A comparison of BGO, GSO and LSO crystals in photopeak efficiency and spatial resolution for a high resolution animal PET scanner using Monte Carlo Simulation.

被引:0
|
作者
Baghaei, H [1 ]
Wong, WH [1 ]
Uribe, J [1 ]
Li, H [1 ]
Wang, Y [1 ]
Liu, Y [1 ]
Xing, T [1 ]
Farrell, R [1 ]
Xie, S [1 ]
机构
[1] Univ Texas, MD Anderson Canc Ctr, Houston, TX 77030 USA
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
1019
引用
收藏
页码:284P / 284P
页数:1
相关论文
共 50 条
  • [31] The evaluation of the spatial resolution of 11C-, 18F- and 64Cu-PET images on a clinical PET/CT scanner using Monte Carlo Simulation and phantom examination
    Kimoto, Saki
    Hashimoto, Naoki
    Shoji, Ayano
    Tsutsui, Yuji
    Himuro, Kazuhiko
    Baba, Shingo
    Takahashi, Akihiko
    Sasaki, Masayuki
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59
  • [32] High resolution GSO block detectors using PMT-Quadrant-Sharing design for small animal PET
    Kim, S
    Wong, WH
    Xie, SP
    Ramirez, R
    Liu, YQ
    Li, HD
    Xing, T
    Wang, Y
    Uribe, J
    Baghaei, H
    Zhang, YX
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (01) : 40 - 43
  • [33] High resolution GSO block detectors using PMT-Quadrant-Sharing design for small animal PET
    Kim, S
    Wong, WH
    Xie, SP
    Ramirez, R
    Liu, YQ
    Li, HD
    Xing, T
    Wang, Y
    Uribe, J
    Baghaei, H
    Zhang, YX
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3385 - 3388
  • [34] Resolution uniformity and sensitivity of the NIH ATLAS small animal PET scanner: Comparison to simulated LSO scanners without depth-of-interaction capability
    Seidel, Y
    Vaquero, JJ
    Green, MV
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1555 - 1558
  • [35] Resolution uniformity and sensitivity of the NIH ATLAS small animal PET scanner: Comparison to simulated LSO scanners without depth-of-interaction capability
    Seidel, J
    Vaquero, JJ
    Green, MV
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (05) : 1347 - 1350
  • [36] Improved image generation for high resolution animal PET using Monte-Carlo simulations of the system response function.
    Boening, G
    Pichler, BJ
    Rafecas, M
    Schwaiger, M
    Lorenz, E
    Ziegler, SI
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 196P - 196P
  • [37] A 3-D Monte Carlo simulation of a small animal Positron Emission Tomograph with millimeter spatial resolution
    Bevilacqua, A
    Bollini, D
    Del Guerra, A
    Di Domenico, G
    Galli, M
    Scandola, M
    Zavattini, G
    1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 1702 - 1705
  • [38] A 3-D Monte Carlo simulation of a small animal Positron Emission Tomograph with millimeter spatial resolution
    Bevilacqua, A
    Bollini, D
    Del Guerra, A
    Di Domenico, G
    Galli, M
    Scandola, M
    Zavattini, G
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (03) : 697 - 701
  • [39] Assessment of the spatial resolution of PET scanners using a Geant4-based Monte Carlo tool
    Fiedler, K
    Frach, T
    Rütten, W
    Solf, T
    Thon, A
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2549 - 2553
  • [40] DYNAMIC DISPLAY OF MONTE-CARLO SIMULATION USING HIGH-RESOLUTION GRAPHICS
    NASSERSHARIF, B
    ROBINSON, AH
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1982, 41 : 43 - 43