Evaluation of the Treatment Field Deviations in Different Set-up Positions During Thoracic Radiotherapy in Lung Cancer Patients

被引:0
|
作者
Guzeloz, Zeliha [1 ]
Ellidokuz, Hulya [2 ]
Yildirim, Ayse [3 ]
Yigitbasi, Levent [3 ]
Cetingoz, Riza [3 ]
机构
[1] Univ Hlth Sci, Tepecik Training & Res Hosp, Dept Radiat Oncol, Izmir, Turkey
[2] Dokuz Eylul Univ, Dept Prevent Med, Fac Med, Izmir, Turkey
[3] Dokuz Eylul Univ, Dept Radiat Oncol, Fac Med, Izmir, Turkey
来源
关键词
Immobilization device; inter-fractional motion; intra-fraction motion; lung cancer; set-up error; thoracic radiotherapy; RADIATION-THERAPY; IMMOBILIZATION; REPRODUCIBILITY; RELAPSE;
D O I
10.5505/tjo.2022.3584
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
OBJECTIVE The purpose of the study was to evaluate the treatment field deviations in lung cancer patients treated with thoracic radiotherapy (RT) performed using different immobilization devices into three different set-up positions and the influencing factors. METHODS Thirty lung cancer patients having palliative thoracic RT indication were randomized into three different set-up positions using different immobilization devices (Group I: arm along the body, Group II: lung board, and Group III: arm supported board). The treatment field center deviation was measured on sternal (X and Y axis) and axillary (z and theta axis) cross. In addition, parameters such as age, pain, pulmonary function test, set-up time, the temperature difference between the treatment room and the outside environment, and patient education level that may cause set-up were evaluated. RESULTS Mean intra-fraction field center deviations of 5.66 +/- 4.15 mm were observed in the right (z) axis (p=0.049) and 5.53 +/- 4.81 mm in the left (z) axis (p=0.015) in Group II which were statistically significantly larger than the deviations in other groups. A statistically significant correlation was found between the indoor and outdoor temperature difference and set-up time. CONCLUSION Both set-up positions of Groups I and III, gave better results than the position of Group II. According to our results, if a lung board will be used, adding the arm supporting accessory will be necessary. Random errors can be minimized and the set-up quality improved by using appropriate immobilization devices, minimizing the total set-up time and balancing the in and outdoor temperature by air conditioning system.
引用
收藏
页码:394 / 402
页数:9
相关论文
共 50 条
  • [32] THE EFFECT OF SET-UP ERROR ON DELIVERED DOSE IN CURATIVE RADIOTHERAPY FOR NON-SMALL CELL LUNG CANCER
    Xing, Aitang
    Holloway, Lois
    Kumar, Shivani
    Ochoa, Cesar
    Vinod, Shalini K.
    JOURNAL OF THORACIC ONCOLOGY, 2011, 6 (06) : S803 - S804
  • [33] Impact of inter- and intrafraction deviations and residual set-up errors on PTV margins Different alignment techniques in 3D conformal prostate cancer radiotherapy
    Langsenlehner, T.
    Doeller, C.
    Winkler, P.
    Galle, G.
    Kapp, K. S.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2013, 189 (04) : 321 - +
  • [34] Can teaching patients with pelvic tumours about correct positioning improve treatment set-up in radiotherapy?
    Hansen, H.
    Boejen, A.
    Ellegaard, M. Bjorklund
    Vestergaard, A.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S121 - S121
  • [35] Intraoral stent reduces set-up errors in image guided radiotherapy for head and neck cancer patients
    Tarutani, K.
    Doi, H.
    Tanooka, M.
    Ishida, T.
    Kosaka, K.
    Ichimiya, K.
    Moridera, K.
    Kitajima, K.
    Yasuhiro, T.
    Fujiwara, M.
    Kishimoto, H.
    Kamikonya, N.
    EUROPEAN JOURNAL OF CANCER, 2017, 72 : S108 - S108
  • [36] Intra thoracic anatomical changes in lung cancer patients during the course of radiotherapy
    Kwint, Margriet
    Conijn, Sanne
    Schaake, Eva
    Knegjens, Joost
    Rossi, Maddalena
    Remeijer, Peter
    Sonke, Jan-Jakob
    Belderbos, Jose
    RADIOTHERAPY AND ONCOLOGY, 2014, 113 (03) : 392 - 397
  • [37] EVALUATION OF THE EFFECT OF TUMOUR BED MARKER MOVEMENT UPON PATIENT SET-UP ACCURACY DURING BREAST RADIOTHERAPY
    Harris, E.
    Donovan, E.
    Coles, C.
    Eagle, S.
    Kirby, A.
    Evans, P.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S439 - S439
  • [38] Evaluation of the validity of a convolution method for incorporating tumour movement and set-up variations into the radiotherapy treatment planning system
    McCarter, SD
    Beckham, WA
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (04): : 923 - 931
  • [39] Evaluation of set-up verification with the analysis of systematic and random errors in radiotherapy - a study of the Great Poland Cancer Centre
    Szczurek, Lukasz
    Skrobala, Agnieszka
    Piotrowski, Tomasz
    Jodda, Agata
    NUKLEONIKA, 2008, 53 (04) : 167 - 171
  • [40] Optimal gantry angles and field sizes in kilovoltage cone-beam tomosynthesis for set-up of women with breast cancer undergoing radiotherapy treatment
    Lyatskaya, Yulia
    Buehler, Andreas
    Ng, Sook-Kien
    Wong, Julia
    Bellon, Jennifer R.
    Zygmanski, Piotr
    RADIOTHERAPY AND ONCOLOGY, 2009, 93 (03) : 633 - 638