New prototype neuronavigation system based on preoperative imaging and intraoperative freehand ultrasound: system description and validation

被引:49
|
作者
Mercier, Laurence [1 ]
Del Maestro, Rolando F. [2 ]
Petrecca, Kevin [2 ]
Kochanowska, Anna [1 ]
Drouin, Simon [1 ]
Yan, Charles X. B. [1 ]
Janke, Andrew L. [3 ]
Chen, Sean Jy-Shyang [1 ]
Collins, D. Louis [1 ]
机构
[1] McGill Univ, Montreal Neurol Inst, McConnell Brain Imaging Ctr, Montreal, PQ, Canada
[2] McGill Univ, Montreal Neurol Hosp & Inst, Brain Tumour Res Ctr, Montreal, PQ, Canada
[3] Australian Natl Univ, Dept Geriatr Med, Canberra, SA, Australia
基金
加拿大健康研究院;
关键词
Application accuracy; Image-guided surgery; Intraoperative imaging; Intraoperative ultrasound; Neuronavigation; Registration; BRAIN-SHIFT; 3-D ULTRASOUND; 3D ULTRASOUND; GUIDED NEUROSURGERY; TUMOR RESECTION; 3-DIMENSIONAL ULTRASOUND; REGISTRATION; CALIBRATION; MRI; ACCURACY;
D O I
10.1007/s11548-010-0535-3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose The aim of this report is to present IBIS (Interactive Brain Imaging System) NeuroNav, a new prototype neuronavigation system that has been developed in our research laboratory over the past decade that uses tracked intraoperative ultrasound to address surgical navigation issues related to brain shift. The unique feature of the system is its ability, when needed, to improve the initial patient-to-preoperative image alignment based on the intraoperative ultrasound data. Parts of IBIS Neuronav source code are now publicly available on-line. Methods Four aspects of the system are characterized in this paper: the ultrasound probe calibration, the temporal calibration, the patient-to-image registration and the MRI-ultrasound registration. In order to characterize its real clinical precision and accuracy, the system was tested in a series of adult brain tumor cases. Results Three metrics were computed to evaluate the precision and accuracy of the ultrasound calibration. 1) Reproducibility: 1.77mm and 1.65mm for the bottom corners of the ultrasound image, 2) point reconstruction precision 0.62-0.90mm: and 3) point reconstruction accuracy: 0.49-0.74mm. The temporal calibration error was estimated to be 0.82 ms. The mean fiducial registration error (FRE) of the homologous-point-based patient-to-MRI registration for our clinical data is 4.9 +/- 1.1mm. After the skin landmark-based registration, the mean misalignment between the ultrasound and MR images in the tumor region is 6.1 +/- 3.4 mm. Conclusions The components and functionality of a new prototype system are described and its precision and accuracy evaluated. It was found to have an accuracy similar to other comparable systems in the literature.
引用
收藏
页码:507 / 522
页数:16
相关论文
共 50 条
  • [31] PROTOTYPE OF 3D RECONSTRUCTION SYSTEM FOR ULTRASOUND IMAGING MODALITIES
    Rizqie, Muhammad Qurhanul
    Adiprawita, Widyawardana
    Mengko, Tati R.
    PROCEEDINGS OF 2013 3RD INTERNATIONAL CONFERENCE ON INSTRUMENTATION, COMMUNICATIONS, INFORMATION TECHNOLOGY, AND BIOMEDICAL ENGINEERING (ICICI-BME), 2013, : 21 - 26
  • [32] Instrumentation of off-the-shelf ultrasound system for measurement of probe forces during freehand imaging
    Schimmoeller, Tyler
    Colbrunn, Robb
    Nagle, Tara
    Lobosky, Mark
    Neumann, Erica E.
    Owings, Tammy M.
    Landis, Benjamin
    Jelovsek, J. Eric
    Erdemir, Ahmet
    JOURNAL OF BIOMECHANICS, 2019, 83 : 117 - 124
  • [33] Development of a three-dimensional freehand endorectal ultrasound system for use in rectal cancer imaging
    Warmath, JR
    Bao, P
    Clements, LW
    Herline, AJ
    Galloway, RL
    MEDICAL PHYSICS, 2005, 32 (06) : 1757 - 1766
  • [34] 3D Anatomical Investigation of Achilles Tendon Using a Freehand Ultrasound Imaging System
    Gao, Fan
    2010 4TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING (ICBBE 2010), 2010,
  • [35] Performance of a Prototype Universal Camera Based Imaging System
    Back, J.
    Park, S.
    MEDICAL PHYSICS, 2018, 45 (06) : E194 - E194
  • [36] Development and evaluation of a prototype detector for an intraoperative laparoscopic coincidence imaging system with PET tracers
    Liyanaarachchi, Madhushanka R.
    Shimazoe, Kenji
    Takahashi, Hiroyuki
    Nakagawa, Keiichi
    Kobayashi, Etsuko
    Sakuma, Ichiro
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2021, 16 (01) : 29 - 39
  • [37] Development and evaluation of a prototype detector for an intraoperative laparoscopic coincidence imaging system with PET tracers
    Madhushanka R. Liyanaarachchi
    Kenji Shimazoe
    Hiroyuki Takahashi
    Keiichi Nakagawa
    Etsuko Kobayashi
    Ichiro Sakuma
    International Journal of Computer Assisted Radiology and Surgery, 2021, 16 : 29 - 39
  • [38] ADVANCED NEW NEUROSURGICAL PROCEDURE USING INTEGRATED SYSTEM OF INTRAOPERATIVE MRI AND NEURONAVIGATION WITH MULTIMODAL NEURORADIOLOGICAL IMAGES
    Wakabayashi, Toshihiko
    Fujii, Masazumi
    Kajita, Yasukazu
    Natsume, Atsushi
    Maezawa, Satoshi
    Yoshida, Jun
    NAGOYA JOURNAL OF MEDICAL SCIENCE, 2009, 71 (3-4): : 101 - 107
  • [39] Description and validation of a computer based refrigeration system simulator
    Eames, I. W.
    Brown, T.
    Evans, J. A.
    Maidment, G. G.
    COMPUTERS AND ELECTRONICS IN AGRICULTURE, 2012, 85 : 53 - 63
  • [40] Intraoperative ultrasound imaging: Practical applicability as a real-time navigation system
    Reinacher, PC
    van Velthoven, V
    INTRAOPERATIVE IMAGING IN NEUROSURGERY: MRI, CT, ULTRASOUND, 2003, 85 : 89 - 93