Validation of Ankle Strength Measurements by Means of a Hand-Held Dynamometer in Adult Healthy Subjects

被引:8
|
作者
Ancillao, Andrea [1 ]
Palermo, Eduardo [1 ]
Rossi, Stefano [2 ]
机构
[1] Sapienza Univ Rome, Dept Mech & Aerosp Engn, Via Eudossiana 18, I-00184 Rome, Italy
[2] Univ Tuscia, Dept Econ & Management Ind Engn DEIM, Via Paradiso 47, I-01100 Viterbo, Italy
关键词
MUSCLE STRENGTH; GAIT PATTERN; RELIABILITY; KNEE; VALIDITY; QUALITY; CHILDREN; POSTURE; TORQUE; MOTION;
D O I
10.1155/2017/5426031
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Uniaxial Hand-Held Dynamometer (HHD) is a low-cost device widely adopted in clinical practice to measure muscle force. HHD measurements depend on operator's ability and joint movements. The aim of the work is to validate the use of a commercial HHD in both dorsiflexion and plantarflexion ankle strength measurements quantifying the effects of HHD misplacements and unwanted foot's movements on the measurements. We used an optoelectronic system and a multicomponent load cell to quantify the sources of error in the manual assessment of the ankle strength due to both the operator's ability to hold still the HHD and the transversal components of the exerted force that are usually neglected in clinical routine. Results showed that foot's movements and angular misplacements of HHD on sagittal and horizontal planes were relevant sources of inaccuracy on the strength assessment. Moreover, ankle dorsiflexion and plantarflexion force measurements presented an inaccuracy less than 2% and higher than 10%, respectively. In conclusion, the manual use of a uniaxial HHD is not recommended for the assessment of ankle plantarflexion strength; on the contrary, it can be allowed asking the operator to pay strong attention to the HHD positioning in ankle dorsiflexion strength measurements.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Strength of the intrinsic muscles of the hand measured with a hand-held dynamometer: Reliability in patients with ulnar and median nerve paralysis
    Schreuders, TAR
    Roebroeck, M
    Van der Kar, TJM
    Soeters, JNM
    Hovius, SER
    Stam, HJ
    JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 2000, 25B (06): : 560 - 565
  • [42] INTRATESTER RELIABILITY OF STRENGTH TESTING IN DYSTROPHIC AND NORMAL-CHILDREN USING A HAND-HELD DYNAMOMETER
    STUBERG, WA
    METCALF, WK
    PHYSICAL THERAPY, 1986, 66 (05): : 800 - 800
  • [43] Reliability and validity of eccentric strength measurement of the shoulder abductor muscles using a hand-held dynamometer
    Karabay, Damla
    Yesilyaprak, Sevgi Sevi
    Picak, Gonca Sahiner
    PHYSICAL THERAPY IN SPORT, 2020, 43 : 52 - 57
  • [44] Reliability and validity of the hand-held dynamometer "NOD": a new instrument for assessment of isometric grip strength
    Sartorio, Francesco
    Lippi, Lorenzo
    Vercelli, Stefano
    Gallo, Federica
    Zanin, Davide
    Bergesio, Sara
    de Sire, Alessandro
    Invernizzi, Marco
    BMC MUSCULOSKELETAL DISORDERS, 2025, 26 (01)
  • [45] Reliability of isometric knee extension muscle strength measurements made by a hand-held dynamometer and a belt: a comparison of two types of device
    Katoh, Munenori
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2015, 27 (03) : 851 - 854
  • [46] Reliability of Hand-Held Dynamometer Measurement for Thumb Palmar Abduction Strength in Carpal Tunnel Syndrome
    Doi, Kazuteru
    Yasui, Noritada
    Isomura, Yuya
    Tagawa, Masafumi
    Hattori, Yasunori
    Sakamoto, Sotetsu
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2025,
  • [47] INTERDEVICE RELIABILITY AND VALIDITY ASSESSMENT OF THE NICHOLAS HAND-HELD DYNAMOMETER
    TRUDELLEJACKSON, E
    JACKSON, AW
    FRANKOWSKI, CM
    LONG, KM
    MESKE, NB
    JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 1994, 20 (06): : 302 - 306
  • [48] INTRASESSION AND INTERSESSION RELIABILITY OF HAND-HELD DYNAMOMETER MEASUREMENTS TAKEN ON BRAIN-DAMAGED PATIENTS
    RIDDLE, DL
    FINUCANE, SD
    ROTHSTEIN, JM
    WALKER, ML
    PHYSICAL THERAPY, 1989, 69 (03): : 182 - 189
  • [49] INTERTESTER RELIABILITY OF THE HAND-HELD DYNAMOMETER FOR WRIST FLEXION AND EXTENSION
    RHEAULT, W
    BEAL, JL
    KUBIK, KR
    NOWAK, TA
    SHEPLEY, JA
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1989, 70 (13): : 907 - 910
  • [50] Reliability assessment of isometric knee extension measurements with a computer-assisted hand-held dynamometer
    Roebroeck, ME
    Harlaar, J
    Lankhorst, GJ
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1998, 79 (04): : 442 - 448