Low dose rate γ-ray detection using a MAPS camera under a neutron radiation environment

被引:4
|
作者
Xu, Shoulong [1 ]
Zhao, Fang [1 ]
Zou, Yang [2 ]
Sun, Meilan [1 ]
Zou, Shuliang [1 ]
Han, Yongchao [3 ]
Huang, Youjun [4 ]
Yu, Xiuwu [1 ]
Gong, Dawei [5 ]
Qu, Yantao [3 ]
Liu, Houdong [1 ]
Yang, Huaiqing [1 ]
机构
[1] Univ South China, Hengyang 421001, Hunan, Peoples R China
[2] China Natl Nucl Corp, Beijing 100822, Peoples R China
[3] China Inst Atom Energy, Beijing 102413, Peoples R China
[4] Nucl Power Inst China, Chengdu 610213, Sichuan, Peoples R China
[5] Univ Elect Sci & Technol China, Chengdu 611731, Peoples R China
来源
OPTICS EXPRESS | 2021年 / 29卷 / 22期
基金
中国国家自然科学基金;
关键词
SENSOR;
D O I
10.1364/OE.437580
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We present gamma-ray radiation detection in a neutron radiation environment using a monolithic active pixel sensor (MAPS) camera without conversion or shielding layers. The measured output signal is the sum of the pedestal value, noise, and real radiation response signal. The sensor response shows that the MAPS camera is sensitive to neutrons and can capture a single photon. The number of pixels with a signal exceeding 100 exhibits a strong dependence on the dose rate and is the best indicator of this value. Therefore, a MAPS camera can be efficiently used as a radiation detection sensor in a robotic system, further limiting human errors in performing radiation detection in complex nuclear radiation environments. (C) 2021 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
引用
收藏
页码:34913 / 34925
页数:13
相关论文
共 50 条
  • [11] Maintaining low radiation damage of lead tungstate scintillation crystals operating in high dose rate radiation environment
    Borisevitch, Andrei E.
    Dormenev, Valeri I.
    Fedorov, Andrei A.
    Korjik, Mikhail V.
    Kuske, Till
    Mechinsky, Vitali
    Missevitch, Oleg V.
    Novotny, Rainer W.
    Rusack, Rodger
    Singovski, Alexander V.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 1010 - 1013
  • [12] Low dose rate accelerated radiation therapy
    Pierquin, B.
    Tubiana, M.
    Calitchi, Elie
    Pan, Camille
    Lagrange, Jean-Leon
    Mazeron, Jean-Jacques
    Otmezguine, Yves
    wilson, Frank
    CANCER RADIOTHERAPIE, 2007, 11 (08): : 441 - 442
  • [13] GAMMA-RAY INDUCED CONDUCTIVITY IN POLYETHYLENE AND TEFLON UNDER RADIATION AT HIGH DOSE RATE
    YAHAGI, K
    DANNO, A
    JOURNAL OF APPLIED PHYSICS, 1963, 34 (04) : 804 - &
  • [14] Radiation-associated cancer risk at low dose and low dose rate
    Kakinuma, Shizuko
    Tsuruoka, Chizuru
    Shimada, Yoshiya
    CANCER SCIENCE, 2018, 109 : 164 - 164
  • [15] Apoptosis induced by low-dose and low-dose-rate radiation
    Mirzaie-Joniani, H
    Eriksson, D
    Sheikholvaezin, A
    Johansson, A
    Löfroth, PO
    Johansson, L
    Stigbrand, T
    CANCER, 2002, 94 (04) : 1210 - 1214
  • [16] Combined Environment Simulator for Low-Dose-Rate Radiation and Partial Gravity of Moon and Mars
    Takahashi, Akihisa
    Yamanouchi, Sakuya
    Takeuchi, Kazuomi
    Takahashi, Shogo
    Tashiro, Mutsumi
    Hidema, Jun
    Higashitani, Atsushi
    Adachi, Takuya
    Zhang, Shenke
    Guirguis, Fady Nagy Lotfy
    Yoshida, Yukari
    Nagamatsu, Aiko
    Hada, Megumi
    Takeuchi, Kunihito
    Takahashi, Tohru
    Sekitomi, Yuji
    LIFE-BASEL, 2020, 10 (11): : 1 - 13
  • [17] ESTABLISHMENT OF A LOW DOSE RATE GAMMA RAY CALIBRATION FIELD FOR ENVIRONMENTAL RADIATION MONITORING DEVICES
    Kowatari, Munehiko
    Yoshitomi, Hiroshi
    Nishino, Sho
    Tanimura, Yoshihiko
    Ohishi, Tetsuya
    Kessler, Patrick
    Neumaier, Stefan
    Roettger, Annette
    RADIATION PROTECTION DOSIMETRY, 2019, 187 (01) : 61 - 68
  • [18] Establishment of low-dose rate X-ray radiation quality and calibration of the instruments
    Li M.
    Zhao R.
    Qu B.
    Lu P.
    Song F.
    Li Y.
    Fu L.
    Wu J.
    He Jishu/Nuclear Techniques, 2022, 45 (06):
  • [19] Low cost CCD camera protection against neutron radiation damage
    Kok, J.G.M.
    Journal of Medical Engineering and Technology, 2005, 29 (01): : 27 - 32
  • [20] Studies of mutagenesis caused by low dose rate tritium radiation using a novel hyper-sensitive detection system
    Tauchi, H
    Ichimasa, M
    Ichimasa, Y
    Shiraishi, T
    Morishima, K
    Matsuura, S
    Komatsu, K
    FUSION SCIENCE AND TECHNOLOGY, 2002, 41 (03) : 413 - 416