Intraocular Pressure and Medication Changes Associated with Xen Gel Stent: A Systematic Review of the Literature

被引:6
|
作者
Panarelli, Joseph F. [1 ,9 ]
Vera, Vanessa [2 ]
Sheybani, Arsham [3 ]
Radcliffe, Nathan [4 ]
Fiscella, Richard [2 ]
Francis, Brian A. [5 ]
Smith, Oluwatosin U. [6 ]
Noecker, Robert J. [7 ,8 ]
机构
[1] New York Univ, Dept Ophthalmol, New York, NY USA
[2] AbbVie Co, Allergan, Dublin, Ireland
[3] Washington Univ St Louis, Sch Med, Dept Ophthalmol & Visual Sci, St Louis, MO USA
[4] New York Eye & Ear Infirm, Dept Ophthalmol, New York, NY USA
[5] Univ Calif Los Angeles, Doheny Eye Inst, Dept Ophthalmol, Los Angeles, CA USA
[6] Glaucoma Associates Texas, Dallas, TX USA
[7] Yale Sch Med, Dept Ophthalmol & Visual Sci, New Haven, CT USA
[8] Ophthalm Consultants Connecticut, Fairfield, CT USA
[9] New York Univ, Dept Ophthalmol, 222 E 41st St,3rd Floor, New York, NY 10017 USA
来源
CLINICAL OPHTHALMOLOGY | 2023年 / 17卷
关键词
glaucoma; glaucoma surgery; bleb; Xen; gel stent; OPEN-ANGLE GLAUCOMA; AB INTERNO; CATARACT-SURGERY; CLINICAL-OUTCOMES; NEEDLING REVISION; BLEB MORPHOLOGY; SUCCESS RATES; RISK-FACTORS; IMPLANTATION; EFFICACY;
D O I
10.2147/OPTH.S390955
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The Xen gel stent (Allergan Inc, an AbbVie company; Dublin, Ireland) was conceived as an option for patients requiring modest IOP reduction but for whom trabeculectomy was not yet indicated. As with any glaucoma surgery, establishing criteria for patient selection and identifying factors that contribute to a high likelihood of success are important. To help guide clinical decision-making, a systematic review of published studies on the gel stent was performed, with the goal of understanding postoperative outcomes based on clinical and patient factors. Results were organized around a series of pertinent clinical questions based on scenarios encountered in clinical practice. Criteria for including studies were intentionally broad, with the objective of simulating the diverse population of glaucoma patients encountered in real-world practice. Outcomes for IOP and medication reduction postopera-tively were assessed in various analyses, including in eyes with various glaucoma types and severity; in eyes naive to surgery as well as those with a history of prior incisional glaucoma surgery; and when surgery was performed as a standalone procedure or at the time of cataract surgery. The results of each of the various analyses were consistent in demonstrating that successful gel stent surgery achieved a postoperative IOP of approximately 14.0 mm Hg and reduction to fewer than 1 glaucoma medication. Additional data are shown on outcomes by method of implant (ab interno vs ab externo); intraoperative use of antifibrotics; and rates of needling in published studies.
引用
收藏
页码:25 / 46
页数:22
相关论文
共 50 条
  • [1] Effectiveness and Safety of Xen Gel Stent in Glaucoma Surgery: A Systematic Review of the Literature
    Traverso, Carlo Enrico
    Carassa, Roberto
    Fea, Antonio Maria
    Figus, Michele
    Astarita, Carlo
    Piergentili, Benedetta
    Vera, Vanessa
    Gandolfi, Stefano
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (16)
  • [2] Bleb Associated Xen Gel Stent Endophthalmitis: A Case Report and Review of Literature
    Dilip, Mridula
    Koretz, Zachary
    Paez-Escamilla, Manuel A.
    Hughes, Emily
    Sahel, Jose-Alain
    Conner, Ian
    Errera, Marie-Helene
    OCULAR IMMUNOLOGY AND INFLAMMATION, 2023, 31 (07) : 1533 - 1536
  • [3] Efficacy of the XEN gel stent on intraocular pressure lowering in East Asian eyes
    Hu, Jeremy Y.
    Ang, Bryan C. H.
    Yip, Leonard W.
    INTERNATIONAL OPHTHALMOLOGY, 2020, 40 (05) : 1191 - 1199
  • [4] Efficacy of the XEN gel stent on intraocular pressure lowering in East Asian eyes
    Jeremy Y. Hu
    Bryan C. H. Ang
    Leonard W. Yip
    International Ophthalmology, 2020, 40 : 1191 - 1199
  • [5] Complications of XEN gel stent implantation for the treatment of glaucoma: a systematic review
    Gan, Lu
    Wang, Lixiang
    Chen, Jun
    Tang, Li
    FRONTIERS IN MEDICINE, 2024, 11
  • [6] XEN® Gel Stent for management of chronic open angle glaucoma: A review of the literature
    Buffault, J.
    Baudouin, C.
    Labbe, A.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2019, 42 (02): : E37 - E46
  • [7] Review of the Xen Gel Stent and InnFocus MicroShunt
    Green, Wesley
    Lind, John T.
    Sheybani, Arsham
    CURRENT OPINION IN OPHTHALMOLOGY, 2018, 29 (02) : 162 - 170
  • [8] The Outcomes of XEN Gel Stent Implantation: A Systematic Review and Meta-Analysis
    Chen, Xuan-zhu
    Liang, Zhi-qiao
    Yang, Kang-yi
    Lv, Kun
    Ma, Yao
    Li, Meng-yang
    Wu, Hui-juan
    FRONTIERS IN MEDICINE, 2022, 9
  • [9] Recommendations for the management of elevated intraocular pressure due to bleb fibrosis after XEN gel stent implantation
    Vera, Vanessa
    Sheybani, Arsham
    Lindfield, Dan
    Stalmans, Ingeborg
    Ahmed, Iqbal Ike K.
    CLINICAL OPHTHALMOLOGY, 2019, 13 : 685 - 694
  • [10] Long-term efficacy of Xen gel stent in controlling intraocular pressure in open angle glaucoma
    March, Elizabeth
    Mosongo, Rodney
    Lee, James
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)