New prototype neuronavigation system based on preoperative imaging and intraoperative freehand ultrasound: system description and validation

被引:49
|
作者
Mercier, Laurence [1 ]
Del Maestro, Rolando F. [2 ]
Petrecca, Kevin [2 ]
Kochanowska, Anna [1 ]
Drouin, Simon [1 ]
Yan, Charles X. B. [1 ]
Janke, Andrew L. [3 ]
Chen, Sean Jy-Shyang [1 ]
Collins, D. Louis [1 ]
机构
[1] McGill Univ, Montreal Neurol Inst, McConnell Brain Imaging Ctr, Montreal, PQ, Canada
[2] McGill Univ, Montreal Neurol Hosp & Inst, Brain Tumour Res Ctr, Montreal, PQ, Canada
[3] Australian Natl Univ, Dept Geriatr Med, Canberra, SA, Australia
基金
加拿大健康研究院;
关键词
Application accuracy; Image-guided surgery; Intraoperative imaging; Intraoperative ultrasound; Neuronavigation; Registration; BRAIN-SHIFT; 3-D ULTRASOUND; 3D ULTRASOUND; GUIDED NEUROSURGERY; TUMOR RESECTION; 3-DIMENSIONAL ULTRASOUND; REGISTRATION; CALIBRATION; MRI; ACCURACY;
D O I
10.1007/s11548-010-0535-3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose The aim of this report is to present IBIS (Interactive Brain Imaging System) NeuroNav, a new prototype neuronavigation system that has been developed in our research laboratory over the past decade that uses tracked intraoperative ultrasound to address surgical navigation issues related to brain shift. The unique feature of the system is its ability, when needed, to improve the initial patient-to-preoperative image alignment based on the intraoperative ultrasound data. Parts of IBIS Neuronav source code are now publicly available on-line. Methods Four aspects of the system are characterized in this paper: the ultrasound probe calibration, the temporal calibration, the patient-to-image registration and the MRI-ultrasound registration. In order to characterize its real clinical precision and accuracy, the system was tested in a series of adult brain tumor cases. Results Three metrics were computed to evaluate the precision and accuracy of the ultrasound calibration. 1) Reproducibility: 1.77mm and 1.65mm for the bottom corners of the ultrasound image, 2) point reconstruction precision 0.62-0.90mm: and 3) point reconstruction accuracy: 0.49-0.74mm. The temporal calibration error was estimated to be 0.82 ms. The mean fiducial registration error (FRE) of the homologous-point-based patient-to-MRI registration for our clinical data is 4.9 +/- 1.1mm. After the skin landmark-based registration, the mean misalignment between the ultrasound and MR images in the tumor region is 6.1 +/- 3.4 mm. Conclusions The components and functionality of a new prototype system are described and its precision and accuracy evaluated. It was found to have an accuracy similar to other comparable systems in the literature.
引用
收藏
页码:507 / 522
页数:16
相关论文
共 50 条
  • [21] Validation of a freehand 3D ultrasound system for determining muscle tendon unitarchitecture
    Weller, R.
    Pfau, T.
    Ferrari, M.
    Wilson, A.
    COMPARATIVE BIOCHEMISTRY AND PHYSIOLOGY A-MOLECULAR & INTEGRATIVE PHYSIOLOGY, 2005, 141 (03): : S136 - S136
  • [22] A Prototype System for High Frame Rate Ultrasound Imaging based Prosthetic Arm Control
    Singh, Ayush
    Gopalkrishnan, Pisharody Harikrishnan
    Panicker, Mahesh Raveendranatha
    2023 45TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY, EMBC, 2023,
  • [23] Investigation of 3D Reconstruction Algorithms For Wireless Freehand Ultrasound Imaging System
    Zhao, Lanxi
    Song, Sheng
    Zhang, Chunlei
    Huang, Peng
    Zhang, Yi
    Zhang, Mingbo
    Zheng, Rui
    2023 45TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY, EMBC, 2023,
  • [24] Ultrasensitive Doppler based neuronavigation system for preclinical brain imaging applications
    Cohen, Emmanuel
    Deffieux, Thomas
    Tiran, Elodie
    Demene, Charlie
    Cohen, Laurent
    Tanter, Mickael
    2016 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2016,
  • [25] A framework for human spine imaging using a freehand 3D ultrasound system
    Purnama, Ketut E.
    Wilkinson, Michael. H. F.
    Veldhuizen, Albert G.
    van Ooijen, Peter. M. A.
    Lubbers, Jaap
    Burgerhof, Johannes G. M.
    Sardjono, Tri A.
    Verkerke, Gijbertus J.
    TECHNOLOGY AND HEALTH CARE, 2010, 18 (01) : 1 - 17
  • [26] Accuracy evaluation of a 3D ultrasound-based neuronavigation system
    Lango, T
    Bang, J
    Lindseth, F
    Hernes, TAN
    CARS 2002: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2002, : 63 - 68
  • [27] Validation of a freehand 3D ultrasound system for morphological measures of the medial gastrocnemius muscle
    Barber, Lee
    Barrett, Rod
    Lichtwark, Glen
    JOURNAL OF BIOMECHANICS, 2009, 42 (09) : 1313 - 1319
  • [28] Correlation between preoperative imaging features and intraoperative blood loss of meningioma: a new scoring system for predicting intraoperative blood loss
    Lu, J.
    JOURNAL OF NEUROSURGICAL SCIENCES, 2013, 57 (02) : 153 - 161
  • [29] Post-craniotomy neuronavigation based purely on itntraoperative ultrasound imaging without preoperative neuronavigational planning Comments
    Bozinov, Oliver
    Enchev, Yavor
    NEUROSURGICAL REVIEW, 2012, 35 (02) : 268 - 268
  • [30] A system for ultrasound based intraoperative navigation in spine surgery
    Weber, PK
    Schlegel, JC
    Meiche, J
    Peter, L
    Harland, U
    2001 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2001, : 1361 - 1364