The efficacy of XEN gel stent implantation in glaucoma: a systematic review and meta-analysis

被引:15
|
作者
Yang, Xiang [1 ]
Zhao, Yang [1 ]
Zhong, Yu [1 ,2 ]
Duan, Xuanchu [1 ,2 ]
机构
[1] Changsha Aier Eye Hosp, Changsha, Hunan, Peoples R China
[2] Cent South Univ, Aier Sch Ophthalmol, Changsha, Hunan, Peoples R China
关键词
Minimally invasive glaucoma surgery; XEN; Meta-analysis; OPEN-ANGLE GLAUCOMA; AB INTERNO; INTRAOCULAR-PRESSURE; SUCCESS RATES; SURGERY; OUTCOMES; SAFETY; CONJUNCTIVA; QUALITY; EYES;
D O I
10.1186/s12886-022-02502-y
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background Xen is a device for minimally invasive glaucoma surgery, and is used to treat POAG, pseudoexfoliative or pigmentary glaucoma, as well as refractory glaucoma. The efficacy of XEN in treating glaucoma remains to be confirmed and clarified. Hence, we conducted a systematic review and meta-analysis to examine the efficacy and associated complication of XEN implantations. Methods We conducted a literature search in PubMed, EMBASE, the Cochrane Library of Systematic Reviews, Web of Science, China National Knowledge Infrastructure, WanFang and SinoMed databases to identify studies, published before May 15, 2021, which evaluated XEN in glaucoma, and parameters for measurements included intra-ocular pressure (IOP), number of anti-glaucoma medications (NOAM), and bleb needling rate. We compared the measurements of XEN-only procedure between phaco-XEN and trabeculectomy, and we also did sub-analysis based on time points, glaucoma types, ethnics, etc. Sensitivity analyses and publication bias were conducted for evaluating bias.This study followed the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA 2020) reporting guideline. Results We identified 78 eligible studies, analysis revealed obvious IOP reduction after XEN stent implantation (SMD: 1.69, 95% CI 1.52 to 1.86, p value < 0.001) and NOAM reduction (SMD: 2.11, 95% CI 1.84 to 2.38, p value < 0.001). Sub-analysis showed no significant difference with respect to time points, ethnicities, and economic status. No significant difference was found between XEN treatment effect on POAG and PEXG eyes and between pseudo-phakic and phakic eyes. Also no significant difference was found between XEN and phaco-XEN surgery in terms of IOP after surgery (SMD: -0.01, 95% CI -0.09 to 0.08, p value 0.894). However, NOAM (after publication bias correction) and bleb needling rate (RR: 1.45, 95% CI 1.06to 1.99, p value 0.019) were lower in phaco-XEN group compared to XEN only group. Compared to trabeculectomy, XEN implantation had similar after-surgery IOP, however bleb needling rate (RR: 2.42, 95% CI 1.33 to 4.43, p value 0.004) was higher. Conclusion Our results confirmed that XEN is effective in lowering both IOP and NOAM till 48 months after surgery. It is noteworthy that XEN implantation leads to higher needling rate, compared to phaco-XEN or trabeculectomy. Further research, studying complications of XEN on non-European ethnicities, especially on Asian, are in urgent need before XEN is widely applied.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] The role for the Xen gel stent implant in glaucoma treatment
    Stalmans, I.
    ACTA OPHTHALMOLOGICA, 2016, 94
  • [32] Cholesterol and glaucoma: a systematic review and meta-analysis
    Posch-Pertl, Laura
    Michelitsch, Monja
    Wagner, Gernot
    Wildner, Brigitte
    Silbernagel, Guenther
    Pregartner, Gudrun
    Wedrich, Andreas
    ACTA OPHTHALMOLOGICA, 2022, 100 (02) : 148 - 158
  • [33] Bilateral XEN Gel Stent Implantation in Juvenile-Onset Open-Angle Glaucoma
    Klug, Emma
    Sola-Del Valle, David
    CASE REPORTS IN OPHTHALMOLOGY, 2020, 11 (02): : 336 - 341
  • [34] Long-term efficacy and safety of XEN-45 gel stent implantation in patients with normal-tension glaucoma
    Nasyrov, Emil
    Gassel, Caroline J.
    Merle, David A.
    Neubauer, Jonas
    Voykov, Bogomil
    BMC OPHTHALMOLOGY, 2024, 24 (01)
  • [35] Efficacy and Safety of Dual Antiplatelet Therapy in Patients Undergoing Coronary Stent Implantation: A Systematic Review and Network Meta-Analysis
    Xu, Yi
    Shen, Yimin
    Chen, Delong
    Zhao, Pengfei
    Jiang, Jun
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2021, 2021
  • [36] Choroidal Detachment after XEN Gel Stent Implantation
    Cutolo, Carlo Alberto
    Negri, Letizia
    Olivari, Sara
    Cappelli, Francesca
    Traverso, Carlo Enrico
    Iester, Michele
    JOURNAL OF OPHTHALMOLOGY, 2021, 2021
  • [37] Efficacy of atosiban for repeated embryo implantation failure: A systematic review and meta-analysis
    Wang, Ruxin
    Huang, Haixia
    Tan, Yong
    Xia, Guicheng
    FRONTIERS IN ENDOCRINOLOGY, 2023, 14
  • [38] XEN® Gel Stent: A Comprehensive Review on Its Use as a Treatment Option for Refractory Glaucoma
    Fea, Antonio M.
    Durr, Georges M.
    Marolo, Paola
    Malinverni, Lorenza
    Economou, Mario A.
    Ahmed, Ike
    CLINICAL OPHTHALMOLOGY, 2020, 14 : 1805 - 1832
  • [39] Implantation of the XEN®45 Gel Stent in patients with glaucoma at a University Hospital - a retrospective quality control study
    Olsen, Lene Poder
    Ruhlmann, Peter Bruvik
    Vestergaard, Anders Hojslet
    ACTA OPHTHALMOLOGICA, 2021, 99 (06) : E968 - E969
  • [40] Double implantation of Xen 45 gel stent in primary open-angle glaucoma: a pilot study
    Grosso, Andrea
    Ceruti, Piero
    Garlasco, Jacopo
    Frohlich, Jacqueline
    Orione, Matteo
    Gugleta, Konstantin
    Fioretto, Mauro
    Calzetti, Giacomo
    INTERNATIONAL OPHTHALMOLOGY, 2024, 44 (01)