Comparison between the ROI based and pixel based analysis for neuroreceptor studies performed on the high resolution research tomograph (HRRT)

被引:0
|
作者
Sossi, Vesna [1 ]
Blinder, Stephan [2 ]
Dinelle, Katherine [1 ]
Lidstone, Sarah [1 ]
Cheng, Kevin J-C [1 ]
Rahmim, Arman [1 ,3 ]
McCormick, Siobhan [2 ]
Doudet, Doris J. [1 ]
Ruth, Thomas J. [4 ]
机构
[1] Univ British Columbia, Vancouver, BC V6T 1Z1, Canada
[2] Pacific Parkinsons Res Ctr, Vancouver, BC V6T 1Z1, Canada
[3] Johns Hopkins Univ, Sch Med, Dept Radiol, Baltimore, MD 21205 USA
[4] TRIUMF, Vancouver, BC V6T 1Z1, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
D O I
10.1109/NSSMIC.2006.356427
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Parametric imaging refers to evaluating kinetic model parameters from time activity curves (TACs) estimated from every image pixel in contrast to region of interest (ROI) based analysis where the parameters are evaluated from TACs derived from predefined ROIs. Parametric imaging is thus more sensitive to statistical and motion induced noise. Here we evaluate the feasibility of parametric imaging for two modeling approaches, the simplified reference tissue model (RTM) and the tissue input Logan graphical method (L), for data acquired on the high resolution research tomograph (HRRT). The small image pixel size of this tomograph makes the image pixel values particularly sensitive to statistical noise and to artifacts due to subject motion. Comparing parametric BP estimates to those obtained with the ROI based approach a large downward bias (up to 28%) was observed for the Logan approach, while no bias was observed for the RTM method. The correlation between the BP values obtained with the ROI and parametric approach was better and less affected by motion for RTM (r(2) > 0.9) compared to L (r(2) > 0.45). The correlation between the BP obtained with the two methods was found to be significantly affected by patient motion and in general better for the ROI based approach. We conclude that parametric imaging on the HRRT is feasible for selected modeling approaches.
引用
收藏
页码:2653 / 2657
页数:5
相关论文
共 50 条
  • [41] Combining pixel and object based image analysis of ultra-high resolution multibeam bathymetry and backscatter for habitat mapping in shallow marine waters
    Ierodiaconou, Daniel
    Schimel, Alexandre C. G.
    Kennedy, David
    Monk, Jacquomo
    Gaylard, Grace
    Young, Mary
    Diesing, Markus
    Rattray, Alex
    MARINE GEOPHYSICAL RESEARCH, 2018, 39 (1-2) : 271 - 288
  • [42] APPLICATIONS OF LAND-BASED HIGH-RESOLUTION SEISMIC-REFLECTION ANALYSIS TO QUATERNARY AND GEOMORPHIC RESEARCH
    ROBERTS, MC
    PULLAN, SE
    HUNTER, JA
    QUATERNARY SCIENCE REVIEWS, 1992, 11 (05) : 557 - 568
  • [43] A Comparison Between High-Resolution EO-Based and Ice Analyst-Assigned Sea Ice Concentrations
    Karvonen, Juha
    Vainio, Jouni
    Marnela, Marika
    Eriksson, Patrick
    Niskanen, Tuomas
    IEEE JOURNAL OF SELECTED TOPICS IN APPLIED EARTH OBSERVATIONS AND REMOTE SENSING, 2015, 8 (04) : 1799 - 1807
  • [44] Comparison of pixel unmixing models in the evaluation of post-fire forest resilience based on temporal series of satellite imagery at moderate and very high spatial resolution
    Manuel Fernandez-Guisuraga, Jose
    Calvo, Leonor
    Suarez-Seoane, Susana
    ISPRS JOURNAL OF PHOTOGRAMMETRY AND REMOTE SENSING, 2020, 164 : 217 - 228
  • [45] Comparison of research trends and hotspots of DNA and RNA methylation in asthma-related studies based on bibliometric analysis
    Du, Junbao
    Gong, Lifen
    Wang, Jialiang
    Zhang, Ziwei
    Cheng, Hang
    DISCOVER APPLIED SCIENCES, 2025, 7 (03)
  • [46] Analysis of Correlation between the Number of Lenticulostriate Arteries and Hypertension Based on High-Resolution MR Angiography Findings
    Chen, Y-c.
    Li, M. -h.
    Li, Y-h.
    Qiao, R. -h.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (10) : 1899 - 1903
  • [47] Surface structure of imidazolium-based ionic liquids: Quantitative comparison between simulations and high-resolution RBS measurements
    Nakajima, Kaoru
    Nakanishi, Shunto
    Lisal, Martin
    Kimura, Kenji
    JOURNAL OF CHEMICAL PHYSICS, 2016, 144 (11):
  • [48] Studies of High Spectral Resolution Atmospheric Sounding Data Compression and Noise Reduction Based on Principal Component Analysis Method
    Zhang Shuiping
    Zhang Shuiping
    PROCEEDINGS OF THE 2009 2ND INTERNATIONAL CONGRESS ON IMAGE AND SIGNAL PROCESSING, VOLS 1-9, 2009, : 4693 - +
  • [49] Comparison of Outcomes Between Transperitoneal and Retroperitoneal Robotic Partial Nephrectomy: A Meta-Analysis Based on Comparative Studies
    Zhu, Daqing
    Shao, Xue
    Guo, Gang
    Zhang, Nandong
    Shi, Taoping
    Wang, Yi
    Gu, Liangyou
    FRONTIERS IN ONCOLOGY, 2021, 10
  • [50] A comparative analysis of different pixel and object-based classification algorithms using multi-source high spatial resolution satellite data for LULC mapping
    Balha, Akanksha
    Mallick, Javed
    Pandey, Suneel
    Gupta, Sandeep
    Singh, Chander Kumar
    EARTH SCIENCE INFORMATICS, 2021, 14 (04) : 2231 - 2247