Comparison of image quality and radiation dose of different pulmonary CTA protocols on a 128-slice CT: high-pitch dual source CT, dual energy CT and conventional spiral CT

被引:61
|
作者
De Zordo, Tobias [1 ]
von Lutterotti, Klemens [1 ]
Dejaco, Christian [2 ]
Soegner, Peter F. [1 ]
Frank, Renate [1 ]
Aigner, Friedrich [1 ]
Klauser, Andrea S. [1 ]
Pechlaner, Christoph [3 ]
Schoepf, U. Joseph [4 ]
Jaschke, Werner R. [1 ]
Feuchtner, Gudrun M. [1 ]
机构
[1] Med Univ Innsbruck, Dept Radiol, A-6020 Innsbruck, Austria
[2] Med Univ Graz, Dept Rheumatol, A-8036 Graz, Austria
[3] Med Univ Innsbruck, Dept Internal Med, A-6020 Innsbruck, Austria
[4] Med Univ S Carolina, Heart & Vasc Ctr, Charleston, SC 29425 USA
关键词
Dual energy; Dual source; Computer tomography; Pulmonary embolism; Radiation; MULTIDETECTOR-ROW CT; COMPUTED-TOMOGRAPHY; LUNG PERFUSION; EMBOLISM; ANGIOGRAPHY; RECONSTRUCTION; FEASIBILITY; ARTERIES;
D O I
10.1007/s00330-011-2251-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives To compare image quality and radiation dose of high-pitch dual-source computed tomography (DSCT), dual energy CT (DECT) and conventional single-source spiral CT (SCT) for pulmonary CT angiography (CTA) on a 128-slice CT system. Methods Pulmonary CTA was performed with five protocols: high-pitch DSCT (100 kV), high-pitch DSCT (120 kV), DECT (100/140 kV), SCT (100 kV), and SCT (120 kV). For each protocol, 30 sex, age, and body-mass-index (mean 25.3 kg/m(2)) matched patients were identified. Retrospectively, two observers subjectively assessed image quality, measured CT attenuation (HU +/- SD) at seven central and peripheral levels, and calculated signal-to-noise-ratio (SNR) and contrast-to-noise-ratio (CNR). Radiation exposure parameters (CTDIvol and DLP) were compared. Results Subjective image quality was rated good to excellent in > 92% (> 138/150) with an interobserver agreement of 91.4%. The five protocols did not significantly differ in image quality, neither by subjective, nor by objective measures (SNR, CNR). By contrast, radiation exposure differed between protocols: significant lower radiation was achieved by using high-pitch DSCT at 100 kV (p < 0.01 in all). Radiation exposure of DECT was in between SCT at 100 kV and 120 kV. Conclusions SCT, high-pitch DSCT, and DECT protocols techniques result in similar subjective and objective image quality, but radiation exposure was significantly lower with high-pitch DSCT at 100 kV. Key Points New CT protocols show promising results in pulmonary embolism assessment. High-pitch dual-source CT (DSCT) at 100 kV provides radiation dose savings for pulmonary CTA. High-pitch DSCT at 100 kV maintains diagnostic image quality for pulmonary CTA. Dual energy CT uses more radiation but also provides lung perfusion evaluation. Whether the additional perfusion data is worth the extra radiation remains undetermined.
引用
收藏
页码:279 / 286
页数:8
相关论文
共 50 条
  • [31] DIAGNOSTIC ACCURACY OF 128-SLICE DUAL-SOURCE CT USING HIGH-PITCH SPIRAL MODE IN ASSESSMENT OF CORONARY ARTERY STENT IMAGING COMPARISON WITH INVASIVE CORONARY ANGIOGRAPHY
    Yang Xia
    Chen Yundai
    HEART, 2012, 98 : E290 - E290
  • [32] Radiation dose and image quality of high-pitch emergency abdominal CT in obese patients using third-generation dual-source CT (DSCT)
    Forbrig, Robert
    Ingrisch, Michael
    Stahl, Robert
    Winter, Katharina Stella
    Reiser, Maximilian
    Trumm, Christoph G.
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [33] Efficacy of high-pitch CT protocols for radiation dose reduction
    Guberina, N.
    Lechel, U.
    Forsting, M.
    Ringelstein, A.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2016, 36 (04) : N57 - N66
  • [34] Radiation dose and image quality of high-pitch emergency abdominal CT in obese patients using third-generation dual-source CT (DSCT)
    Robert Forbrig
    Michael Ingrisch
    Robert Stahl
    Katharina Stella Winter
    Maximilian Reiser
    Christoph G. Trumm
    Scientific Reports, 9
  • [35] Dose and image quality at CT pulmonary angiography-comparison of first and second generation dual-energy CT and 64-slice CT
    Bauer, Ralf W.
    Kramer, Sebastian
    Renker, Matthias
    Schell, Boris
    Larson, Maya Christina
    Beeres, Martin
    Lehnert, Thomas
    Jacobi, Volkmar
    Vogl, Thomas J.
    Kerl, Josef Matthias
    EUROPEAN RADIOLOGY, 2011, 21 (10) : 2139 - 2147
  • [36] Improved Pulmonary Artery Evaluation Using High-Pitch Photon-Counting CT Compared to High-Pitch Conventional or Routine-Pitch Conventional Dual-Energy CT
    Yalon, Mariana
    Hoodeshenas, Safa
    Chan, Alex
    Horst, Kelly K.
    Crum, Isaac
    Thorne, Jamison E.
    Lee, Yong S.
    Yu, Lifeng
    Mccollough, Cynthia H.
    Fletcher, Joel G.
    Rajiah, Prabhakar Shantha
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2024, 48 (06) : 897 - 905
  • [37] High-pitch dual-source CT angiography of supra-aortic arteries: assessment of image quality and radiation dose
    Korn, A.
    Fenchel, M.
    Bender, B.
    Danz, S.
    Thomas, C.
    Ketelsen, D.
    Claussen, C. D.
    Moonis, G.
    Krauss, B.
    Heuschmid, M.
    Ernemann, U.
    Brodoefel, H.
    NEURORADIOLOGY, 2013, 55 (04) : 423 - 430
  • [38] High-pitch dual-source CT angiography of supra-aortic arteries: assessment of image quality and radiation dose
    A. Korn
    M. Fenchel
    B. Bender
    S. Danz
    C. Thomas
    D. Ketelsen
    C. D. Claussen
    G. Moonis
    B. Krauss
    M. Heuschmid
    U. Ernemann
    H. Brodoefel
    Neuroradiology, 2013, 55 : 423 - 430
  • [39] Image Quality and Radiation Dose for Prospectively Triggered Coronary CT Angiography: 128-Slice Single-Source CT versus First-Generation 64-Slice Dual-Source CT (vol 6, 34795, 2016)
    Gu, Jin
    Shi, He-shui
    Han, Ping
    Yu, Jie
    Ma, Gui-na
    Wu, Sheng
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [40] Quantitative hepatic CT perfusion measurement: Comparison of Couinaud's hepatic segments with dual-source 128-slice CT
    Wang, Xuan
    Xue, Hua-dan
    Jin, Zheng-yu
    Su, Bai-yan
    Li, Zhuo
    Sun, Hao
    Chen, Yu
    Liu, Wei
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (02) : 220 - 226