Comparison of image quality and radiation dose of different pulmonary CTA protocols on a 128-slice CT: high-pitch dual source CT, dual energy CT and conventional spiral CT

被引:61
|
作者
De Zordo, Tobias [1 ]
von Lutterotti, Klemens [1 ]
Dejaco, Christian [2 ]
Soegner, Peter F. [1 ]
Frank, Renate [1 ]
Aigner, Friedrich [1 ]
Klauser, Andrea S. [1 ]
Pechlaner, Christoph [3 ]
Schoepf, U. Joseph [4 ]
Jaschke, Werner R. [1 ]
Feuchtner, Gudrun M. [1 ]
机构
[1] Med Univ Innsbruck, Dept Radiol, A-6020 Innsbruck, Austria
[2] Med Univ Graz, Dept Rheumatol, A-8036 Graz, Austria
[3] Med Univ Innsbruck, Dept Internal Med, A-6020 Innsbruck, Austria
[4] Med Univ S Carolina, Heart & Vasc Ctr, Charleston, SC 29425 USA
关键词
Dual energy; Dual source; Computer tomography; Pulmonary embolism; Radiation; MULTIDETECTOR-ROW CT; COMPUTED-TOMOGRAPHY; LUNG PERFUSION; EMBOLISM; ANGIOGRAPHY; RECONSTRUCTION; FEASIBILITY; ARTERIES;
D O I
10.1007/s00330-011-2251-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives To compare image quality and radiation dose of high-pitch dual-source computed tomography (DSCT), dual energy CT (DECT) and conventional single-source spiral CT (SCT) for pulmonary CT angiography (CTA) on a 128-slice CT system. Methods Pulmonary CTA was performed with five protocols: high-pitch DSCT (100 kV), high-pitch DSCT (120 kV), DECT (100/140 kV), SCT (100 kV), and SCT (120 kV). For each protocol, 30 sex, age, and body-mass-index (mean 25.3 kg/m(2)) matched patients were identified. Retrospectively, two observers subjectively assessed image quality, measured CT attenuation (HU +/- SD) at seven central and peripheral levels, and calculated signal-to-noise-ratio (SNR) and contrast-to-noise-ratio (CNR). Radiation exposure parameters (CTDIvol and DLP) were compared. Results Subjective image quality was rated good to excellent in > 92% (> 138/150) with an interobserver agreement of 91.4%. The five protocols did not significantly differ in image quality, neither by subjective, nor by objective measures (SNR, CNR). By contrast, radiation exposure differed between protocols: significant lower radiation was achieved by using high-pitch DSCT at 100 kV (p < 0.01 in all). Radiation exposure of DECT was in between SCT at 100 kV and 120 kV. Conclusions SCT, high-pitch DSCT, and DECT protocols techniques result in similar subjective and objective image quality, but radiation exposure was significantly lower with high-pitch DSCT at 100 kV. Key Points New CT protocols show promising results in pulmonary embolism assessment. High-pitch dual-source CT (DSCT) at 100 kV provides radiation dose savings for pulmonary CTA. High-pitch DSCT at 100 kV maintains diagnostic image quality for pulmonary CTA. Dual energy CT uses more radiation but also provides lung perfusion evaluation. Whether the additional perfusion data is worth the extra radiation remains undetermined.
