Monte-Carlo Simulation Based Estimation of NECR, Sensitivity, and Spatial Resolution of a Novel Preclinical PET Insert for MR

被引:0
|
作者
Becker, Robert [1 ]
Cachemiche, Jean-Pierre [2 ]
Casella, Chiara [1 ]
Dissertori, Guenther [1 ]
Fischer, Jannis [1 ]
Howard, Alexander S. [1 ]
Kramer, Kevin [1 ]
Lustermann, Werner [1 ]
Morel, Christian [2 ]
Oliver, Josep F. [3 ]
Roser, Ulf [1 ]
Wang, Qiulin [1 ,4 ]
Weber, Bruno [5 ]
机构
[1] ETH, Inst Particle Phys, Otto Stern Weg 5, CH-8093 Zurich, Switzerland
[2] Aix Marseille Univ, CNRS IN2P3, CPPM UMR 7346, Marseille, France
[3] Inst Fis Corpuscular, E-46071 Valencia, Spain
[4] Tsinghua Univ, Inst Med Phys, Beijing, Peoples R China
[5] Univ Zurich, Inst Pharmacol & Toxicol, CH-8057 Zurich, Switzerland
关键词
PET insert; high-rate; preclinical;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The Small Animal Fast Insert for mRi (SAFIR) will be a PET insert for the Bruker BioSpin 70/30. It aims at applications where fast processes such as blood perfusion in the rodent brain are to be monitored comprehensively and non-invasively. Employing electronics originally designed for time-of-flight applications, coincidence resolving times of less than a nanosecond can be achieved allowing for short coincidence time windows. Consequently, random contributions to the coincidence events are suppressed, making short acquisition frames with very high tracer concentrations possible. This will allow collecting sufficient count statistics in a few seconds. Geant4-based Monte Carlo simulations were used to characterize the performance of the reference design consisting of polished LSO-like crystals, one-to-one coupled to Silicon Photomultipliers. The crystals are grouped into 8 x 8 matrices, which are arranged into 24 modules and 10 rings. Similar methods as described in the NEMA NU 4-2008 standard were employed. The simulation results on NECR, sensitivity, and spatial resolution will be presented. Most notably, the NECR at 500 MBq is almost nine times higher than at 50 MBq for the given scanner. Combined with a very high sensitivity, this allows for short acquisition times using these very high injected doses. In addition, essentially random-free measurements at standard activities below 50 MBq are possible.
引用
收藏
页数:3
相关论文
共 46 条
  • [21] Assessment of the spatial resolution of PET scanners using a Geant4-based Monte Carlo tool
    Fiedler, K
    Frach, T
    Rütten, W
    Solf, T
    Thon, A
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2549 - 2553
  • [22] Optimized Parallel-Hole Collimator Design that Balances Spatial Resolution and Sensitivity through Monte Carlo Simulation
    Kang, Seung-Hun
    Jo, Byungdu
    Lee, Seung-Jae
    JOURNAL OF MAGNETICS, 2023, 28 (04) : 415 - 419
  • [24] ESTIMATION OF SCATTERING PROPERTIES OF LITHOSPHERE OF KAMCHATKA BASED ON MONTE-CARLO SIMULATION OF RECORD ENVELOPE OF A NEAR EARTHQUAKE
    ABUBAKIROV, IR
    GUSEV, AA
    PHYSICS OF THE EARTH AND PLANETARY INTERIORS, 1990, 64 (01) : 52 - 67
  • [25] Performance estimation of optical skin probe in short wavelength infrared spectroscopy based on Monte-Carlo simulation
    Lee, June-Young
    Ahn, Sungmo
    Nam, Sung Hyun
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [26] Performance estimation of optical skin probe in short wavelength infrared spectroscopy based on Monte-Carlo simulation
    June-Young Lee
    Sungmo Ahn
    Sung Hyun Nam
    Scientific Reports, 12
  • [27] Novel preclinical PET geometrical concept using a monolithic scintillator crystal offering concurrent enhancement in spatial resolution and detection sensitivity: a simulation study
    Sanaat, Amirhossein
    Arabi, Hossein
    Ay, Mohammad Reza
    Zaidi, Habib
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (04):
  • [28] Preclinical voxel-based dosimetry through GATE Monte Carlo simulation using PET/CT imaging of mice
    Gupta, Arun
    Lee, Min Sun
    Kim, Joong Hyun
    Park, Sohyeon
    Park, Hyun Soo
    Kim, Sang Eun
    Lee, Dong Soo
    Lee, Jae Sung
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (09):
  • [29] Image based preclinical absorbed dose estimation through GATE Monte Carlo simulation using 18F-FDG PET/CT images of mice
    Gupta, A.
    Lee, M. S.
    Kim, J. H.
    Park, S. H.
    Park, H. S.
    Kim, S. E.
    Lee, D. S.
    Lee, J. S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 : S357 - S357
  • [30] A comparison of BGO, GSO and LSO crystals in photopeak efficiency and spatial resolution for a high resolution animal PET scanner using Monte Carlo Simulation.
    Baghaei, H
    Wong, WH
    Uribe, J
    Li, H
    Wang, Y
    Liu, Y
    Xing, T
    Farrell, R
    Xie, S
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 284P - 284P