Glaucoma Medication and Quality of Life after Phacoemulsification Combined with a Xen Gel Stent

被引:5
|
作者
Pahljina, Christian [1 ]
Sarny, Stephanie [1 ]
Hoeflechner, Lukas [1 ]
Falb, Thomas [1 ]
Schliessleder, Gernot [1 ]
Lindner, Marlene [2 ]
Ivastinovic, Domagoj [1 ]
Mansouri, Kaweh [3 ]
Lindner, Ewald [1 ]
机构
[1] Med Univ Graz, Dept Ophthalmol, A-8036 Graz, Austria
[2] Med Univ Graz, Dept Dent, A-8036 Graz, Austria
[3] Swiss Visio, Glaucoma Res Ctr, Montchoisi Clin, CH-1006 Lausanne, Switzerland
关键词
glaucoma; quality of life; surveys and questionnaires; minimal invasive glaucoma surgery; Xen gel stent; OCULAR SURFACE DISEASE; DRY EYE; SYMPTOM SCALE; PATIENT SATISFACTION; VISUAL-ACUITY; PREVALENCE; VALIDATION; TRIAL;
D O I
10.3390/jcm11123450
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Glaucoma has a significant impact on quality of life. Here, we aimed to evaluate the influence of a reduction in glaucoma medications on quality of life and patient satisfaction after phacoemulsification combined with the Xen gel stent. We carried out a cross-sectional survey of patients who underwent phacoemulsification with the Xen gel stent at the Medical University of Graz, Austria. Quality of life was assessed using the German version of the Glaucoma Symptoms Scale (GSS)-questionnaire. Patients were also asked whether the operation reduced glaucoma medications and to indicate their overall satisfaction from 1 (totally discontented) up to 10 (totally contented). Questionnaires of 80 patients were evaluated. A total of 36 patients (45.0%) reported a reduction in glaucoma medications. Three items of the GSS were significantly better in patients who needed fewer glaucoma medications after the operation ("hard to see in daylight", 75.0 +/- 31.1 vs. 57.7 +/- 39.1, p = 0.035; "hard to see in dark places", 81.1 +/- 28.7 vs. 54.9 +/- 41.2, p = 0.002; and "halos around lights", 88.3 +/- 25.9 vs. 68.8 +/- 38.6, p = 0.002). Patient satisfaction was significantly higher when the procedure led to a reduction in glaucoma medication (8.3 +/- 2.0 vs. 6.8 +/- 3.1; p = 0.034). The reported quality of life and patient satisfaction were significantly better when phacoemulsification with the Xen gel stent reduced the number of glaucoma medications needed.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] The efficacy of XEN gel stent implantation in glaucoma: a systematic review and meta-analysis
    Yang, Xiang
    Zhao, Yang
    Zhong, Yu
    Duan, Xuanchu
    BMC OPHTHALMOLOGY, 2022, 22 (01)
  • [42] XEN Gel Stent Implantation in Eyes With Previous Glaucoma Filtering Surgeries: A Case Series
    Vieira, Rita
    Leite, Joao
    Figueiredo, Ana
    Reis, Rita
    Sampaio, Isabel
    Meneres, Maria Joao
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (12)
  • [43] Evaluation of the XEN45 Gel Stent in Patients with Primary Angle Closure Glaucoma
    Millan, Francisco
    Reveron, Maria E.
    Gonzalez, Lilian
    Siso, Miguel
    Suescum, Carelys
    Novack, Gary D.
    Lee, Susan S.
    Vera, Vanessa
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [44] Efficacy and safety of XEN 45 gel stent alone or in combination with phacoemulsification in advanced open angle glaucoma patients: 1-year retrospective study
    Teresa Laborda-Guirao
    Juan M Cubero-Parra
    Antonio Hidalgo-Torres
    International Journal of Ophthalmology, 2020, (08) : 1250 - 1256
  • [45] The efficacy of XEN gel stent implantation in glaucoma: a systematic review and meta-analysis
    Xiang Yang
    Yang Zhao
    Yu Zhong
    Xuanchu Duan
    BMC Ophthalmology, 22
  • [46] Efficacy and safety of XEN 45 gel stent alone or in combination with phacoemulsification in advanced open angle glaucoma patients: 1-year retrospective study
    Laborda-Guirao, Teresa
    Cubero-Parra, Juan M.
    Hidalgo-Torres, Antonio
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2020, 13 (08) : 1250 - 1256
  • [47] Complications Following XEN45 Gel Stent and Glaucoma Drainage Device Implantation During Glaucoma Fellowship
    Lentz, P. Connor
    Wagner, Isabella V.
    Draper, Christian
    Ang, Bryan
    Boopathiraj, Nithya
    Miller, Darby
    Dorairaj, Syril
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (07)
  • [48] Intraocular Pressure and Medication Changes Associated with Xen Gel Stent: A Systematic Review of the Literature
    Panarelli, Joseph F.
    Vera, Vanessa
    Sheybani, Arsham
    Radcliffe, Nathan
    Fiscella, Richard
    Francis, Brian A.
    Smith, Oluwatosin U.
    Noecker, Robert J.
    CLINICAL OPHTHALMOLOGY, 2023, 17 : 25 - 46
  • [49] Ab-Externo Implantation of XEN Gel Stent for Refractory Steroid-Induced Glaucoma After Lamellar Keratoplasty
    Tan, Shu Yu
    Din, Norshamsiah Md
    Khialdin, Safinaz Mohd
    Halim, Wan Haslina Wan Abdul
    Tang, Seng Fai
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (02)
  • [50] XEN45 Gel Stent Combined with Healaflow Injectable Viscoelastic Implant
    Villarreal, Eloy
    Berkowitz, Eran
    Tiosano, Beatrice
    CASE REPORTS IN OPHTHALMOLOGICAL MEDICINE, 2023, 2023