Scatter Correction Requirements for Likelihood-Based Attenuation Artifact Correction in PET

被引:5
|
作者
Laymon, C. M. [1 ]
Bowsher, J. E. [2 ]
Carney, J. P. J. [1 ]
Blodgett, T. M. [1 ]
机构
[1] Univ Pittsburgh, Pittsburgh, PA 15260 USA
[2] Duke Univ, Durham, NC 27706 USA
关键词
Positron emission tomography; Xray tomography; Image reconstruction; Attenuation measurement;
D O I
10.1109/NSSMIC.2006.354340
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Artifacts have been observed in CT-based, 511keV attenuation images for PET attenuation correction. Artifact detection and correction algorithms are being developed based on the Poisson loglikelihood function (LLF). The LLF quantifies the level of consistency between an activity and attenuation image pair and the measured emission sinogram. We have shown that the LLF can discriminate more-artifactual from less-artifactual attenuation images at clinical noise levels. Here we use a digital anthropomorphic phantom to examine the effect of scatter on LLF performance. Base sinograms were formed by forward projecting a true activity distribution through a true attenuation distribution. Scatter was simulated by filtering the base sinograms. Noise was considered by producing 128 Poisson-randomized variates of the filtered base sinograms for each of 7 assumed count levels. An artifactual attenuation image was produced by modifying mu-values of regions of the true attenuation image. For each sinogram, two OSEM reconstructions were performed and two LLF values obtained using the artifactual and true attenuation. Accuracy was calculated as the fraction of cases in which the LLF preferred the artifact-free attenuation image. Additional studies were performed to test several scatter correction procedures. Findings show that scatter may render the LLF unreliable even in the limit of high-count scans but that its usefulness is restored by applying an appropriate correction.
引用
收藏
页码:2151 / 2154
页数:4
相关论文
共 50 条
  • [21] Attenuation and scatter correction in fully 3D limited angle PET
    Pönisch, F
    Enghardt, W
    Lauckner, K
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 2115 - 2118
  • [22] A log likelihood based method for recovery of localized defects in PET attenuation-correction images
    Laymon, CM
    Bowsher, JE
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2710 - 2714
  • [23] Metal Artifact Reduction in CT-Based Attenuation Correction of PET using Sobolev Sinogram Restoration
    Mehranian, A.
    Ay, M. R.
    Rahmim, A.
    Zaidi, H.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2936 - 2942
  • [24] A Novel Approach for Reducing Dental Filling Artifact in CT-Based Attenuation Correction of PET Data
    Abdoli, M.
    Ay, M. R.
    Ahmadian, A.
    Sahba, N.
    Zaidi, H.
    4TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, 2009, 22 (1-3): : 492 - 495
  • [25] Scatter estimation and motion correction in PET
    Thielemans, Kris
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 1745 - 1747
  • [26] An Improved Technique for Scatter Correction in PET
    Lin, S.
    Wang, Y.
    Lue, K.
    Lin, H.
    Chuang, K.
    MEDICAL PHYSICS, 2014, 41 (06) : 131 - 131
  • [27] A SEGMENTED ATTENUATION CORRECTION FOR PET
    XU, EZ
    MULLANI, NA
    GOULD, KL
    ANDERSON, WL
    JOURNAL OF NUCLEAR MEDICINE, 1991, 32 (01) : 161 - 165
  • [28] Impact of attenuation correction, scatter correction and resolution recovery an cardiac SPECT
    Keng, F
    Chang, SM
    Salfity, M
    Verant, MS
    CIRCULATION, 1999, 100 (18) : 312 - 312
  • [29] Comparison of MR Based Attenuation Correction Methods with CT Based Attenuation Correction in Dynamic Brain PET imaging
    Firouzian, A.
    Delso, G.
    Hallett, W.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S695 - S696
  • [30] CT-based attenuation and scatter correction compared with uniform attenuation correction in brain perfusion SPECT imaging for dementia
    Gillen, Rebecca
    Firbank, Michael J.
    Lloyd, Jim
    O'Brien, John T.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (17): : 6775 - 6787