A comparison of BGO, GSO and LSO crystals in photopeak efficiency and spatial resolution for a high resolution animal PET scanner using Monte Carlo Simulation.

被引:0
|
作者
Baghaei, H [1 ]
Wong, WH [1 ]
Uribe, J [1 ]
Li, H [1 ]
Wang, Y [1 ]
Liu, Y [1 ]
Xing, T [1 ]
Farrell, R [1 ]
Xie, S [1 ]
机构
[1] Univ Texas, MD Anderson Canc Ctr, Houston, TX 77030 USA
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
1019
引用
收藏
页码:284P / 284P
页数:1
相关论文
共 50 条
  • [1] A comparison of BGO, GSO, MLS, LGSO, LYSO and LSO scintillation materials for high-spatial-resolution animal PET detectors
    Ramirez, Rocio A.
    Wong, Wai-Hoi
    Kim, Soonseok
    Baghaei, Hossain
    Li, Hongdi
    Wang, Yu
    Zhang, Yuxuan
    Liu, Shitao
    Liu, Jiguo
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2835 - 2839
  • [2] Energy and spatial resolution relationship comparison study on BGO, GSO and LSO.
    Wang, Y
    Wong, W
    Uribe, J
    Li, H
    Baghaei, H
    Liu, Y
    Xing, T
    Farrell, R
    Xie, S
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 283P - 284P
  • [3] Comparison of LuYAP, LSO, and BGO as scintillators for high resolution PET detectors
    Weber, S
    Christ, D
    Kurzeja, M
    Engels, R
    Kemmerling, G
    Hailing, H
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (05) : 1370 - 1372
  • [4] Comparison of LuYAP, LSO and BGO as scintillators for high resolution PET detectors
    Weber, S
    Christ, D
    Kurzeja, M
    Engels, R
    Kemmerling, G
    Halling, H
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 1640 - 1642
  • [5] Energy resolution and absolute detection efficiency for LSO crystals: A comparison between Monte Carlo simulation and experimental data
    Rothfuss, Harold
    Byars, Larry
    Casey, Michael E.
    Conti, Maurizio
    Eriksson, Lars
    Michel, Christian
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (02): : 1087 - 1092
  • [6] GATE Monte Carlo simulation of a high-sensitivity and high-resolution LSO-based small animal PET camera
    Baghaei, Flossain
    Zhang, Yuxuan
    Li, Hongdi
    Wang, Yu
    Kim, Soonseok
    Ramirez, Rocio A.
    Liu, Jiguo
    Liu, Shitao
    Wong, Wai-Hoi
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2007, 54 (05) : 1568 - 1573
  • [7] A GATE Monte Carlo Simulation of the Performance of a High-Sensitivity and High-Resolution LSO Based Small Animal PET Camera
    Baghaei, Hossain
    Zhang, Yuxuan
    Li, Hongdi
    Wang, Yu
    Kim, Soonseok
    Ramirez, Rocio
    Liu, Jiguo
    Liu, Shitao
    Wong, Wai-Hoi
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2476 - 2479
  • [8] A high resolution animal PET: Using continuous LSO with intrinsic spatial resolution approaching 1 mm.
    Joung, J
    Miyaoka, RS
    Kohlmyer, SG
    Lewellen, TK
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (05) : 55P - 56P
  • [9] MadPET: High resolution animal pet with avalanche photodiode arrays and LSO crystals.
    Ziegler, SI
    Pichler, BJ
    Boening, G
    Rafecas, H
    Bieler, S
    Pimpl, W
    Lorenz, E
    Schwaiger, M
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 20P - 20P
  • [10] A Monte Carlo investigation of the spatial resolution performance of a small-animal PET scanner designed for mouse brain imaging studies
    Rodriguez-Villafuerte, Mercedes
    Yang, Yongfeng
    Cherry, Simon R.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (01): : 76 - 85