Scatter Correction Requirements for Likelihood-Based Attenuation Artifact Correction in PET

被引:5
|
作者
Laymon, C. M. [1 ]
Bowsher, J. E. [2 ]
Carney, J. P. J. [1 ]
Blodgett, T. M. [1 ]
机构
[1] Univ Pittsburgh, Pittsburgh, PA 15260 USA
[2] Duke Univ, Durham, NC 27706 USA
来源
2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6 | 2006年
关键词
Positron emission tomography; Xray tomography; Image reconstruction; Attenuation measurement;
D O I
10.1109/NSSMIC.2006.354340
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Artifacts have been observed in CT-based, 511keV attenuation images for PET attenuation correction. Artifact detection and correction algorithms are being developed based on the Poisson loglikelihood function (LLF). The LLF quantifies the level of consistency between an activity and attenuation image pair and the measured emission sinogram. We have shown that the LLF can discriminate more-artifactual from less-artifactual attenuation images at clinical noise levels. Here we use a digital anthropomorphic phantom to examine the effect of scatter on LLF performance. Base sinograms were formed by forward projecting a true activity distribution through a true attenuation distribution. Scatter was simulated by filtering the base sinograms. Noise was considered by producing 128 Poisson-randomized variates of the filtered base sinograms for each of 7 assumed count levels. An artifactual attenuation image was produced by modifying mu-values of regions of the true attenuation image. For each sinogram, two OSEM reconstructions were performed and two LLF values obtained using the artifactual and true attenuation. Accuracy was calculated as the fraction of cases in which the LLF preferred the artifact-free attenuation image. Additional studies were performed to test several scatter correction procedures. Findings show that scatter may render the LLF unreliable even in the limit of high-count scans but that its usefulness is restored by applying an appropriate correction.
引用
收藏
页码:2151 / 2154
页数:4
相关论文
共 50 条
  • [41] Emission based attenuation correction of PET images of the thorax
    Madsen, MT
    Lee, JR
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 967 - 971
  • [42] MRI based attenuation correction for brain PET images
    Kops, Elena Rota
    Qin, Peng
    Mueller-Veggian, Mattea
    Herzog, Hans
    ADVANCES IN MEDICAL ENGINEERING, 2007, 114 : 93 - +
  • [43] Sinogram-based attenuation correction in PET/CT
    Yang, Qingsong
    Lu, Yang
    Xi, Yan
    Cong, Wenxiang
    Kalra, Mannudeep
    Wang, Ge
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2016, 24 (01) : 9 - 22
  • [44] CT Based Attenuation Correction for PET Brain Imaging
    Lokitz, Stephen J.
    Coleman, R. Edward
    Yoshizumi, Terry T.
    Toncheva, Greta I.
    Daigle, Lauren T.
    Colsher, James G.
    Turkington, Timothy G.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3320 - 3325
  • [45] A Patch-based CBCT Scatter Artifact Correction Using Prior CT
    Yang, Xiaofeng
    Liu, Tian
    Dong, Xue
    Tang, Xiangyang
    Elder, Eric
    Curran, Walter J.
    Dhabaan, Anees
    MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132
  • [46] Scatter and attenuation correction for In-111 based on energy spectrum fitting
    Kaplan, MS
    Miyaoka, RS
    Kohlmyer, SK
    Haynor, DR
    Harrison, RL
    Lewellen, TK
    MEDICAL PHYSICS, 1996, 23 (07) : 1277 - 1285
  • [47] Absolute radioactivity quantification using transmission based scatter and attenuation correction
    Bailey, DL
    Lewis, RE
    Clarke, GL
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (08): : 969 - 969
  • [48] Metal artifact reduction in CT-based attenuation correction of PET data using the virtual sinogram concept
    Abdoli, Mehrsima
    Ay, Mohammad Reza
    Ahmadian, Alireza
    Zaidi, Habib
    3rd International Conference on Bioinformatics and Biomedical Engineering, iCBBE 2009, 2009,
  • [49] Metal Artifact Reduction in CT-Based Attenuation Correction of PET Data Using the Virtual Sinogram Concept
    Abdoli, Mehrsima
    Ay, Mohammad Reza
    Ahmadian, Alireza
    Zaidi, Habib
    2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 1848 - +
  • [50] Empirical scatter correction: CBCT scatter artifact reduction without prior information
    Trapp, Philip
    Maier, Joscha
    Susenburger, Markus
    Sawall, Stefan
    Kachelriess, Marc
    MEDICAL PHYSICS, 2022, 49 (07) : 4566 - 4584