Monte-Carlo Simulation Based Estimation of NECR, Sensitivity, and Spatial Resolution of a Novel Preclinical PET Insert for MR

被引:0
|
作者
Becker, Robert [1 ]
Cachemiche, Jean-Pierre [2 ]
Casella, Chiara [1 ]
Dissertori, Guenther [1 ]
Fischer, Jannis [1 ]
Howard, Alexander S. [1 ]
Kramer, Kevin [1 ]
Lustermann, Werner [1 ]
Morel, Christian [2 ]
Oliver, Josep F. [3 ]
Roser, Ulf [1 ]
Wang, Qiulin [1 ,4 ]
Weber, Bruno [5 ]
机构
[1] ETH, Inst Particle Phys, Otto Stern Weg 5, CH-8093 Zurich, Switzerland
[2] Aix Marseille Univ, CNRS IN2P3, CPPM UMR 7346, Marseille, France
[3] Inst Fis Corpuscular, E-46071 Valencia, Spain
[4] Tsinghua Univ, Inst Med Phys, Beijing, Peoples R China
[5] Univ Zurich, Inst Pharmacol & Toxicol, CH-8057 Zurich, Switzerland
关键词
PET insert; high-rate; preclinical;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The Small Animal Fast Insert for mRi (SAFIR) will be a PET insert for the Bruker BioSpin 70/30. It aims at applications where fast processes such as blood perfusion in the rodent brain are to be monitored comprehensively and non-invasively. Employing electronics originally designed for time-of-flight applications, coincidence resolving times of less than a nanosecond can be achieved allowing for short coincidence time windows. Consequently, random contributions to the coincidence events are suppressed, making short acquisition frames with very high tracer concentrations possible. This will allow collecting sufficient count statistics in a few seconds. Geant4-based Monte Carlo simulations were used to characterize the performance of the reference design consisting of polished LSO-like crystals, one-to-one coupled to Silicon Photomultipliers. The crystals are grouped into 8 x 8 matrices, which are arranged into 24 modules and 10 rings. Similar methods as described in the NEMA NU 4-2008 standard were employed. The simulation results on NECR, sensitivity, and spatial resolution will be presented. Most notably, the NECR at 500 MBq is almost nine times higher than at 50 MBq for the given scanner. Combined with a very high sensitivity, this allows for short acquisition times using these very high injected doses. In addition, essentially random-free measurements at standard activities below 50 MBq are possible.
引用
收藏
页数:3
相关论文
共 46 条
  • [31] Reference rodent S-values based on Monte-Carlo simulation with GATE (v6.1) for radionuclides of interest in μ-PET imaging
    Mauxion, T.
    Barbet, J.
    Suhard, J.
    Bardies, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S199 - S200
  • [32] Active-PET: a multifunctional PET scanner with dynamic gantry size featuring high-resolution and high-sensitivity imaging: a Monte Carlo simulation study
    Sanaat, Amirhossein
    Jamalizadeh, Mahdi
    Khanmohammadi, Hadi
    Arabi, Hossein
    Zaidi, Habib
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (15):
  • [33] Comparison of a GATE Monte Carlo Simulation Predictions to the Performance of a High-Resolution LYSO Based Dedicated Animal PET Camera
    Baghaei, Hossain
    Zhang, Yuxuan
    Li, Hongdi
    Ramirez, Rocio A.
    Liu, Shitao
    Wang, Chao
    An, Shaohui
    Wong, Wai-Hoi
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2388 - 2392
  • [34] Design and Performance evaluation of a Novel Brain PET Geometry Based on Partial Cylindrical Detector using Monte Carlo simulation
    Sheikhzadeh, P.
    Sabet, H.
    Ghadiri, H.
    Ghafarian, P.
    Ay, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S94 - S94
  • [35] Expected accuracy of tilt measurements on a novel hexapod-based digital zenith camera system: a Monte-Carlo simulation study
    Hirt, Christian
    Papp, Gabor
    Pal, Andras
    Benedek, Judit
    Szucs, Eszter
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2014, 25 (08)
  • [36] A Novel Iterative Image Reconstruction Method for High-Resolution PET Imaging with a Monte Carlo Based Positron Range Model
    Fu, Lin
    Qi, Jinyi
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 2884 - 2887
  • [37] Impact of respiratory motion correction and spatial resolution on lesion detection in PET: a simulation study based on real MR dynamic data
    Polycarpou, Irene
    Tsoumpas, Charalampos
    King, Andrew P.
    Marsden, Paul K.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (03): : 697 - 713
  • [38] Water quality evaluation and non-cariogenic risk assessment of exposure to nitrate in groundwater resources of Kamyaran, Iran: spatial distribution, Monte-Carlo simulation, and sensitivity analysis
    Arsalan Jamshidi
    Maryam Morovati
    Mohammad Mehdi Golbini Mofrad
    Maryam Panahandeh
    Hamed Soleimani
    Halimeh Abdolahpour Alamdari
    Journal of Environmental Health Science and Engineering, 2021, 19 : 1117 - 1131
  • [39] Water quality evaluation and non-cariogenic risk assessment of exposure to nitrate in groundwater resources of Kamyaran, Iran: spatial distribution, Monte-Carlo simulation, and sensitivity analysis
    Jamshidi, Arsalan
    Morovati, Maryam
    Mofrad, Mohammad Mehdi Golbini
    Panahandeh, Maryam
    Soleimani, Hamed
    Alamdari, Halimeh Abdolahpour
    JOURNAL OF ENVIRONMENTAL HEALTH SCIENCE AND ENGINEERING, 2021, 19 (01) : 1117 - 1131
  • [40] The evaluation of the spatial resolution of 11C-, 18F- and 64Cu-PET images on a clinical PET/CT scanner using Monte Carlo Simulation and phantom examination
    Kimoto, Saki
    Hashimoto, Naoki
    Shoji, Ayano
    Tsutsui, Yuji
    Himuro, Kazuhiko
    Baba, Shingo
    Takahashi, Akihiko
    Sasaki, Masayuki
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59