New prototype neuronavigation system based on preoperative imaging and intraoperative freehand ultrasound: system description and validation

被引:49
|
作者
Mercier, Laurence [1 ]
Del Maestro, Rolando F. [2 ]
Petrecca, Kevin [2 ]
Kochanowska, Anna [1 ]
Drouin, Simon [1 ]
Yan, Charles X. B. [1 ]
Janke, Andrew L. [3 ]
Chen, Sean Jy-Shyang [1 ]
Collins, D. Louis [1 ]
机构
[1] McGill Univ, Montreal Neurol Inst, McConnell Brain Imaging Ctr, Montreal, PQ, Canada
[2] McGill Univ, Montreal Neurol Hosp & Inst, Brain Tumour Res Ctr, Montreal, PQ, Canada
[3] Australian Natl Univ, Dept Geriatr Med, Canberra, SA, Australia
基金
加拿大健康研究院;
关键词
Application accuracy; Image-guided surgery; Intraoperative imaging; Intraoperative ultrasound; Neuronavigation; Registration; BRAIN-SHIFT; 3-D ULTRASOUND; 3D ULTRASOUND; GUIDED NEUROSURGERY; TUMOR RESECTION; 3-DIMENSIONAL ULTRASOUND; REGISTRATION; CALIBRATION; MRI; ACCURACY;
D O I
10.1007/s11548-010-0535-3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose The aim of this report is to present IBIS (Interactive Brain Imaging System) NeuroNav, a new prototype neuronavigation system that has been developed in our research laboratory over the past decade that uses tracked intraoperative ultrasound to address surgical navigation issues related to brain shift. The unique feature of the system is its ability, when needed, to improve the initial patient-to-preoperative image alignment based on the intraoperative ultrasound data. Parts of IBIS Neuronav source code are now publicly available on-line. Methods Four aspects of the system are characterized in this paper: the ultrasound probe calibration, the temporal calibration, the patient-to-image registration and the MRI-ultrasound registration. In order to characterize its real clinical precision and accuracy, the system was tested in a series of adult brain tumor cases. Results Three metrics were computed to evaluate the precision and accuracy of the ultrasound calibration. 1) Reproducibility: 1.77mm and 1.65mm for the bottom corners of the ultrasound image, 2) point reconstruction precision 0.62-0.90mm: and 3) point reconstruction accuracy: 0.49-0.74mm. The temporal calibration error was estimated to be 0.82 ms. The mean fiducial registration error (FRE) of the homologous-point-based patient-to-MRI registration for our clinical data is 4.9 +/- 1.1mm. After the skin landmark-based registration, the mean misalignment between the ultrasound and MR images in the tumor region is 6.1 +/- 3.4 mm. Conclusions The components and functionality of a new prototype system are described and its precision and accuracy evaluated. It was found to have an accuracy similar to other comparable systems in the literature.
引用
收藏
页码:507 / 522
页数:16
相关论文
共 50 条
  • [41] Automatic Diagnosis of Carotid Atherosclerosis Using a Portable Freehand 3-D Ultrasound Imaging System
    Li, Jiawen
    Huang, Yunqian
    Song, Sheng
    Chen, Hongbo
    Shi, Junni
    Xu, Duo
    Zhang, Haibin
    Chen, Man
    Zheng, Rui
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2024, 71 (02) : 266 - 279
  • [42] Multi-view 3D reconstruction with volumetric registration in a freehand ultrasound imaging system
    Yu, Honggang
    Pattichis, Marios S.
    Goens, M. Beth
    MEDICAL IMAGING 2006: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2006, 6147
  • [43] Functional Magnetic Resonance Imaging and Diffusion Tensor Tractography Incorporated Into an Intraoperative 3-Dimensional Ultrasound-Based Neuronavigation System: Impact on Therapeutic Strategies, Extent of Resection, and Clinical Outcome
    Berntsen, Erik Magnus
    Gulati, Sasha
    Solheim, Ole
    Kvistad, Kjell Arne
    Torp, Sverre Helge
    Selbekk, Tormod
    Unsgard, Geirmund
    Haberg, Asta K.
    NEUROSURGERY, 2010, 67 (02) : 251 - 264
  • [44] DESCRIPTION OF A PROTOTYPE EMISSION-TRANSMISSION COMPUTED-TOMOGRAPHY IMAGING-SYSTEM
    LANG, TF
    HASEGAWA, BH
    LIEW, SC
    BROWN, JK
    BLANKESPOOR, SC
    REILLY, SM
    GINGOLD, EL
    CANN, CE
    JOURNAL OF NUCLEAR MEDICINE, 1992, 33 (10) : 1881 - 1887
  • [45] Identification of the Facial Nerve in Relation to Vestibular Schwannoma Using Preoperative Diffusion Tensor Tractography and Intraoperative Tractography-Integrated Neuronavigation System
    Li, Huan
    Wang, Liang
    Hao, Shuyu
    Li, Da
    Wu, Zhen
    Zhang, Liwei
    Zhang, Junting
    WORLD NEUROSURGERY, 2017, 107 : 669 - 677
  • [46] The new Low Gap BPM system at ELETTRA: Description and prototype tests.
    Ferianis, M
    De Monte, R
    Gambitta, A
    Loda, G
    Pangos, N
    Boscolo, A
    Chianese, F
    Schlott, V
    Pollet, P
    Ursic, R
    BEAM INSTRUMENTATION WORKSHOP 2000, 2000, 546 : 356 - 364
  • [47] Intraoperative validation of a new system for invasive continuous cardiac output measurement
    Giuseppe D’Ancona
    Matteo Parrinello
    Gianluca Santise
    Domenico Biondo
    Francesco Pirone
    Sergio Sciacca
    Marco Turrisi
    Antonio Arcadipane
    Michele Pilato
    Intensive Care Medicine, 2009, 35 : 943 - 947
  • [48] Intraoperative validation of a new system for invasive continuous cardiac output measurement
    D'Ancona, Giuseppe
    Parrinello, Matteo
    Santise, Gianluca
    Biondo, Domenico
    Pirone, Francesco
    Sciacca, Sergio
    Turrisi, Marco
    Arcadipane, Antonio
    Pilato, Michele
    INTENSIVE CARE MEDICINE, 2009, 35 (05) : 943 - 947
  • [49] Flight Test Validation of Ground Based Augmentation System Prototype in Taiwan
    Lin, Yueh-Wen
    Sung, Yi-Ting
    Yeh, Shuo-Ju
    Jan, Shau-Shiun
    PROCEEDINGS OF THE 33RD INTERNATIONAL TECHNICAL MEETING OF THE SATELLITE DIVISION OF THE INSTITUTE OF NAVIGATION (ION GNSS+ 2020), 2020, : 1144 - 1152
  • [50] A New Shear Wave Imaging System for Ultrasound Elastography
    Qiu, Weibao
    Wang, Congzhi
    Xiao, Yang
    Qian, Ming
    Zheng, Hairong
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 3847 - 3850