Low cost CCD camera protection against neutron radiation damage

被引:0
|
作者
Kok, J.G.M. [1 ]
机构
[1] Department of Radiotherapy, University Medical Centre, Heidelberglaan 100, 3584 CX Utrecht, Netherlands
来源
关键词
Cameras - Linear accelerators - Neutrons - Patient treatment - Radiation damage - Radiotherapy - Tumors;
D O I
10.1080/03091900410001701914
中图分类号
学科分类号
摘要
At a radiotherapy department cancer patients are treated with high energy electron and photon beams. These beams are produced by a linear accelerator. A closed circuit television system is used to monitor patients during treatment. Although CCD cameras are rather resistant to stray radiation, they are damaged by the low flux of neutrons which are produced by the linac as a side effect. PVC can be used to reduce damage to CCD cameras induced by neutron radiation. A box with 6 cm thick walls will extend the life of the camera at least by a factor of two. A PVC neutron shield is inexpensive. PVC is easy to obtain and the box is simple to construct. A similar box made out of PE will not reduce neutron damage to a CCD camera. Although PE is a good medium to moderate faster neutrons, thereby reducing some of the bulk defects, it will not capture thermal neutrons which induce surface damage.
引用
收藏
页码:27 / 32
相关论文
共 50 条
  • [1] Development of low cost CCD camera for microsatellites
    Zhou J.
    Chen X.
    Chen Y.
    Zhou W.
    Shen W.
    Zhongguo Jiguang/Chinese Journal of Lasers, 2010, 37 (SUPPL. 1): : 120 - 125
  • [2] Investigation of radiation damage effects in neutron irradiated CCD
    Brau, JE
    Igonkina, O
    Potter, CT
    Sinev, NB
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 549 (1-3): : 117 - 121
  • [3] PROTECTION AGAINST NEUTRON BOMB RADIATION
    SAHIN, S
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1979, 33 (NOV): : 677 - 678
  • [4] CHEMICAL PROTECTION AGAINST RADIATION DAMAGE
    MAISIN, JR
    DOHERTY, DG
    FEDERATION PROCEEDINGS, 1960, 19 (01) : 356 - 356
  • [5] CHEMICAL PROTECTION AGAINST RADIATION DAMAGE
    CAMPAIGN.E
    AMERICAN BIOLOGY TEACHER, 1969, 31 (09): : 600 - &
  • [6] Development of a Radiation Monitoring Device Using a Low-Cost CCD Camera Following Radionuclide Therapy
    Taneja, S.
    Fru, L. Che
    Desai, V.
    Lentz, J.
    Lin, C.
    Scarpelli, M.
    Simiele, E.
    Trestrail, A.
    Bednarz, B.
    MEDICAL PHYSICS, 2015, 42 (06) : 3537 - 3537
  • [7] Electron and neutron radiation damage effects on a two-phase CCD
    Stefanov, KD
    Tsukamoto, T
    Miyamoto, A
    Sugimoto, Y
    Tamura, N
    Abe, K
    Nagamine, T
    Aso, T
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (03) : 1280 - 1291
  • [8] NEUTRON RADIATION DAMAGE IN CCD CAMERAS AT JOINT EUROPEAN TORUS (JET)
    Milocco, Alberto
    Conroy, Sean
    Popovichev, Sergey
    Sergienko, Gennady
    Huber, Alexander
    RADIATION PROTECTION DOSIMETRY, 2018, 180 (1-4) : 109 - 114
  • [9] Electron and neutron radiation damage effects on a two-phase CCD
    Stefanov, K.D.
    Tsukamoto, T.
    Miyamoto, A.
    Sugimoto, Y.
    Tamura, N.
    Abe, K.
    Nagamine, T.
    Aso, T.
    IEEE Transactions on Nuclear Science, 2000, 47 (3 IV) : 1280 - 1291
  • [10] LIBS spectra of polychromes with a low cost CCD camera based detector
    Martin, Margarita
    Castillejo, Marta
    Torres, Ricardo
    Silva, Diego
    Guerra-Librero, Fernando