On the closing sounds of a mechanical heart valve

被引:14
|
作者
Wu, CF
Herman, BA
Retta, SM
Grossman, LW
Liu, JS
Hwang, NHC
机构
[1] Florida Atlantic Univ, Coll Engn, Ctr Appl Stochast Res, Boca Raton, FL 33431 USA
[2] US FDA, Off Sci & Engn Labs, Ctr Devices & Radiol Hlth, Rockville, MD 20852 USA
[3] Natl Hlth Res Inst, Div Med Engn Res, Miaoli, Taiwan
基金
美国国家科学基金会;
关键词
mechanical heart valves; cavitation detection; cavitation noise; impact sound;
D O I
10.1007/s10439-005-3237-1
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In the 1994 Replacement Heart Valve Guidance of the U.S. Food and Drug Administration (FDA), in-vitro testing is required to evaluate the potential for cavitation damage of a mechanical heart valve (MHV). To fulfill this requirement, the stroboscopic high-speed imaging method is commonly used to visualize cavitation bubbles at the instant of valve closure. The procedure is expensive; it is also limited because not every cavitation event is detected, thus leaving the possibility of missing the whole cavitation process. As an alternative, some researchers have suggested an acoustic cavitation-detection method, based on the observation that cavitation noise has a broadband spectrum. In practice, however, it is difficult to differentiate between cavitation noise and the valve closing sound, which may also contain high-frequency components. In the present study, the frequency characteristics of the closing sound in air of a Bjork-Shiley Convexo-Concave (BSCC) valve are investigated. The occluder closing speed is used as a control parameter, which is measured via a laser sweeping technique. It is found that for the BSCC valve tested, the distribution of the sound energy over its frequency domain changes at different valve closing speeds, but the cut-off frequency remains unchanged at 123.32 +/- 6.12 kHz. The resonant frequencies of the occluder are also identified from the valve closing sound.
引用
收藏
页码:743 / 750
页数:8
相关论文
共 50 条
  • [31] Numerical comparison of the closing dynamics of a new trileaflet and a bileaflet mechanical aortic heart valve
    Li, Chi-Pei
    Lu, Po-Chien
    JOURNAL OF ARTIFICIAL ORGANS, 2012, 15 (04) : 364 - 374
  • [32] CONTOURSONAGRAPHIC ANALYSIS OF HEART SOUNDS, MURMURS AND SOUNDS PRODUCED BY VALVE PROSTHESES
    AIGNER, A
    FORTSCHRITTE DER MEDIZIN, 1977, 95 (35) : 2162 - 2166
  • [33] Wavelet analysis of bileaflet mechanical valve sounds
    Sugiki, Hiroshi
    Shiiya, Norihiko
    Murashita, Toshifumi
    Kunihara, Takashi
    Matsuzaki, Kenji
    Kubota, Takehiro
    Matsui, Yoshiro
    Sugiki, Kenji
    JOURNAL OF ARTIFICIAL ORGANS, 2007, 10 (01) : 16 - 21
  • [34] Wavelet analysis of bileaflet mechanical valve sounds
    Hiroshi Sugiki
    Norihiko Shiiya
    Toshifumi Murashita
    Takashi Kunihara
    Kenji Matsuzaki
    Takehiro Kubota
    Yoshiro Matsui
    Kenji Sugiki
    Journal of Artificial Organs, 2007, 10 : 16 - 21
  • [35] COMMENTS ON THE ANALYSIS OF VALVE VIBRATIONS AND HEART SOUNDS
    MAZUMDAR, J
    HEARN, TC
    PHYSICS IN MEDICINE AND BIOLOGY, 1981, 26 (02): : 335 - 335
  • [36] A Single-opening&closing Valve Tester for Direct Measurement of Closing Volume of the Heart Valve
    Wang, Hao
    Cui, Zhan
    Zhou, Zhongxi
    He, Zhaoming
    CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2022, 13 (01) : 80 - 89
  • [37] STUDY OF PROSTHETIC HEART VALVE SOUNDS.
    Koymen, Hayrettin
    Altay, Bulent K.
    Ider, Y.Ziya
    IEEE Transactions on Biomedical Engineering, 1987, BME-34 (11) : 853 - 863
  • [38] A STUDY OF PROSTHETIC HEART-VALVE SOUNDS
    KOYMEN, H
    ALTAY, BK
    IDER, YZ
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1987, 34 (11) : 853 - 863
  • [39] A Single-opening&closing Valve Tester for Direct Measurement of Closing Volume of the Heart Valve
    Hao Wang
    Zhan Cui
    Zhongxi Zhou
    Zhaoming He
    Cardiovascular Engineering and Technology, 2022, 13 : 80 - 89
  • [40] Measurement of the closing behavior of the Bjork-Shiley monoleaflet mechanical heart valve with an electrohydraulic total artificial heart
    Lee, H
    Tsukiya, T
    Homma, A
    Taenaka, Y
    Tatsumi, E
    Takano, H
    ARTIFICIAL ORGANS, 2003, 27 (08) : 744 - 748