Studies of mutagenesis caused by low dose rate tritium radiation using a novel hyper-sensitive detection system

被引:10
|
作者
Tauchi, H
Ichimasa, M
Ichimasa, Y
Shiraishi, T
Morishima, K
Matsuura, S
Komatsu, K
机构
[1] Ibaraki Univ, Dept Environm Sci, Mito, Ibaraki 3108512, Japan
[2] Hiroshima Univ, Dept Radiat Biol, Minami Ku, Hiroshima 7348553, Japan
关键词
D O I
10.13182/FST02-A22622
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
A novel hyper-sensitive detection system was developed to detect Hprt-deficient mutations using Hprt deficient hamster fibroblast cells which carry a normal human X-chromosome. The system has been found to be 100-fold more sensitive for detecting mutations than the conventional system which uses an internal Hprt gene. The mutation frequency induced by 1 Gy of tritium radiation at different dose rates (0.9, 0.4, 0.04, and 0.018 Gy/h) was measured. No significant differences in mutation frequencies were observed within the range of dose rates used, suggesting that if a reverse dose-rate effect exists, it may not be observable with tritium radiation at dose rates over 0.018 Gy/h. Interestingly, molecular analysis of the Hprt locus in Hprt-deficient mutants induced by tritium showed that deletion sizes observed in the hamster cell's human X-chromosome under these conditions are much smaller in cells exposed at 0.04 (and 0.018 Gy/h) than in cells exposed at 0.9 Gy/h. This phenomenon seems to be specific for tritium radiation because it was not apparent after exposure to gamma-rays. The novel hyper-sensitive detection system used here is useful for analysis of the mutagenic effects of low doses of tritium radiation delivered at low dose rates.
引用
收藏
页码:413 / 416
页数:4
相关论文
共 11 条
  • [1] Characterization of a novel large area microdosimeter system for low dose rate radiation environments
    Pan, Vladimir A.
    Pagani, Federico
    James, Benjamin
    Bolst, David
    Peracchi, Stefania
    Vohradsky, James
    Pogossov, Alex
    Guatelli, Susanna
    Petasecca, Marco
    Lerch, Michael L. F.
    Prokopovich, Dale A.
    Boardman, David
    Perevertaylo, Vladimir L.
    Chambers, Scott D.
    Williams, Alastair G.
    Werczynski, Sylvester
    Inaniwa, Taku
    Matsufuji, Naruhiro
    Jackson, Michael
    Tran, Linh T.
    Rosenfeld, Anatoly B.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 1002
  • [2] Low dose rate γ-ray detection using a MAPS camera under a neutron radiation environment
    Xu, Shoulong
    Zhao, Fang
    Zou, Yang
    Sun, Meilan
    Zou, Shuliang
    Han, Yongchao
    Huang, Youjun
    Yu, Xiuwu
    Gong, Dawei
    Qu, Yantao
    Liu, Houdong
    Yang, Huaiqing
    OPTICS EXPRESS, 2021, 29 (22): : 34913 - 34925
  • [3] High-dose rate detection system for gamma and X radiation using scattered gamma rays
    Yi, Yicheng
    Guan, Xingyin
    Song, Zhaohui
    Tan, Xinjian
    Gao, Shuai
    Han, Hetong
    Lu, Yi
    Li, Gang
    Zhang, Kan
    Liu, Junhong
    RADIATION MEASUREMENTS, 2023, 162
  • [4] TUMOR CURE STUDIES ON THE RAT SARCOMA BA-1112 USING CONTINUOUS LOW-DOSE-RATE RADIATION
    PESCHEL, RE
    MARTIN, DF
    FISCHER, JJ
    RADIOLOGY, 1984, 152 (03) : 801 - 803
  • [6] Biofluid Metabolomics of Mice Exposed to External Low-Dose Rate Radiation in a Novel Irradiation System, the Variable Dose-Rate External 137Cs Irradiator
    Pannkuk, Evan L.
    Laiakis, Evagelia C.
    Girgis, Michael
    Garty, Guy Y.
    Morton, Shad R.
    Pujol-Canadell, Monica
    Ghandhi, Shanaz A.
    Amundson, Sally A.
    Brenner, David J.
    Fornace, Albert J., Jr.
    JOURNAL OF PROTEOME RESEARCH, 2021, 20 (11) : 5145 - 5155
  • [7] POSTOPERATIVE HYPER-COAGULABILITY, DETECTION AND MEASUREMENT USING A MODIFIED RECALCIFICATION TIME SYSTEM, EFFECTS OF LOW-DOSE HEPARIN AND TYPES OF SURGERY
    LUNDQUIST, PB
    SWEDENBORG, J
    THROMBOSIS AND HAEMOSTASIS, 1981, 46 (01) : 16 - 16
  • [8] Ultrasensitive detection of low-dose gamma radiation using polymeric thin films on microelectromechanical system-based sensors
    Shamma, Khaled
    Albrithen, Hamad
    AlOtaibi, Bander S.
    Alodhayb, Abdullah
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2022, 59 (12) : 1567 - 1575
  • [9] Identification of missed pulmonary nodules on low dose CT lung cancer screening studies using an automatic detection system
    Novak, CL
    Li, F
    Qian, JZ
    Wei, GQ
    Naidich, DP
    MEDICAL IMAGING 2003: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2003, 5034 : 439 - 447
  • [10] Novel Technique Using Full-Dose Low-Dose-Rate Brachytherapy With Field-Matched Pelvic Intensity Modulated Radiation Therapy for High-Risk Prostate Cancer Improves Rectal Sparing
    Gallaher, I. S.
    Johnson, J.
    Wang, X.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E679 - E679