The efficacy of XEN gel stent implantation in glaucoma: a systematic review and meta-analysis

被引:15
|
作者
Yang, Xiang [1 ]
Zhao, Yang [1 ]
Zhong, Yu [1 ,2 ]
Duan, Xuanchu [1 ,2 ]
机构
[1] Changsha Aier Eye Hosp, Changsha, Hunan, Peoples R China
[2] Cent South Univ, Aier Sch Ophthalmol, Changsha, Hunan, Peoples R China
关键词
Minimally invasive glaucoma surgery; XEN; Meta-analysis; OPEN-ANGLE GLAUCOMA; AB INTERNO; INTRAOCULAR-PRESSURE; SUCCESS RATES; SURGERY; OUTCOMES; SAFETY; CONJUNCTIVA; QUALITY; EYES;
D O I
10.1186/s12886-022-02502-y
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background Xen is a device for minimally invasive glaucoma surgery, and is used to treat POAG, pseudoexfoliative or pigmentary glaucoma, as well as refractory glaucoma. The efficacy of XEN in treating glaucoma remains to be confirmed and clarified. Hence, we conducted a systematic review and meta-analysis to examine the efficacy and associated complication of XEN implantations. Methods We conducted a literature search in PubMed, EMBASE, the Cochrane Library of Systematic Reviews, Web of Science, China National Knowledge Infrastructure, WanFang and SinoMed databases to identify studies, published before May 15, 2021, which evaluated XEN in glaucoma, and parameters for measurements included intra-ocular pressure (IOP), number of anti-glaucoma medications (NOAM), and bleb needling rate. We compared the measurements of XEN-only procedure between phaco-XEN and trabeculectomy, and we also did sub-analysis based on time points, glaucoma types, ethnics, etc. Sensitivity analyses and publication bias were conducted for evaluating bias.This study followed the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA 2020) reporting guideline. Results We identified 78 eligible studies, analysis revealed obvious IOP reduction after XEN stent implantation (SMD: 1.69, 95% CI 1.52 to 1.86, p value < 0.001) and NOAM reduction (SMD: 2.11, 95% CI 1.84 to 2.38, p value < 0.001). Sub-analysis showed no significant difference with respect to time points, ethnicities, and economic status. No significant difference was found between XEN treatment effect on POAG and PEXG eyes and between pseudo-phakic and phakic eyes. Also no significant difference was found between XEN and phaco-XEN surgery in terms of IOP after surgery (SMD: -0.01, 95% CI -0.09 to 0.08, p value 0.894). However, NOAM (after publication bias correction) and bleb needling rate (RR: 1.45, 95% CI 1.06to 1.99, p value 0.019) were lower in phaco-XEN group compared to XEN only group. Compared to trabeculectomy, XEN implantation had similar after-surgery IOP, however bleb needling rate (RR: 2.42, 95% CI 1.33 to 4.43, p value 0.004) was higher. Conclusion Our results confirmed that XEN is effective in lowering both IOP and NOAM till 48 months after surgery. It is noteworthy that XEN implantation leads to higher needling rate, compared to phaco-XEN or trabeculectomy. Further research, studying complications of XEN on non-European ethnicities, especially on Asian, are in urgent need before XEN is widely applied.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] The efficacy of XEN gel stent implantation in glaucoma: a systematic review and meta-analysis
    Xiang Yang
    Yang Zhao
    Yu Zhong
    Xuanchu Duan
    BMC Ophthalmology, 22
  • [2] The Outcomes of XEN Gel Stent Implantation: A Systematic Review and Meta-Analysis
    Chen, Xuan-zhu
    Liang, Zhi-qiao
    Yang, Kang-yi
    Lv, Kun
    Ma, Yao
    Li, Meng-yang
    Wu, Hui-juan
    FRONTIERS IN MEDICINE, 2022, 9
  • [3] Complications of XEN gel stent implantation for the treatment of glaucoma: a systematic review
    Gan, Lu
    Wang, Lixiang
    Chen, Jun
    Tang, Li
    FRONTIERS IN MEDICINE, 2024, 11
  • [4] Standalone XEN45 Gel Stent implantation in the treatment of open-angle glaucoma: A systematic review and meta-analysis
    Lim, Sheng Yang
    Betzler, Bjorn Kaijun
    Yip, Leonard Wei Leon
    Dorairaj, Syril
    Ang, Bryan Chin Hou
    SURVEY OF OPHTHALMOLOGY, 2022, 67 (04) : 1048 - 1061
  • [5] XEN gel implant with or without phacoemulsification for glaucoma: a systematic review and meta-analysis
    Wang, Bo
    Leng, Xiangjie
    An, Xuemei
    Zhang, Xiwen
    Liu, Xiang
    Lu, Xuejing
    ANNALS OF TRANSLATIONAL MEDICINE, 2020, 8 (20)
  • [6] Standalone XEN45 Gel Stent implantation versus combined XEN45-phacoemulsification in the treatment of open angle glaucoma—a systematic review and meta-analysis
    Sheng Yang Lim
    Bjorn Kaijun Betzler
    Leonard Wei Leon Yip
    Syril Dorairaj
    Bryan Chin Hou Ang
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2021, 259 : 3209 - 3219
  • [7] Efficacy of XEN gel stent implantation combined with mitomycin C injection in the treatment of open-angle glaucoma: a meta-analysis
    Feng, Hong
    Zhang, Zhonghong
    INTERNATIONAL OPHTHALMOLOGY, 2024, 44 (01)
  • [8] Standalone XEN45 Gel Stent implantation versus combined XEN45-phacoemulsification in the treatment of open angle glaucoma-a systematic review and meta-analysis
    Lim, Sheng Yang
    Betzler, Bjorn Kaijun
    Yip, Leonard Wei Leon
    Dorairaj, Syril
    Ang, Bryan Chin Hou
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2021, 259 (11) : 3209 - 3219
  • [9] Complications and post-operative interventions in XEN45 gel stent implantation in the treatment of open angle glaucoma—a systematic review and meta-analysis
    Bjorn Kaijun Betzler
    Sheng Yang Lim
    Boon Ang Lim
    Vivien Cherng Hui Yip
    Bryan Chin Hou Ang
    Eye, 2023, 37 : 1047 - 1060
  • [10] Complications and post-operative interventions in XEN45 gel stent implantation in the treatment of open angle glaucoma-a systematic review and meta-analysis
    Betzler, Bjorn Kaijun
    Lim, Sheng Yang
    Lim, Boon Ang
    Yip, Vivien Cherng Hui
    Ang, Bryan Chin Hou
    EYE, 2023, 37 (06) : 1047 - 1060