Although J-shaped electrode leads have been advocated for atrial implantation, their superiority over standard straight leads has not been well documented. Moreover, J-shaped leads are more expensive than straight leads. To compare the efficacy and safety of both types of leads we analysed retrospectively the results of 81 consecutive implantations of atrial Leads. One straight and three J-leads were replaced during the initial procedure by active fixation leads; as such, final study group consisted of 77 cases (61 DDD, 16 AAI): 58 were J and 19 straight leads. Stimulation threshold, slew late, impedance, P wave amplitude and procedure time did not differ significantly between two types of leads used. During follow-up of 8 - 45 months(25,4 +/- 10,1) 2 repositions of both lead types were required (difference not important statistically). In conclusion, J-shaped leads seem not to be superior to the straight leads for atrial implantations.
引用
收藏
页码:727 / 730
页数:4
相关论文
共 50 条
  • [11] Comparison of J-Shaped Incision and Mercedes Incision for Liver Transplantation
    Wiederkehr, Julio C.
    Igreja, Mauro R.
    Goncalves, Nelson
    Nogara, Marcelo S.
    Sequinel, Amanda P.
    Sampaio, Ana L.
    Montemezzo, Gabrielle P.
    Wiederkehr, Henrique A.
    Wassen, Matheus P.
    LIVER TRANSPLANTATION, 2014, 20 : S369 - S369
  • [12] COMPARISON OF THE MYOELECTRICAL ACTIVITY OF THE LATERAL AND J-SHAPED ILEAL RESERVOIRS
    STONE, MM
    MULVIHILL, SJ
    SNAPE, WJ
    FONKALSRUD, EW
    JOURNAL OF PEDIATRIC SURGERY, 1986, 21 (06) : 500 - 505
  • [13] Intrapulmonary artery and intrabronchial migration and extraction of a fragment of J-shaped atrial pacing catheter
    Tatou, E
    Lefez, C
    Reybet-Degat, O
    Wolf, JE
    Louis, P
    Favre, JP
    David, M
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1999, 22 (12): : 1829 - 1830
  • [14] Spiral versus J-shaped coils for neurovascular embolisation -: an in-vitro study
    Sugiu, K
    Tokunaga, K
    Mandai, S
    Martin, JB
    Jean, B
    Rüfenacht, DA
    NEURORADIOLOGY, 2003, 45 (07) : 417 - 422
  • [15] Spiral versus J-shaped coils for neurovascular embolisation—an in-vitro study
    K. Sugiu
    K. Tokunaga
    S. Mandai
    J. B. Martin
    B. Jean
    D. A. Rüfenacht
    Neuroradiology, 2003, 45 : 417 - 422
  • [16] Malfunction of an active fixation J-shaped screw-in atrial electrode lead: A case report
    Lee, WL
    Kong, CW
    Lin, MR
    Wang, JJ
    Chan, WL
    Wang, SP
    Chang, MS
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (08): : 2026 - 2028
  • [17] LONGTERM FOLLOW-UP OF J-SHAPED TINED PERMANENT ATRIAL-PACING LEAD
    WALLNER, H
    PRABHU, R
    BROWN, C
    CHEST, 1981, 80 (03) : 346 - 346
  • [18] J-shaped versus median sternotomy for aortic valve replacement with minimal extracorporeal circuit
    Yilmaz, Alaaddin
    Sjatskig, Jelena
    van Boven, Wim J.
    Waanders, Frans G.
    Kelder, Johannes C.
    Sonker, Uday
    Kloppenburg, Geoffrey T. L.
    SCANDINAVIAN CARDIOVASCULAR JOURNAL, 2011, 45 (06) : 379 - 384
  • [19] Numerical study of airfoil thickness effects on the performance of J-shaped straight blade vertical axis wind turbine
    Zamani, Mahdi
    Maghrebi, Mohammad Javad
    Moshizi, Sajad A.
    WIND AND STRUCTURES, 2016, 22 (05) : 595 - 616
  • [20] EFFECT OF BODY MASS INDEX ON MORTALITY AFTER TRANSCATHETER AORTIC VALVE IMPLANTATION: J-SHAPED CURVE
    Gonzalez Ferreiro, Roco
    Lopez Otero, Diego
    Munoz-Garcia, Antonio J.
    Avanzas, Pablo
    Pascual, Isaac
    Alonso Briales, Juan H.
    Trillo Nouche, Ramiro
    Pun Chinchay, Federico
    Jimenez Navarro, Manuel
    Hernandez Garcia, Jose Maria
    Moris, Cesar
    Gonzalez Juanatey, Jose Ramon
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 69 (11) : 1229 - 1229