J-shaped versus straight leads for atrial implantation: Comparison of efficacy and safety

被引:0
|
作者
Krupienicz, A
Karczmarewicz, S
Kulakowski, P
Kozak, M
Jacewicz, K
Kociszewska, J
Ceremuzynski, L
Adamus, J
机构
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Although J-shaped electrode leads have been advocated for atrial implantation, their superiority over standard straight leads has not been well documented. Moreover, J-shaped leads are more expensive than straight leads. To compare the efficacy and safety of both types of leads we analysed retrospectively the results of 81 consecutive implantations of atrial Leads. One straight and three J-leads were replaced during the initial procedure by active fixation leads; as such, final study group consisted of 77 cases (61 DDD, 16 AAI): 58 were J and 19 straight leads. Stimulation threshold, slew late, impedance, P wave amplitude and procedure time did not differ significantly between two types of leads used. During follow-up of 8 - 45 months(25,4 +/- 10,1) 2 repositions of both lead types were required (difference not important statistically). In conclusion, J-shaped leads seem not to be superior to the straight leads for atrial implantations.
引用
收藏
页码:727 / 730
页数:4
相关论文
共 50 条
  • [1] Passive-fixation J-shaped versus straight leads in atrial position: Comparison of efficacy and safety
    Krupienicz, A
    Karczmarewicz, S
    Marciniak, W
    Gnilka, A
    Kulakowski, P
    Adamus, J
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2000, 23 (12): : 2068 - 2072
  • [2] Straight Screw-In Atrial Leads "J-Post Shaped" in Right Appendage Versus J-Shaped Systems for Permanent Atrial Pacing: A Safety Comparison
    Zoppo, Franco
    Zerbo, Francesca
    Brandolino, Glauco
    Bacchiega, Enrico
    Lupo, Antonio
    Bertaglia, Emanuele
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2011, 34 (03): : 325 - 330
  • [3] Randomized comparison of J-shaped and straight atrial screw-in pacing leads
    Glikson, M
    Yaacoby, E
    Feldman, S
    Bar-Lev, DS
    Yaroslavtzev, S
    Granit, C
    Rotstein, Z
    Kaplinsky, E
    Eldar, M
    MAYO CLINIC PROCEEDINGS, 2000, 75 (12) : 1269 - 1273
  • [4] Long-term performance of screw-in atrial pacing leads: A Randomized comparison of J-shaped and straight leads
    Luria, D
    Bar-Lev, D
    Gurevitz, S
    Granit, H
    Rotstein, Z
    Eldar, M
    Glikson, M
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2005, 28 (09): : 898 - 902
  • [5] Randomized comparison of J-shaped atrial leads with and without active fixation mechanism
    Luria, David M.
    Feinberg, Micha S.
    Gurevitz, Osnat T.
    Bar-Lev, David S.
    Granit, Chava
    Tanami, Nechemia
    Eldar, Michael
    Glikson, Michael
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2007, 30 (03): : 412 - 417
  • [6] Extraction of an accufix atrial J-shaped support wire
    Jessurun, C
    Sung, C
    Massumi, A
    CIRCULATION, 1997, 95 (11) : 2587 - 2587
  • [7] LONG-TERM FOLLOW-UP OF TRANSVENOUS ATRIAL PACEMAKER WITH J-SHAPED LEADS IN SICK SINUS SYNDROME
    KODAMA, K
    NANTO, S
    SUGII, M
    TANIURA, K
    YAMAGISHI, M
    KUNUZA, T
    MISHIMA, M
    INOUE, M
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1979, 2 (05): : A46 - A46
  • [8] INITIAL EXPERIENCE WITH A NEW TEMPORARY ATRIAL J-SHAPED PACING LEAD
    AZULAY, A
    BINDER, A
    WERRES, R
    PARSONNET, V
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1981, 4 (03): : A31 - A31
  • [9] PERMANENT PERVENOUS ATRIAL SENSING AND PACING WITH A NEW J-SHAPED LEAD
    SMYTH, NPD
    CITRON, P
    KESHISHIAN, JM
    GARCIA, JM
    KELLY, LC
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1976, 72 (04): : 565 - 570
  • [10] RETROGRADE CATHETERIZATION OF TORTUOUS ILIAC ARTERIES USING STRAIGHT AND J-SHAPED GUIDE WIRES
    SURAMO, I