS, 2008, 7064
  • [29] Demonstration of a white light interferometer using fast light
    Pati, G. S.
    Messal, M.
    Shahriar, M. S.
    ADVANCED OPTICAL AND QUANTUM MEMORIES AND COMPUTING IV, 2007, 6482
  • [30] Performance evaluation of a vibration desensitized scanning white light interferometer
    Troutman, J.
    Evans, C. J.
    Ganguly, V.
    Schmitz, T. L.
    SURFACE TOPOGRAPHY-METROLOGY AND PROPERTIES, 2014, 2 (01)