Long-term performance of screw-in atrial pacing leads: A Randomized comparison of J-shaped and straight leads

被引:12
|
作者
Luria, D [1 ]
Bar-Lev, D
Gurevitz, S
Granit, H
Rotstein, Z
Eldar, M
Glikson, M
机构
[1] Chaim Sheba Med Ctr, Inst Heart, Cardiac Pacing & Electrophysiol Unit, IL-52621 Tel Hashomer, Israel
[2] Tel Aviv Univ, Sackler Fac Med, IL-69978 Tel Aviv, Israel
来源
关键词
atrial pacing; J-shaped; straight shaped leads;
D O I
10.1111/j.1540-8159.2005.00204.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Long-Term Performance of Screw-In Atrial Pacing Leads: A Randomized Comparison of J-Shaped and Straight Leads.Objective: In this prospective, randomized, control study we compared performance of J-shaped (JL) and straight atrial leads (SL) with active (screw-in)fixation mechanism, over a 5-year follow-up period. Subjects and Methods: A total of 208 consecutive patients were randomized for implantation with a Medtronic 4568 JL model (n = 103) versus a Medtronic 4068 SL model (n = 105), and all lead-related measurements and complications were recorded. Results: Lead-related complications occurred in JL and SL with similar frequency (6% and 9%, respectively, P = 0.45). Lead dislodgment occurred in 8 (7.8%) cases in SL versus none in JL (P = 0.004). Lead malfunction and excessive pacing thresholds without macrodislodgment occurred more frequently in JL (11; 10.7%) than in SL (4; 3.8%), P = 0.055. Lead material failure (insulation break) occurred only once in SL at the 5-year checkup. Most complications occurred during the first year after implantation. Other events occurred in both leads with similar frequency and included: death in 39 and 35, loss of follow-up in 8 and 6, and development of atrial fibrillation in 9 and 15 patients, respectively. Of those who completed follow-up, lead impedance and pacing threshold increased significantly in both groups. P wave decreased in SL but not in JL. Conclusion: More dislocations occurred in SL, but were counterbalanced by more lead malfunctions and excessive pacing thresholds in the JL group. Both leads demonstrated minor deterioration in electrical measurements during follow-up, with only 1 case of lead material failure in SL. Overall, both groups demonstrated favorable lead performance throughout follow-up.
引用
收藏
页码:898 / 902
页数:5
相关论文
共 50 条
  • [1] Randomized comparison of J-shaped and straight atrial screw-in pacing leads
    Glikson, M
    Yaacoby, E
    Feldman, S
    Bar-Lev, DS
    Yaroslavtzev, S
    Granit, C
    Rotstein, Z
    Kaplinsky, E
    Eldar, M
    MAYO CLINIC PROCEEDINGS, 2000, 75 (12) : 1269 - 1273
  • [2] Straight Screw-In Atrial Leads "J-Post Shaped" in Right Appendage Versus J-Shaped Systems for Permanent Atrial Pacing: A Safety Comparison
    Zoppo, Franco
    Zerbo, Francesca
    Brandolino, Glauco
    Bacchiega, Enrico
    Lupo, Antonio
    Bertaglia, Emanuele
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2011, 34 (03): : 325 - 330
  • [3] J-shaped versus straight leads for atrial implantation: Comparison of efficacy and safety
    Krupienicz, A
    Karczmarewicz, S
    Kulakowski, P
    Kozak, M
    Jacewicz, K
    Kociszewska, J
    Ceremuzynski, L
    Adamus, J
    EUROPACE '97 - THE OFFICIAL MEETING OF THE WORKING GROUPS ON CARDIAC PACING AND ARRHYTHMIAS OF THE EUROPEAN SOCIETY OF CARDIOLOGY, 1997, : 727 - 730
  • [4] RELIABILITY OF SCREW-IN LEADS FOR PERMANENT ATRIAL SENSING AND PACING
    SANTINI, M
    PANDOLFO, L
    ADINOLFI, E
    ALLIEGRO, A
    MASINI, V
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1981, 4 (03): : A93 - A93
  • [5] IMPROVED ATRIAL-PACING AND SENSING WITH SCREW-IN LEADS
    HAYES, D
    TRUSTY, J
    HOLMES, D
    HELLAND, J
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1985, 8 (05): : 778 - 778
  • [6] Randomized comparison of J-shaped atrial leads with and without active fixation mechanism
    Luria, David M.
    Feinberg, Micha S.
    Gurevitz, Osnat T.
    Bar-Lev, David S.
    Granit, Chava
    Tanami, Nechemia
    Eldar, Michael
    Glikson, Michael
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2007, 30 (03): : 412 - 417
  • [7] Effective long-term left atrial pacing using regular screw-in leads implanted within the coronary sinus
    Ouali, S
    Anselme, F
    Hidden, F
    Savouré, A
    Cribier, A
    Saoudi, N
    Frank, R
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2003, 26 (09): : 1873 - 1877
  • [8] LONG-TERM PERFORMANCE OF EPIMYOCARDIAL PACING LEADS IN ADULTS - COMPARISON WITH ENDOCARDIAL LEADS
    HELGUERA, ME
    MALONEY, JD
    WOSCOBOINIK, JR
    TROHMAN, RG
    MCCARTHY, PM
    MORANT, VA
    WILKOFF, BL
    CASTLE, LW
    PINSKI, SL
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1993, 16 (03): : 412 - 417
  • [9] Acute performance of steroid-eluting screw-in leads for atrial free wall pacing
    Nakazato, Y
    Nakata, Y
    Mineta, Y
    Nakazato, K
    Yasuda, M
    Sumiyoshi, M
    Yamaguchi, H
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1999, 63 (07): : 514 - 516
  • [10] Passive-fixation J-shaped versus straight leads in atrial position: Comparison of efficacy and safety
    Krupienicz, A
    Karczmarewicz, S
    Marciniak, W
    Gnilka, A
    Kulakowski, P
    Adamus, J
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2000, 23 (12): : 2068 - 2072