Comparison between the ROI based and pixel based analysis for neuroreceptor studies performed on the high resolution research tomograph (HRRT)

被引:0
|
作者
Sossi, Vesna [1 ]
Blinder, Stephan [2 ]
Dinelle, Katherine [1 ]
Lidstone, Sarah [1 ]
Cheng, Kevin J-C [1 ]
Rahmim, Arman [1 ,3 ]
McCormick, Siobhan [2 ]
Doudet, Doris J. [1 ]
Ruth, Thomas J. [4 ]
机构
[1] Univ British Columbia, Vancouver, BC V6T 1Z1, Canada
[2] Pacific Parkinsons Res Ctr, Vancouver, BC V6T 1Z1, Canada
[3] Johns Hopkins Univ, Sch Med, Dept Radiol, Baltimore, MD 21205 USA
[4] TRIUMF, Vancouver, BC V6T 1Z1, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
D O I
10.1109/NSSMIC.2006.356427
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Parametric imaging refers to evaluating kinetic model parameters from time activity curves (TACs) estimated from every image pixel in contrast to region of interest (ROI) based analysis where the parameters are evaluated from TACs derived from predefined ROIs. Parametric imaging is thus more sensitive to statistical and motion induced noise. Here we evaluate the feasibility of parametric imaging for two modeling approaches, the simplified reference tissue model (RTM) and the tissue input Logan graphical method (L), for data acquired on the high resolution research tomograph (HRRT). The small image pixel size of this tomograph makes the image pixel values particularly sensitive to statistical noise and to artifacts due to subject motion. Comparing parametric BP estimates to those obtained with the ROI based approach a large downward bias (up to 28%) was observed for the Logan approach, while no bias was observed for the RTM method. The correlation between the BP values obtained with the ROI and parametric approach was better and less affected by motion for RTM (r(2) > 0.9) compared to L (r(2) > 0.45). The correlation between the BP obtained with the two methods was found to be significantly affected by patient motion and in general better for the ROI based approach. We conclude that parametric imaging on the HRRT is feasible for selected modeling approaches.
引用
收藏
页码:2653 / 2657
页数:5
相关论文
共 50 条
  • [1] Evaluation of the Depth of Interaction (DOI) for the High Resolution Research Tomograph (HRRT) - a comparison between scanners with and without DOI
    Knoess, C
    Boellaard, R
    Lenox, M
    Vollmar, S
    Casey, M
    Fluegge, G
    Lammertsma, A
    Wienhard, K
    Heiss, WD
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 1447 - 1451
  • [2] Dynamic imaging on the high resolution research tomograph(HRRT): Non-human primate studies
    Sossi, Vesna
    Camborde, Marie-Laure
    Blinder, Stephan
    Rahmim, A.
    Cheng, Kevin J. -C.
    Buckley, Ken R.
    Doudet, Doris J.
    Ruth, Thomas J.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 1981 - 1985
  • [3] Point Spread Function Reconstruction of High-Resolution Research Tomograph - HRRT - PET-Images Improves In Vivo Neuroreceptor Quantification
    Varrone, A.
    Sjoholm, N.
    Gulyas, B.
    Halldin, C.
    Farde, L.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 : S145 - S145
  • [4] Influence of Outside Field of View Activity on the Quality of High Resolution Research Tomograph (HRRT) Brain studies
    Kloet, Reina W.
    de Jong, Hugo W. A. M.
    van Velden, Floris H. P.
    Lammertsma, Adriaan A.
    Boellaard, Ronald
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3369 - 3371
  • [5] Scanning rats on the high resolution research tomograph (HRRT): A comparison study with a dedicated micro-PET
    Blinder, Stephan A. L.
    Dinelle, Katherine
    Sossi, Vesna
    MEDICAL PHYSICS, 2012, 39 (08) : 5073 - 5083
  • [6] Effect of measurement uncertainty on region of interest based and parametric binding potential estimates for the high resolution research tomograph (HRRT)
    Sossi, Vesna
    Blinder, Stephan
    Rahmim, Arman
    Dinelle, Katherine
    Cheng, Kevin J-C
    Lidstone, Sarah C.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 4539 - +
  • [7] Comparison of pixel based and feature based fusion of high resolution optical and SAR imagery
    Atay, G.
    Wegner, J. D.
    Lohmann, P.
    Hofmann, P.
    Soergel, U.
    REMOTE SENSING FOR A CHANGING EUROPE, 2009, : 214 - 219
  • [8] COMPARISON BETWEEN PIXEL AND REGION BASED SITS ANALYSIS APPROACHES
    Rejichi, S.
    Chaabane, F.
    Tupin, F.
    2017 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM (IGARSS), 2017, : 1934 - 1937
  • [9] Comparison of pixel-based fusion between multi-spectral data and high spatial resolution data
    Zhao, SH
    Wang, ZY
    Dong, XQ
    Chen, XW
    IMAGE PROCESSING AND PATTERN RECOGNITION IN REMOTE SENSING II, 2005, 5657 : 99 - 106
  • [10] A comparison of object-based and contextual pixel-based classifications using high and medium spatial resolution images
    Cai, Shanshan
    Liu, Desheng
    REMOTE SENSING LETTERS, 2013, 4 (10) : 998 - 1007