On the closing sounds of a mechanical heart valve

被引:14
|
作者
Wu, CF
Herman, BA
Retta, SM
Grossman, LW
Liu, JS
Hwang, NHC
机构
[1] Florida Atlantic Univ, Coll Engn, Ctr Appl Stochast Res, Boca Raton, FL 33431 USA
[2] US FDA, Off Sci & Engn Labs, Ctr Devices & Radiol Hlth, Rockville, MD 20852 USA
[3] Natl Hlth Res Inst, Div Med Engn Res, Miaoli, Taiwan
基金
美国国家科学基金会;
关键词
mechanical heart valves; cavitation detection; cavitation noise; impact sound;
D O I
10.1007/s10439-005-3237-1
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In the 1994 Replacement Heart Valve Guidance of the U.S. Food and Drug Administration (FDA), in-vitro testing is required to evaluate the potential for cavitation damage of a mechanical heart valve (MHV). To fulfill this requirement, the stroboscopic high-speed imaging method is commonly used to visualize cavitation bubbles at the instant of valve closure. The procedure is expensive; it is also limited because not every cavitation event is detected, thus leaving the possibility of missing the whole cavitation process. As an alternative, some researchers have suggested an acoustic cavitation-detection method, based on the observation that cavitation noise has a broadband spectrum. In practice, however, it is difficult to differentiate between cavitation noise and the valve closing sound, which may also contain high-frequency components. In the present study, the frequency characteristics of the closing sound in air of a Bjork-Shiley Convexo-Concave (BSCC) valve are investigated. The occluder closing speed is used as a control parameter, which is measured via a laser sweeping technique. It is found that for the BSCC valve tested, the distribution of the sound energy over its frequency domain changes at different valve closing speeds, but the cut-off frequency remains unchanged at 123.32 +/- 6.12 kHz. The resonant frequencies of the occluder are also identified from the valve closing sound.
引用
收藏
页码:743 / 750
页数:8
相关论文
共 50 条
  • [21] Noise levels of closing sounds in vivo are equal for different bileaflet mechanical heart valves
    Johansen, P
    Hansen, SB
    Hasenkam, JM
    Nygaard, H
    JOURNAL OF HEART VALVE DISEASE, 2003, 12 (06): : 764 - 771
  • [22] MECHANICAL HEART SOUNDS
    不详
    LANCET, 1949, 257 (DEC17): : 1142 - 1142
  • [23] VALVE-CLOSING FUNCTION OF RIGHT ATRIUM - A STUDY OF PRESSURES AND ATRIAL SOUNDS IN PATIENTS WITH HEART BLOCK
    GRANT, C
    GREENE, DG
    BUNNELL, IL
    AMERICAN JOURNAL OF MEDICINE, 1963, 34 (03): : 325 - &
  • [24] A SQUEEZE FLOW PHENOMENON AT THE CLOSING OF A BILEAFLET MECHANICAL HEART-VALVE PROSTHESIS
    BLUESTEIN, D
    EINAV, S
    HWANG, NHC
    JOURNAL OF BIOMECHANICS, 1994, 27 (11) : 1369 - 1378
  • [25] Transient behavior analysis of a mechanical monoleaflet heart valve prosthesis in the closing phase
    Cheon, G.-J.
    Chandran, K.B.
    Journal of Biomechanical Engineering, 1994, 116 (04) : 452 - 459
  • [26] Modifying a tilting disk mechanical heart valve design to improve closing dynamics
    Herbertson, Luke H.
    Deutsch, Steven
    Manning, Keefe B.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2008, 130 (05):
  • [27] SPECTRUM OF ARTIFICIAL VALVE HEART SOUNDS
    HARVEY, WP
    DELEON, AC
    HUFNAGEL, CA
    CIRCULATION, 1965, 32 (4S2) : 108 - &
  • [28] HEART SOUNDS AFTER VALVE REPLACEMENT
    LUISADA, AA
    RAFTERY, EB
    LUISADA, AA
    AMERICAN JOURNAL OF CARDIOLOGY, 1967, 20 (02): : 287 - &
  • [29] A new method for quantitative evaluation of perceived sounds from mechanical heart valve prostheses
    Johansen, P
    Riis, C
    Hasenkam, JM
    Paulsen, PK
    Nygaard, H
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2000, 214 (H1) : 121 - 128
  • [30] Numerical comparison of the closing dynamics of a new trileaflet and a bileaflet mechanical aortic heart valve
    Chi-Pei Li
    Po-Chien Lu
    Journal of Artificial Organs, 2012, 15 : 364 - 374