Intraocular Pressure and Medication Changes Associated with Xen Gel Stent: A Systematic Review of the Literature

被引:6
|
作者
Panarelli, Joseph F. [1 ,9 ]
Vera, Vanessa [2 ]
Sheybani, Arsham [3 ]
Radcliffe, Nathan [4 ]
Fiscella, Richard [2 ]
Francis, Brian A. [5 ]
Smith, Oluwatosin U. [6 ]
Noecker, Robert J. [7 ,8 ]
机构
[1] New York Univ, Dept Ophthalmol, New York, NY USA
[2] AbbVie Co, Allergan, Dublin, Ireland
[3] Washington Univ St Louis, Sch Med, Dept Ophthalmol & Visual Sci, St Louis, MO USA
[4] New York Eye & Ear Infirm, Dept Ophthalmol, New York, NY USA
[5] Univ Calif Los Angeles, Doheny Eye Inst, Dept Ophthalmol, Los Angeles, CA USA
[6] Glaucoma Associates Texas, Dallas, TX USA
[7] Yale Sch Med, Dept Ophthalmol & Visual Sci, New Haven, CT USA
[8] Ophthalm Consultants Connecticut, Fairfield, CT USA
[9] New York Univ, Dept Ophthalmol, 222 E 41st St,3rd Floor, New York, NY 10017 USA
来源
CLINICAL OPHTHALMOLOGY | 2023年 / 17卷
关键词
glaucoma; glaucoma surgery; bleb; Xen; gel stent; OPEN-ANGLE GLAUCOMA; AB INTERNO; CATARACT-SURGERY; CLINICAL-OUTCOMES; NEEDLING REVISION; BLEB MORPHOLOGY; SUCCESS RATES; RISK-FACTORS; IMPLANTATION; EFFICACY;
D O I
10.2147/OPTH.S390955
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The Xen gel stent (Allergan Inc, an AbbVie company; Dublin, Ireland) was conceived as an option for patients requiring modest IOP reduction but for whom trabeculectomy was not yet indicated. As with any glaucoma surgery, establishing criteria for patient selection and identifying factors that contribute to a high likelihood of success are important. To help guide clinical decision-making, a systematic review of published studies on the gel stent was performed, with the goal of understanding postoperative outcomes based on clinical and patient factors. Results were organized around a series of pertinent clinical questions based on scenarios encountered in clinical practice. Criteria for including studies were intentionally broad, with the objective of simulating the diverse population of glaucoma patients encountered in real-world practice. Outcomes for IOP and medication reduction postopera-tively were assessed in various analyses, including in eyes with various glaucoma types and severity; in eyes naive to surgery as well as those with a history of prior incisional glaucoma surgery; and when surgery was performed as a standalone procedure or at the time of cataract surgery. The results of each of the various analyses were consistent in demonstrating that successful gel stent surgery achieved a postoperative IOP of approximately 14.0 mm Hg and reduction to fewer than 1 glaucoma medication. Additional data are shown on outcomes by method of implant (ab interno vs ab externo); intraoperative use of antifibrotics; and rates of needling in published studies.
引用
收藏
页码:25 / 46
页数:22
相关论文
共 50 条
  • [21] Intraocular Degradation of XEN45 Gel Stent 3 Years After its Implantation
    Widder, Randolf A.
    Kuehnrich, Pia
    Hild, Matthias
    Rennings, Corinna
    Szumniak, Alexander
    Roessler, Gernot F.
    JOURNAL OF GLAUCOMA, 2019, 28 (12) : E171 - E173
  • [22] Severe Intraocular Pressure Elevation After Intracameral Healon 5 Viscoelastic Support for Postoperative Hypotony After XEN Gel Stent Insertion
    Bruynseels, Alice
    Sii, Freda
    Masood, Imran
    Shah, Peter
    JOURNAL OF GLAUCOMA, 2018, 27 (04) : E75 - E76
  • [23] Early Postoperative Intraocular Pressure is Associated With Better Pressure Control After XEN Implantation
    Cutolo, Carlo A.
    Iester, Michele
    Bagnis, Alessandro
    Bonzano, Chiara
    Negri, Letizia
    Olivari, Sara
    Cappelli, Francesca
    Testa, Valeria
    Sindaco, Daniele
    Pizzorno, Chiara
    Scotto, Riccardo
    Saccheggiani, Michela
    Traverso, Carlo E.
    JOURNAL OF GLAUCOMA, 2020, 29 (06) : 456 - 460
  • [24] Posture-induced changes in intraocular pressure after ab externo XEN45 gel-stent implantation in patients with primary open-angle glaucoma
    Jin, Hyung Nam
    Nam, Jeong Woo
    Zhang, Haowei
    Sung, Mi Sun
    Park, Sang Woo
    BMC OPHTHALMOLOGY, 2022, 22 (01)
  • [25] Posture-induced changes in intraocular pressure after ab externo XEN45 gel-stent implantation in patients with primary open-angle glaucoma
    Hyung Nam Jin
    Jeong Woo Nam
    Haowei Zhang
    Mi Sun Sung
    Sang Woo Park
    BMC Ophthalmology, 22
  • [26] Relationship between the location of the XEN® stent glaucoma implant (with respect to the Tenon capsule) and the intraocular pressure
    Figueroa-Vercellino, J. P.
    Peraza-Nieves, J. E.
    Milla, E.
    Pazos, M.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2019, 42 (04): : 421 - 422
  • [27] XEN® Gel Stent: A Comprehensive Review on Its Use as a Treatment Option for Refractory Glaucoma
    Fea, Antonio M.
    Durr, Georges M.
    Marolo, Paola
    Malinverni, Lorenza
    Economou, Mario A.
    Ahmed, Ike
    CLINICAL OPHTHALMOLOGY, 2020, 14 : 1805 - 1832
  • [28] XEN Gel Stent to Treat Intraocular Hypertension After Dexamethasone-Implant Intravitreal Injections: 5 Cases
    Rezkallah, Amina
    Mathis, Thibaud
    Denis, Philippe
    Kodjikian, Laurent
    JOURNAL OF GLAUCOMA, 2019, 28 (01) : E5 - E9
  • [29] XEN Gel Stent to Treat Intraocular Hypertension After Dexamethasone-Implant Intravitreal Injections: 5 Cases
    Rezkallah, Amina
    Mathis, Thibaud
    Denis, Philippe
    Kodjikian, Laurent
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [30] Corneal and intraocular pressure changes associated to the circadian rhythms: a narrative review
    Barberan-Bernardos, Laura
    Ariza-Gracia, Miguel Angel
    Pinero, David P.
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2024, 17 (10) : 1921 - 1928