Comparison between the ROI based and pixel based analysis for neuroreceptor studies performed on the high resolution research tomograph (HRRT)

被引:0
|
作者
Sossi, Vesna [1 ]
Blinder, Stephan [2 ]
Dinelle, Katherine [1 ]
Lidstone, Sarah [1 ]
Cheng, Kevin J-C [1 ]
Rahmim, Arman [1 ,3 ]
McCormick, Siobhan [2 ]
Doudet, Doris J. [1 ]
Ruth, Thomas J. [4 ]
机构
[1] Univ British Columbia, Vancouver, BC V6T 1Z1, Canada
[2] Pacific Parkinsons Res Ctr, Vancouver, BC V6T 1Z1, Canada
[3] Johns Hopkins Univ, Sch Med, Dept Radiol, Baltimore, MD 21205 USA
[4] TRIUMF, Vancouver, BC V6T 1Z1, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
D O I
10.1109/NSSMIC.2006.356427
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Parametric imaging refers to evaluating kinetic model parameters from time activity curves (TACs) estimated from every image pixel in contrast to region of interest (ROI) based analysis where the parameters are evaluated from TACs derived from predefined ROIs. Parametric imaging is thus more sensitive to statistical and motion induced noise. Here we evaluate the feasibility of parametric imaging for two modeling approaches, the simplified reference tissue model (RTM) and the tissue input Logan graphical method (L), for data acquired on the high resolution research tomograph (HRRT). The small image pixel size of this tomograph makes the image pixel values particularly sensitive to statistical noise and to artifacts due to subject motion. Comparing parametric BP estimates to those obtained with the ROI based approach a large downward bias (up to 28%) was observed for the Logan approach, while no bias was observed for the RTM method. The correlation between the BP values obtained with the ROI and parametric approach was better and less affected by motion for RTM (r(2) > 0.9) compared to L (r(2) > 0.45). The correlation between the BP obtained with the two methods was found to be significantly affected by patient motion and in general better for the ROI based approach. We conclude that parametric imaging on the HRRT is feasible for selected modeling approaches.
引用
收藏
页码:2653 / 2657
页数:5
相关论文
共 50 条
  • [31] A Radar-Based Concept for Simultaneous High-Resolution Imaging and Pixel-Wise Velocity Analysis for Tracking Human Motion
    Braeunig, Johanna
    Heinrich, Simon
    Coppers, Birte
    Kammel, Christoph
    Wirth, Vanessa
    Stamminger, Marc
    Leyendecker, Sigrid
    Liphardt, Anna-Maria
    Ullmann, Ingrid
    Vossiek, Martin
    IEEE JOURNAL OF MICROWAVES, 2024, 4 (04): : 639 - 652
  • [32] Comparison of Public Policy Research Issue between China and US based on Content Analysis Method
    Lin, Ting
    2014 2ND INTERNATIONAL CONFERENCE ON ECONOMIC, BUSINESS MANAGEMENT AND EDUCATION INNOVATION (EBMEI 2014), VOL 36, 2014, 36 : 290 - 294
  • [33] Traceability Research on Geographic Erigeron breviscapus Based on High-Resolution Mass Spectrometry and Chemometric Analysis
    Zhang, Jiao
    Tian, Heng
    Lin, Tao
    Huang, Xiangzhong
    Liu, Hongcheng
    MOLECULES, 2024, 29 (12):
  • [34] Discrimination Between Solitary Brain Metastasis and Glioblastoma Multiforme by Using ADC-Based Texture Analysis: A Comparison of Two Different ROI Placements
    Zhang, Guoqin
    Chen, Xin
    Zhang, Sijing
    Ruan, Xiuhang
    Gao, Cuihua
    Liu, Zaiyi
    Wei, Xinhua
    ACADEMIC RADIOLOGY, 2019, 26 (11) : 1466 - 1472
  • [35] A comparison between high-resolution central and Godunov-based schemes for the black-oil simulation
    Karimi, A.
    Naderan, H.
    Manzari, M. T.
    Hannam, S. K.
    INTERNATIONAL JOURNAL OF NUMERICAL METHODS FOR HEAT & FLUID FLOW, 2009, 19 (02) : 125 - 145
  • [36] A comparison between Pixel-based deep learning and Object-based image analysis (OBIA) for individual detection of cabbage plants based on UAV Visible-light images
    Ye, Zhangxi
    Yang, Kaile
    Lin, Yuwei
    Guo, Shijie
    Sun, Yiming
    Chen, Xunlong
    Lai, Riwen
    Zhang, Houxi
    COMPUTERS AND ELECTRONICS IN AGRICULTURE, 2023, 209
  • [37] Pixel-wise kinetic analysis for the M1 muscarinic acetylcholine receptor PET radiotracer 11C-LSN3172176: comparison with ROI-based results
    Bao, Weiqi
    Naganawa, Mika
    Nabulsi, Nabeel
    Lin, Shu-fei
    Slieker, Lawrence
    Schwarz, Adam
    Kant, Nancy
    Ropchan, Jim
    Huang, Yiyun
    Carson, Richard
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59
  • [38] Object-based change detection of very high-resolution remote sensing images incorporating multiscale uncertainty analysis by fusing pixel-based change detection
    Cao, Jian Nong
    Liao, Juan
    Zhang, Bao Jin
    Wang, Kun
    Zhao, WeiHeng
    JOURNAL OF ELECTRONIC IMAGING, 2021, 30 (05)
  • [39] A CsI(Na) based radiation detector for high resolution imaging studies using iodine 125 in small animal research
    Weisenberger, A
    Bradley, E
    Majewski, S
    Saha, M
    HARD X-RAY AND GAMMA-RAY DETECTOR PHYSICS, OPTICS, AND APPLICATIONS, 1997, 3115 : 254 - 262
  • [40] Combining pixel and object based image analysis of ultra-high resolution multibeam bathymetry and backscatter for habitat mapping in shallow marine waters
    Daniel Ierodiaconou
    Alexandre C. G. Schimel
    David Kennedy
    Jacquomo Monk
    Grace Gaylard
    Mary Young
    Markus Diesing
    Alex Rattray
    Marine Geophysical Research, 2018, 39 : 271 - 288