Evaluation of the Treatment Field Deviations in Different Set-up Positions During Thoracic Radiotherapy in Lung Cancer Patients

被引:0
|
作者
Guzeloz, Zeliha [1 ]
Ellidokuz, Hulya [2 ]
Yildirim, Ayse [3 ]
Yigitbasi, Levent [3 ]
Cetingoz, Riza [3 ]
机构
[1] Univ Hlth Sci, Tepecik Training & Res Hosp, Dept Radiat Oncol, Izmir, Turkey
[2] Dokuz Eylul Univ, Dept Prevent Med, Fac Med, Izmir, Turkey
[3] Dokuz Eylul Univ, Dept Radiat Oncol, Fac Med, Izmir, Turkey
来源
关键词
Immobilization device; inter-fractional motion; intra-fraction motion; lung cancer; set-up error; thoracic radiotherapy; RADIATION-THERAPY; IMMOBILIZATION; REPRODUCIBILITY; RELAPSE;
D O I
10.5505/tjo.2022.3584
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
OBJECTIVE The purpose of the study was to evaluate the treatment field deviations in lung cancer patients treated with thoracic radiotherapy (RT) performed using different immobilization devices into three different set-up positions and the influencing factors. METHODS Thirty lung cancer patients having palliative thoracic RT indication were randomized into three different set-up positions using different immobilization devices (Group I: arm along the body, Group II: lung board, and Group III: arm supported board). The treatment field center deviation was measured on sternal (X and Y axis) and axillary (z and theta axis) cross. In addition, parameters such as age, pain, pulmonary function test, set-up time, the temperature difference between the treatment room and the outside environment, and patient education level that may cause set-up were evaluated. RESULTS Mean intra-fraction field center deviations of 5.66 +/- 4.15 mm were observed in the right (z) axis (p=0.049) and 5.53 +/- 4.81 mm in the left (z) axis (p=0.015) in Group II which were statistically significantly larger than the deviations in other groups. A statistically significant correlation was found between the indoor and outdoor temperature difference and set-up time. CONCLUSION Both set-up positions of Groups I and III, gave better results than the position of Group II. According to our results, if a lung board will be used, adding the arm supporting accessory will be necessary. Random errors can be minimized and the set-up quality improved by using appropriate immobilization devices, minimizing the total set-up time and balancing the in and outdoor temperature by air conditioning system.
引用
收藏
页码:394 / 402
页数:9
相关论文
共 50 条
  • [21] FAST EVALUATION OF PATIENT SET-UP DURING RADIOTHERAPY BY ALIGNING FEATURES IN PORTAL AND SIMULATOR IMAGES
    BIJHOLD, J
    VANHERK, M
    VIJLBRIEF, R
    LEBESQUE, JV
    PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (12): : 1665 - 1679
  • [22] Margin evaluation of translational and rotational set-up errors in intensity modulated radiotherapy for cervical cancer
    Zhang, Xiang
    Shan, Guo-ping
    Liu, Ji-ping
    Wang, Bin-bing
    SPRINGERPLUS, 2016, 5 : 1 - 9
  • [23] Set-up uncertainty during breast radiotherapy Image-guided radiotherapy for patients with initial extensive variation
    Yang, D. S.
    Yoon, W. S.
    Chung, S. Y.
    Lee, J. A.
    Lee, S.
    Park, Y. J.
    Kim, C. Y.
    Son, G. S.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2013, 189 (04) : 315 - 320
  • [24] Organ motion, set-up variation and treatment margins in radical radiotherapy of urinary bladder cancer
    Muren, LP
    Smaaland, R
    Dahl, O
    RADIOTHERAPY AND ONCOLOGY, 2003, 69 (03) : 291 - 304
  • [25] Assessment of set-up discrepancies using daily portal imaging during radiotherapy treatment for patients with spine and bone metastases
    Young, L.
    Blyth, C. M.
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2012, 11 (04) : 209 - 216
  • [26] Evaluation of set up margins and a correction protocol in radical radiotherapy for lung cancer
    Minchell, L.
    Whitehurst, P.
    Faivre-Finn, C.
    Bayman, N.
    Choudhury, A.
    Stratford, J.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S140 - S141
  • [27] Extended Analysis of Hypofractionated Radiotherapy Set-up Parameters for Breast Cancer Patients on the FAST Trial
    Thomson, A. H.
    Culley, M.
    CLINICAL ONCOLOGY, 2009, 21 (03) : 279 - 279
  • [28] Set-up accuracy of an external immobilisation system for patients receiving radical radiotherapy for prostate cancer
    d'Aquino, Ashley
    Harrison, Shalini
    Helyer, Sarah
    Dearnaley, David
    McNair, Helen
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2012, 11 (03) : 155 - 161
  • [29] Analysis of Set-up Errors during CT-scan, Simulation, and Treatment Process in Breast Cancer Patients
    Lee, Rena
    RADIATION ONCOLOGY JOURNAL, 2005, 23 (03): : 169 - 175
  • [30] Improving the set-up of breast cancer patients during radiation treatment using an optical surface scanning system
    Thornberg, C.
    Kugele, M.
    Edvardsson, A.
    Ceberg, S.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S222 - S222