OBJECTIVE The purpose of the study was to evaluate the treatment field deviations in lung cancer patients treated with thoracic radiotherapy (RT) performed using different immobilization devices into three different set-up positions and the influencing factors. METHODS Thirty lung cancer patients having palliative thoracic RT indication were randomized into three different set-up positions using different immobilization devices (Group I: arm along the body, Group II: lung board, and Group III: arm supported board). The treatment field center deviation was measured on sternal (X and Y axis) and axillary (z and theta axis) cross. In addition, parameters such as age, pain, pulmonary function test, set-up time, the temperature difference between the treatment room and the outside environment, and patient education level that may cause set-up were evaluated. RESULTS Mean intra-fraction field center deviations of 5.66 +/- 4.15 mm were observed in the right (z) axis (p=0.049) and 5.53 +/- 4.81 mm in the left (z) axis (p=0.015) in Group II which were statistically significantly larger than the deviations in other groups. A statistically significant correlation was found between the indoor and outdoor temperature difference and set-up time. CONCLUSION Both set-up positions of Groups I and III, gave better results than the position of Group II. According to our results, if a lung board will be used, adding the arm supporting accessory will be necessary. Random errors can be minimized and the set-up quality improved by using appropriate immobilization devices, minimizing the total set-up time and balancing the in and outdoor temperature by air conditioning system.
引用
收藏
页码:394 / 402
页数:9
相关论文
共 50 条
  • [1] Accuracy of set-up of thoracic radiotherapy: prospective analysis of 24 patients treated with radiotherapy for lung cancer
    Essapen, S
    Knowles, C
    Norman, A
    Tait, D
    BRITISH JOURNAL OF RADIOLOGY, 2002, 75 (890): : 162 - 169
  • [2] Evaluation of set-up deviations during the irradiation of patients suffering from breast cancer treated with two different techniques
    Kukolowicz, PF
    Debrowski, A
    Gut, P
    Chmielewski, L
    Wieczorek, A
    Kedzierawski, P
    RADIOTHERAPY AND ONCOLOGY, 2005, 75 (01) : 22 - 27
  • [3] Study On Set-Up Accuracy of Three Different Immobilization Methods in Radiotherapy for Thoracic Cancer
    Chen, J.
    Chen, L.
    Yin, Y.
    MEDICAL PHYSICS, 2015, 42 (06) : 3501 - 3501
  • [4] Evaluation of the trend of set-up errors during the treatment period using set-up margin in prostate radiotherapy
    Sasaki, Hinako
    Morishita, Takumi
    Irie, Naho
    Kojima, Rena
    Kiriyama, Tetsukazu
    Nakamoto, Akira
    Nishioka, Kunio
    Takahashi, Shotaro
    Tanabe, Yoshinori
    MEDICAL DOSIMETRY, 2024, 49 (04) : 291 - 297
  • [5] The effects of set-up errors on dose distribution in radiotherapy treatment for lung cancer
    Cao, X.
    Liu, M.
    Zhai, F.
    Li, N.
    Bao, C.
    Liu, Y.
    Chen, G.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2021, 19 (03): : 515 - 520
  • [6] Construction of Prediction Model of Radiotherapy Set-Up Errors in Patients with Lung Cancer
    Yang, Fan
    Li, Xinxia
    BIOMED RESEARCH INTERNATIONAL, 2022, 2022
  • [7] Construction of Prediction Model of Radiotherapy Set-Up Errors in Patients with Lung Cancer
    Yang, Fan
    Li, Xinxia
    BIOMED RESEARCH INTERNATIONAL, 2022, 2022
  • [8] Conformal radiotherapy planning for lung cancer: Analysis of set-up uncertainties
    Giraud, Philippe
    De Rycke, Yann
    Rosenwald, Jean-Claude
    Cosset, Jean-Marc
    CANCER INVESTIGATION, 2007, 25 (01) : 38 - 46
  • [9] SET-UP DEVIATIONS IN PRONE VERSUS SUPINE POSITION FOR RECTAL CANCER PATIENTS
    Romao, D.
    Lopes, S.
    Gallego, E.
    Ramalho, M.
    Dionisio, A.
    Alves, J.
    Vieira, F.
    Ribeiro, S.
    Inacio, R.
    Vieira, G. P.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S182 - S182
  • [10] Optimisation of treatment set-up during high dose radiotherapy of the prostate
    Syndikus, I.
    Heaton, A.
    Mayles, W.
    Sage, J.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S195 - S196