Validation of Ankle Strength Measurements by Means of a Hand-Held Dynamometer in Adult Healthy Subjects

被引:8
|
作者
Ancillao, Andrea [1 ]
Palermo, Eduardo [1 ]
Rossi, Stefano [2 ]
机构
[1] Sapienza Univ Rome, Dept Mech & Aerosp Engn, Via Eudossiana 18, I-00184 Rome, Italy
[2] Univ Tuscia, Dept Econ & Management Ind Engn DEIM, Via Paradiso 47, I-01100 Viterbo, Italy
关键词
MUSCLE STRENGTH; GAIT PATTERN; RELIABILITY; KNEE; VALIDITY; QUALITY; CHILDREN; POSTURE; TORQUE; MOTION;
D O I
10.1155/2017/5426031
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Uniaxial Hand-Held Dynamometer (HHD) is a low-cost device widely adopted in clinical practice to measure muscle force. HHD measurements depend on operator's ability and joint movements. The aim of the work is to validate the use of a commercial HHD in both dorsiflexion and plantarflexion ankle strength measurements quantifying the effects of HHD misplacements and unwanted foot's movements on the measurements. We used an optoelectronic system and a multicomponent load cell to quantify the sources of error in the manual assessment of the ankle strength due to both the operator's ability to hold still the HHD and the transversal components of the exerted force that are usually neglected in clinical routine. Results showed that foot's movements and angular misplacements of HHD on sagittal and horizontal planes were relevant sources of inaccuracy on the strength assessment. Moreover, ankle dorsiflexion and plantarflexion force measurements presented an inaccuracy less than 2% and higher than 10%, respectively. In conclusion, the manual use of a uniaxial HHD is not recommended for the assessment of ankle plantarflexion strength; on the contrary, it can be allowed asking the operator to pay strong attention to the HHD positioning in ankle dorsiflexion strength measurements.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] EVALUATION OF A HAND-HELD DYNAMOMETER FOR MEASURING MUSCLE STRENGTH UNDER FIELD CONDITIONS
    METCALF, WK
    STUBERG, WA
    JOURNAL OF PHYSIOLOGY-LONDON, 1986, 380 : P64 - P64
  • [22] Reliability of muscle strength measures obtained with a hand-held dynamometer in an elderly population
    Buckinx, Fanny
    Croisier, Jean-Louis
    Reginster, Jean-Yves
    Dardenne, Nadia
    Beaudart, Charlotte
    Slomian, Justine
    Leonard, Sylvain
    Bruyere, Olivier
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2017, 37 (03) : 332 - 340
  • [23] Strength assessment in postpolio syndrome: Validity of a hand-held dynamometer in detecting change
    Nollet, F
    Beelen, A
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1999, 80 (10): : 1316 - 1323
  • [24] COMPARATIVE STUDY ON THE ASSESSMENT OF THE STRENGTH OF THE KNEE EXTENSOR AND FLEXOR MUSCLES BY HAND-HELD DYNAMOMETER AND ISOKINETIC DYNAMOMETER
    Muff, Guillaume
    Masat, Julien
    Lecocq, Jehan
    Meyer, Alain
    Isner-Horobeti, Marie-Eve
    ACTA PHYSIOLOGICA, 2015, 214 : 46 - 46
  • [25] Intratester Reliability and Validity of Concentric Measurements Using a New Hand-Held Dynamometer
    Janssen, Jessie C.
    Le-Ngoc, Lan
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2009, 90 (09): : 1541 - 1547
  • [26] Responsiveness of measurements of lower-limb muscle strength obtained with a hand-held dynamometer from patients with stroke
    Bohannon, Richard W.
    Andrews, A. Williams
    Glenney, Susan Sullivan
    ISOKINETICS AND EXERCISE SCIENCE, 2013, 21 (02) : 129 - 134
  • [27] ASSESSMENT OF QUADRICEPS MUSCLE PERFORMANCE BY A HAND-HELD DYNAMOMETER AND AN ISOKINETIC DYNAMOMETER
    DEONES, VL
    WILEY, SC
    WORRELL, T
    JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 1994, 20 (06): : 296 - 301
  • [28] Reference Values for Cervical Muscle Strength in Healthy Women Using a Hand-Held Dynamometer and the Association with Age and Anthropometric Variables
    Gorla, Camila
    Martins, Tais de Souza
    Florencio, Lidiane Lima
    Pinheiro-Araujo, Carina Ferreira
    Fernandez-de-las-Penas, Cesar
    Martins, Jaqueline
    Bevilaqua-Grossi, Debora
    HEALTHCARE, 2023, 11 (16)
  • [29] Reliability of ankle dorsiflexion passive range of motion measurements obtained using a hand-held goniometer and Biodex dynamometer in stroke patients
    Jung, In-Gui
    Yu, Il-Young
    Kim, Soo-Yong
    Lee, Dong-Kyu
    Oh, Jae-Seop
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2015, 27 (06) : 1899 - 1901
  • [30] Reliability of a new stabilization device for measurement of muscle strength using a hand-held dynamometer
    Yasaci, Zeynal
    Argut, Sezen Karaborklu
    Celik, Derya
    MUSCLE & NERVE, 2024, 70 (06) : 1240 - 1246