Long-term performance of screw-in atrial pacing leads: A Randomized comparison of J-shaped and straight leads

被引:12
|
作者
Luria, D [1 ]
Bar-Lev, D
Gurevitz, S
Granit, H
Rotstein, Z
Eldar, M
Glikson, M
机构
[1] Chaim Sheba Med Ctr, Inst Heart, Cardiac Pacing & Electrophysiol Unit, IL-52621 Tel Hashomer, Israel
[2] Tel Aviv Univ, Sackler Fac Med, IL-69978 Tel Aviv, Israel
来源
关键词
atrial pacing; J-shaped; straight shaped leads;
D O I
10.1111/j.1540-8159.2005.00204.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Long-Term Performance of Screw-In Atrial Pacing Leads: A Randomized Comparison of J-Shaped and Straight Leads.Objective: In this prospective, randomized, control study we compared performance of J-shaped (JL) and straight atrial leads (SL) with active (screw-in)fixation mechanism, over a 5-year follow-up period. Subjects and Methods: A total of 208 consecutive patients were randomized for implantation with a Medtronic 4568 JL model (n = 103) versus a Medtronic 4068 SL model (n = 105), and all lead-related measurements and complications were recorded. Results: Lead-related complications occurred in JL and SL with similar frequency (6% and 9%, respectively, P = 0.45). Lead dislodgment occurred in 8 (7.8%) cases in SL versus none in JL (P = 0.004). Lead malfunction and excessive pacing thresholds without macrodislodgment occurred more frequently in JL (11; 10.7%) than in SL (4; 3.8%), P = 0.055. Lead material failure (insulation break) occurred only once in SL at the 5-year checkup. Most complications occurred during the first year after implantation. Other events occurred in both leads with similar frequency and included: death in 39 and 35, loss of follow-up in 8 and 6, and development of atrial fibrillation in 9 and 15 patients, respectively. Of those who completed follow-up, lead impedance and pacing threshold increased significantly in both groups. P wave decreased in SL but not in JL. Conclusion: More dislocations occurred in SL, but were counterbalanced by more lead malfunctions and excessive pacing thresholds in the JL group. Both leads demonstrated minor deterioration in electrical measurements during follow-up, with only 1 case of lead material failure in SL. Overall, both groups demonstrated favorable lead performance throughout follow-up.
引用
收藏
页码:898 / 902
页数:5
相关论文
共 50 条
  • [31] Alternative to the transvenous approach in pediatric pacing - Long-term experiences with bipolar epicardial pacing leads
    Bauersfeld U.
    Przibille O.
    Gajic Z.
    Fåhraeus T.
    Kampmann C.
    Rahn-Schönbeck M.
    Schüller H.
    Herzschrittmachertherapie + Elektrophysiologie, 2001, 12 (3) : 158 - 162
  • [32] Long-term comparison of coronary venous leads versus epicardial leads for left-ventricular pacing in patients receiving cardiac resynchronization therapy
    Koos, R
    Sinha, AM
    Markus, KU
    Breithardt, OA
    Mischke, K
    Zarse, M
    Greiser, M
    Stellbrink, C
    EUROPEAN HEART JOURNAL, 2003, 24 : 398 - 398
  • [33] Postmortem analysis of encapsulation around long-term ventricular endocardial pacing leads
    Candinas, R
    Duru, F
    Schneider, J
    Lüscher, TF
    Stokes, K
    MAYO CLINIC PROCEEDINGS, 1999, 74 (02) : 120 - 125
  • [34] Long-term performance of right ventricular pacing leads: risk factors associated with permanent right ventricular pacing threshold increase
    Hui Peng
    Zhijun Sun
    Heping Zhang
    Wenying Ma
    Journal of Interventional Cardiac Electrophysiology, 2019, 55 : 349 - 357
  • [35] Long-term performance of right ventricular pacing leads: risk factors associated with permanent right ventricular pacing threshold increase
    Peng, Hui
    Sun, Zhijun
    Zhang, Heping
    Ma, Wenying
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2019, 55 (03) : 349 - 357
  • [36] LONG-TERM FOLLOW-UP OF TRANSVENOUS ENDOCARDIAL ATRIAL LEADS
    KRUSE, IM
    RYDEN, L
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1987, 10 (03): : 702 - 702
  • [37] Active-fixation Atrial Pacing Leads Following Amputation of Right Atrial Appendage: Long-term, Single-centre Study
    Huang, Dong
    Zhang, Qingyong
    Pan, Yesheng
    Liu, Mingya
    Wei, Meng
    Li, Jingbo
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (16) : C176 - C176
  • [38] Long-term experience with subcutaneous ICD leads: A comparison between three different types of subcutaneous leads
    Kettering, K
    Mewis, C
    Doernberger, V
    Vonthein, R
    Kuehlkamp, V
    CIRCULATION, 2003, 108 (17) : 545 - 545
  • [39] Long-term experience with subcutaneous ICD leads:: A comparison among three different types of subcutaneous leads
    Kettering, K
    Mewis, C
    Dörnberger, V
    Vonthein, R
    Bosch, RF
    Seipel, L
    Kühlkamp, V
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2004, 27 (10): : 1355 - 1361
  • [40] Long-term thresholds of nonsteroidal permanent pacing leads: A 5-year study
    Gumbrielle, TP
    Bourke, JP
    Sinkovic, M
    Tynan, M
    Kittpawong, P
    Gold, RG
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (05): : 829 - 835