引用
收藏
页码:279 / 286
页数:8
相关论文
共 50 条
  • [21] Diagnostic accuracy of 128-slice dual-source CT coronary angiography: a randomized comparison of different acquisition protocols
    Lisan A. Neefjes
    Alexia Rossi
    Tessa S. S. Genders
    Koen Nieman
    Stella L. Papadopoulou
    Anoeshka S. Dharampal
    Carl J. Schultz
    Annick C. Weustink
    Marcel L. Dijkshoorn
    Gert-Jan R. ten Kate
    Admir Dedic
    Marcel van Straten
    Filippo Cademartiri
    M. G. Myriam Hunink
    Gabriël P. Krestin
    Pim J. de Feyter
    Nico R. Mollet
    European Radiology, 2013, 23 : 614 - 622
  • [22] Coronary artery stent imaging with 128-slice dual-source CT using high-pitch spiral acquisition in a cardiac phantom: comparison with the sequential and low-pitch spiral mode
    Florian Wolf
    Sebastian Leschka
    Christian Loewe
    Peter Homolka
    Christina Plank
    Ruediger Schernthaner
    Dominik Bercaczy
    Robert Goetti
    Johannes Lammer
    Guy Friedrich
    Borut Marincek
    Hatem Alkadhi
    Gudrun Feuchtner
    European Radiology, 2010, 20 : 2084 - 2091
  • [23] Image quality and radiation exposure of low-dose protocols for coronary CT angiography: comparison of prospectively triggered axial scanning and high-pitch spiral CT
    Seltmann, M.
    Achenbach, S.
    Goroll, T.
    Marwan, M.
    Pflederer, T.
    Ropers, D.
    Lell, M.
    Anders, K.
    Uder, M.
    Daniel, W. G.
    EUROPEAN HEART JOURNAL, 2010, 31 : 293 - 293
  • [24] Author Correction: Image Quality and Radiation Dose for Prospectively Triggered Coronary CT Angiography: 128-Slice Single-Source CT versus First-Generation 64-Slice Dual-Source CT
    Jin Gu
    He-shui Shi
    Ping Han
    Jie Yu
    Gui-na Ma
    Sheng Wu
    Scientific Reports, 10
  • [25] Feasibility and Radiation Dose of High-Pitch Acquisition Protocols in Patients Undergoing Dual-Source Cardiac CT
    Sommer, Wieland H.
    Albrecht, Edda
    Bamberg, Fabian
    Schenzle, Jan C.
    Johnson, Thorsten R.
    Neumaier, Klement
    Reiser, Maximilian F.
    Nikolaou, Konstatin
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (06) : 1306 - 1312
  • [26] The ascending aortic image quality and the whole aortic radiation dose of high-pitch dual-source CT angiography
    Ying Liu
    Jian Xu
    Jian Li
    Jing Ren
    Hongtao Liu
    Junqing Xu
    Mengqi Wei
    Yuewen Hao
    Minwen Zheng
    Journal of Cardiothoracic Surgery, 8
  • [27] Comparison of 128-Slice Dual Source CT Coronary Angiography with Invasive Coronary Angiography
    Madhok, Rajneesh
    Aggarwal, Abhinav
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2014, 8 (06) : RC8 - RC11
  • [28] The ascending aortic image quality and the whole aortic radiation dose of high-pitch dual-source CT angiography
    Liu, Ying
    Xu, Jian
    Li, Jian
    Ren, Jing
    Liu, Hongtao
    Xu, Junqing
    Wei, Mengqi
    Hao, Yuewen
    Zheng, Minwen
    JOURNAL OF CARDIOTHORACIC SURGERY, 2013, 8
  • [29] Dose and image quality at CT pulmonary angiography—comparison of first and second generation dual-energy CT and 64-slice CT
    Ralf W. Bauer
    Sebastian Kramer
    Matthias Renker
    Boris Schell
    Maya Christina Larson
    Martin Beeres
    Thomas Lehnert
    Volkmar Jacobi
    Thomas J. Vogl
    Josef Matthias Kerl
    European Radiology, 2011, 21 : 2139 - 2147
  • [30] Radiation Dose and Image Quality at High-Pitch CT Angiography of the Aorta: Intraindividual and Interindividual Comparisons With Conventional CT Angiography
    Apfaltrer, Paul
    Hanna, E. Lexworth
    Schoepf, U. Joseph
    Spears, J. Reid
    Schoenberg, Stefan O.
    Fink, Christian
    Vliegenthart, Rozemarijn
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (06) : 1402 - 1409