Point Spread Function Reconstruction of High-Resolution Research Tomograph - HRRT - PET-Images Improves In Vivo Neuroreceptor Quantification

被引:0
|
作者
Varrone, A.
Sjoholm, N.
Gulyas, B.
Halldin, C.
Farde, L.
机构
[1] Karolinska Inst, Dept Clin Neurosci, Stockholm, Sweden
[2] Stockholm Brain Inst, Stockholm, Sweden
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
引用
收藏
页码:S145 / S145
页数:1
相关论文
共 50 条
  • [1] Scanning Rodents on the High Resolution Research Tomograph (HRRT) with Point Spread Function Reconstruction: a Feasibility Study
    Blinder, Stephan A. L.
    Dinelle, Katherine
    Sossi, Vesna
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3333 - 3338
  • [2] The ECAT HRRT: NEMA NEC evaluation of the HRRT system, the new high-resolution research tomograph
    Eriksson, L
    Wienhard, K
    Eriksson, M
    Casey, ME
    Knoess, C
    Bruckbauer, T
    Hamill, J
    Schmand, M
    Gremillion, T
    Lenox, M
    Conti, M
    Bendriem, B
    Heiss, WD
    Nutt, R
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (05) : 2085 - 2088
  • [3] Advancement in PET quantification using 3D-OP-OSEM point spread function reconstruction with the HRRT
    Andrea Varrone
    Nils Sjöholm
    Lars Eriksson
    Balazs Gulyás
    Christer Halldin
    Lars Farde
    European Journal of Nuclear Medicine and Molecular Imaging, 2009, 36 : 1639 - 1650
  • [4] Advancement in PET quantification using 3D-OP-OSEM point spread function reconstruction with the HRRT
    Varrone, Andrea
    Sjoholm, Nils
    Eriksson, Lars
    Gulyas, Balazs
    Halldin, Christer
    Farde, Lars
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 (10) : 1639 - 1650
  • [5] Comparison between the ROI based and pixel based analysis for neuroreceptor studies performed on the high resolution research tomograph (HRRT)
    Sossi, Vesna
    Blinder, Stephan
    Dinelle, Katherine
    Lidstone, Sarah
    Cheng, Kevin J-C
    Rahmim, Arman
    McCormick, Siobhan
    Doudet, Doris J.
    Ruth, Thomas J.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2653 - 2657
  • [6] Characteristics of a single LSO crystal layer high resolution research tomograph (HRRT) PET scanner.
    Boellaard, R
    Buijs, F
    Lenox, N
    Casey, ME
    Gremillion, T
    Jagt, P
    Lammertsma, AA
    JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (05) : 226P - 227P
  • [7] Scanning rats on the high resolution research tomograph (HRRT): A comparison study with a dedicated micro-PET
    Blinder, Stephan A. L.
    Dinelle, Katherine
    Sossi, Vesna
    MEDICAL PHYSICS, 2012, 39 (08) : 5073 - 5083
  • [8] High resolution image reconstruction (point spread function based) in FDG brain PET
    Reimold, Matthias
    Pfannenberg, Christina
    Kupferschlaeger, Jurgen
    Bares, Roland
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [9] Performance results of a new DOI detector block for a High Resolution PET-LSO Research Tomograph HRRT
    Schmand, M
    Eriksson, L
    Casey, ME
    Andreaco, MS
    Melcher, C
    Wienhard, K
    Flügge, G
    Nutt, R
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (06) : 3000 - 3006
  • [10] Performance results of a new DOI detector block for a high resolution PET-LSO research tomograph HRRT
    Schmand, M
    Eriksson, L
    Casey, ME
    Andreaco, MS
    Melcher, C
    Wienhard, K
    Flugge, G
    Nutt, R
    1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 934 - 938