The efficacy of XEN gel stent implantation in glaucoma: a systematic review and meta-analysis

被引:15
|
作者
Yang, Xiang [1 ]
Zhao, Yang [1 ]
Zhong, Yu [1 ,2 ]
Duan, Xuanchu [1 ,2 ]
机构
[1] Changsha Aier Eye Hosp, Changsha, Hunan, Peoples R China
[2] Cent South Univ, Aier Sch Ophthalmol, Changsha, Hunan, Peoples R China
关键词
Minimally invasive glaucoma surgery; XEN; Meta-analysis; OPEN-ANGLE GLAUCOMA; AB INTERNO; INTRAOCULAR-PRESSURE; SUCCESS RATES; SURGERY; OUTCOMES; SAFETY; CONJUNCTIVA; QUALITY; EYES;
D O I
10.1186/s12886-022-02502-y
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background Xen is a device for minimally invasive glaucoma surgery, and is used to treat POAG, pseudoexfoliative or pigmentary glaucoma, as well as refractory glaucoma. The efficacy of XEN in treating glaucoma remains to be confirmed and clarified. Hence, we conducted a systematic review and meta-analysis to examine the efficacy and associated complication of XEN implantations. Methods We conducted a literature search in PubMed, EMBASE, the Cochrane Library of Systematic Reviews, Web of Science, China National Knowledge Infrastructure, WanFang and SinoMed databases to identify studies, published before May 15, 2021, which evaluated XEN in glaucoma, and parameters for measurements included intra-ocular pressure (IOP), number of anti-glaucoma medications (NOAM), and bleb needling rate. We compared the measurements of XEN-only procedure between phaco-XEN and trabeculectomy, and we also did sub-analysis based on time points, glaucoma types, ethnics, etc. Sensitivity analyses and publication bias were conducted for evaluating bias.This study followed the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA 2020) reporting guideline. Results We identified 78 eligible studies, analysis revealed obvious IOP reduction after XEN stent implantation (SMD: 1.69, 95% CI 1.52 to 1.86, p value < 0.001) and NOAM reduction (SMD: 2.11, 95% CI 1.84 to 2.38, p value < 0.001). Sub-analysis showed no significant difference with respect to time points, ethnicities, and economic status. No significant difference was found between XEN treatment effect on POAG and PEXG eyes and between pseudo-phakic and phakic eyes. Also no significant difference was found between XEN and phaco-XEN surgery in terms of IOP after surgery (SMD: -0.01, 95% CI -0.09 to 0.08, p value 0.894). However, NOAM (after publication bias correction) and bleb needling rate (RR: 1.45, 95% CI 1.06to 1.99, p value 0.019) were lower in phaco-XEN group compared to XEN only group. Compared to trabeculectomy, XEN implantation had similar after-surgery IOP, however bleb needling rate (RR: 2.42, 95% CI 1.33 to 4.43, p value 0.004) was higher. Conclusion Our results confirmed that XEN is effective in lowering both IOP and NOAM till 48 months after surgery. It is noteworthy that XEN implantation leads to higher needling rate, compared to phaco-XEN or trabeculectomy. Further research, studying complications of XEN on non-European ethnicities, especially on Asian, are in urgent need before XEN is widely applied.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] A case of mitomycin C toxicity after XEN gel stent implantation with the XEN air technique in a glaucoma patient
    Baeg, Joon Young
    Choi, Han Sol
    Lee, Si Hyung
    BMC OPHTHALMOLOGY, 2023, 23 (01)
  • [22] XEN Gel Stent Implantation in Eyes With Previous Glaucoma Filtering Surgeries: A Case Series
    Vieira, Rita
    Leite, Joao
    Figueiredo, Ana
    Reis, Rita
    Sampaio, Isabel
    Meneres, Maria Joao
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (12)
  • [23] Comparison of tube shunt implantation and trabeculectomy for glaucoma: a systematic review and meta-analysis
    Luo, Nachuan
    Liu, Miaowen
    Hao, Meiqi
    Xu, Ruoxin
    Wang, Fei
    Zhang, Wenxiong
    BMJ OPEN, 2023, 13 (04):
  • [24] Efficacy and economic analysis of Ex-PRESS implantation versus trabeculectomy in uncontrolled glaucoma: a systematic review and Meta-analysis
    Ling Wang
    Fang Sha
    Da-Dong Guo
    Hong-Sheng Bi
    Jun-Kang Si
    Yu-Xiang Du
    Kai Tang
    International Journal of Ophthalmology, 2016, 9 (01) : 124 - 131
  • [25] Efficacy and economic analysis of Ex-PRESS implantation versus trabeculectomy in uncontrolled glaucoma: a systematic review and Meta-analysis
    Wang, Ling
    Sha, Fang
    Guo, Da-Dong
    Bi, Hong-Sheng
    Si, Jun-Kang
    Du, Yu-Xiang
    Tang, Kai
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2016, 9 (01) : 124 - 131
  • [26] Budget impact analysis of the XEN® gel stent implant for glaucoma treatment
    Maria Martinez-de-la-Casa, Jose
    Amaro-Barra, Aida
    Angel Teus, Miguel
    Vila-Arteaga, Jorge
    Oyaguez, Itziar
    Martinez, Concha
    EXPERT REVIEW OF OPHTHALMOLOGY, 2019, 14 (01) : 5 - 13
  • [27] Efficacy of Needling Revision After XEN Gel Stent Implantation: A Prospective Study
    Midha, Neha
    Gillmann, Kevin
    Chaudhary, Ankita
    Mermoud, Andre
    Mansouri, Kaweh
    JOURNAL OF GLAUCOMA, 2020, 29 (01) : 11 - 14
  • [28] Efficacy and safety of dapsone gel for acne: a systematic review and meta-analysis
    Wang, Xuesong
    Wang, Zhenzhen
    Sun, Lulu
    Liu, Hong
    Zhang, Furen
    ANNALS OF PALLIATIVE MEDICINE, 2022, 11 (02) : 611 - 620
  • [29] XEN® Gel Stent for management of chronic open angle glaucoma: A review of the literature
    Buffault, J.
    Baudouin, C.
    Labbe, A.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2019, 42 (02): : E37 - E46
  • [30] Complications Following XEN45 Gel Stent and Glaucoma Drainage Device Implantation During Glaucoma Fellowship
    Lentz, P. Connor
    Wagner, Isabella V.
    Draper, Christian
    Ang, Bryan
    Boopathiraj, Nithya
    Miller, Darby
    Dorairaj, Syril
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (07)