Validation of Ankle Strength Measurements by Means of a Hand-Held Dynamometer in Adult Healthy Subjects

被引:8
|
作者
Ancillao, Andrea [1 ]
Palermo, Eduardo [1 ]
Rossi, Stefano [2 ]
机构
[1] Sapienza Univ Rome, Dept Mech & Aerosp Engn, Via Eudossiana 18, I-00184 Rome, Italy
[2] Univ Tuscia, Dept Econ & Management Ind Engn DEIM, Via Paradiso 47, I-01100 Viterbo, Italy
关键词
MUSCLE STRENGTH; GAIT PATTERN; RELIABILITY; KNEE; VALIDITY; QUALITY; CHILDREN; POSTURE; TORQUE; MOTION;
D O I
10.1155/2017/5426031
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Uniaxial Hand-Held Dynamometer (HHD) is a low-cost device widely adopted in clinical practice to measure muscle force. HHD measurements depend on operator's ability and joint movements. The aim of the work is to validate the use of a commercial HHD in both dorsiflexion and plantarflexion ankle strength measurements quantifying the effects of HHD misplacements and unwanted foot's movements on the measurements. We used an optoelectronic system and a multicomponent load cell to quantify the sources of error in the manual assessment of the ankle strength due to both the operator's ability to hold still the HHD and the transversal components of the exerted force that are usually neglected in clinical routine. Results showed that foot's movements and angular misplacements of HHD on sagittal and horizontal planes were relevant sources of inaccuracy on the strength assessment. Moreover, ankle dorsiflexion and plantarflexion force measurements presented an inaccuracy less than 2% and higher than 10%, respectively. In conclusion, the manual use of a uniaxial HHD is not recommended for the assessment of ankle plantarflexion strength; on the contrary, it can be allowed asking the operator to pay strong attention to the HHD positioning in ankle dorsiflexion strength measurements.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] The Concurrent Validity of a Hand-held versus a Stationary Dynamometer in Testing Isometric Shoulder Strength
    Roy, Jean-Sebastien
    MacDermid, Joy C.
    Orton, Brock
    Tran, Thomas
    Faber, Kenneth J.
    Drosdowech, Darren
    Athwal, George S.
    JOURNAL OF HAND THERAPY, 2009, 22 (04) : 320 - 326
  • [32] Validity And Reliability Of Hand-held Dynamometer In Assessing Isometric Leg Strength In Older Adults
    Lee, Chong-Do
    Lee, Samuel
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2022, 54 (09) : 477 - 477
  • [33] VALIDITY AND RELIABILITY OF A HAND-HELD DYNAMOMETER WITH 2 POPULATIONS
    SURBURG, PR
    SUOMI, R
    POPPY, WK
    JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 1992, 16 (05): : 229 - 234
  • [34] HAND-HELD DYNAMOMETER FOR EVALUATING VOLUNTARY MUSCLE FUNCTION
    EDWARDS, RHT
    MCDONNELL, M
    LANCET, 1974, 2 (7883): : 757 - 758
  • [35] Knee and hip strength measurements obtained by a hand-held dynamometer stabilized by a belt and an examiner demonstrate parallel reliability but not agreement
    Florencio, Lidiane L.
    Martins, Jaqueline
    da Silva, Marcelo R. B.
    da Silva, Janaina R.
    Bellizzi, Gustavo L.
    Bevilaqua-Grossi, Debora
    PHYSICAL THERAPY IN SPORT, 2019, 38 : 115 - 122
  • [36] Comparison of Reliability of Isometric Leg Muscle Strength Measurements Made Using a Hand-Held Dynamometer with and without a Restraining Belt
    Katoh, Munenori
    Yamasaki, Hiroshi
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2009, 21 (01) : 37 - 42
  • [37] Hand-held dynamometer measurements obtained in a home environment are reliable but not correlated strongly with function
    Bohannon, RW
    INTERNATIONAL JOURNAL OF REHABILITATION RESEARCH, 1996, 19 (04) : 345 - 347
  • [38] Reliability of Isometric Knee Extension Muscle Strength Measurement Using a Hand-held Dynamometer with a Belt: A Study of Test-retest Reliability in Healthy Elderly Subjects
    Katoh, Munenori
    Isozaki, Koji
    Sakanoue, Noboru
    Miyahara, Takuya
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2010, 22 (04) : 359 - 363
  • [39] CONTROLLING SNOW SURFACE STRENGTH MEASUREMENTS WITH A HAND-HELD CALCULATOR
    MARTINELLI, M
    OZMENT, A
    COLD REGIONS SCIENCE AND TECHNOLOGY, 1984, 9 (03) : 277 - 281
  • [40] Effectiveness of the Copenhagen adduction modified position stage 1: EMG measurements and hand-held dynamometer analysis in young and healthy men
    Hinnekens, Simon
    Fickers, Elene
    Vervloet, Gregory
    JOURNAL OF BODYWORK AND MOVEMENT THERAPIES, 2024, 39 : 251 - 257