Comparative Study of Cardiac Output Measurement by Regional Impedance Cardiography and Thermodilution Method in Patients Undergoing off Pump Coronary Artery Bypass Graft Surgery

被引:1
|
作者
Guha, Amrita [1 ]
Arora, Dheeraj [1 ]
Mehta, Yatin [1 ]
机构
[1] Medanta Medicity, Dept Cardiac Anaesthesiol, Gurugram, Haryana, India
关键词
Noninvasive cardiac output monitoring; off pump coronary artery bypass graft surgery; regional impedance cardiography; thermodilution; THORACIC ELECTRICAL BIOIMPEDANCE;
D O I
10.4103/aca.aca_44_21
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: An ideal CO monitor should be noninvasive, cost effective, reproducible, reliable during various physiological states. Limited literature is available regarding the noninvasive CO monitoring in open chest surgeries. Aim: The aim of this study was to compare the CO measurement by Regional Impedance Cardiography (RIC) and Thermodilution (TD) method in patients undergoing off pump coronary artery bypass graft surgery (OPCAB). Settings and Design: We conducted a prospective observational comparative study of CO measurement by the noninvasive RIC method using the NICaS Hemodynamic Navigator system and the gold standard TD method using pulmonary artery catheter in patients undergoing OPCAB. A total of 150 data pair from the two CO monitoring techniques were taken from 15 patients between 40-70 years at various predefined time intervals of the surgery. Patients and Methods: We have tried to find out the accuracy, precision and cost effectiveness of the newer RIC technique. Mean CO, bias and precision were compared for each pair i.e.TD-CO and RIC-CO as recommended by Bland and Altman. The Sensitivity and specificity of cutoff value to predict change in TD-CO was used to create a Receiver operating characteristic or ROC curve. Results: Mean TD-CO values were around 4.52 +/- 1.09 L/min, while mean RIC- CO values were around 4.77 +/- 1.84 L/min. The difference in CO change was found to be statistically not significant (p value 0.667). The bias was small (-0.25). The Bland Altman plot revealed a mean difference of -0.25 litres. The RIC method had a sensitivity of 55.56 % and specificity of 33.33 % in predicting 15% change in CO of TD method and the total diagnostic accuracy was 46.67%. Conclusion: A fair correlation was found between the two techniques. The RIC method may be considered as a promising noninvasive, potentially low cost alternative to the TD technique of hemodynamic measurement.
引用
收藏
页码:335 / 342
页数:8
相关论文
共 50 条
  • [41] Graft Patency After Off-Pump Coronary Artery Bypass Surgery
    Thourani, Vinod H.
    Guyton, Robert A.
    CIRCULATION, 2012, 125 (23) : 2806 - 2808
  • [42] Spectral Entropy Monitoring Reduces Anesthetic Dosage for Patients Undergoing Off-Pump Coronary Artery Bypass Graft Surgery
    Ma Jiahai
    Wang Xueyan
    Xie Yonggang
    Yu Jianhong
    He Qunhui
    Li Zhi
    Du Juan
    Jiang Xiuliang
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2012, 26 (05) : 818 - 821
  • [43] Effects of ulinastatin on coagulation in high-risk patients undergoing off-pump coronary artery bypass graft surgery
    Kim, Na-Young
    Shim, Jae-Kwang
    Bang, Seo-Ouk
    Sim, Jee-Suk
    Song, Jong-Wook
    Kwak, Young-Lan
    KOREAN JOURNAL OF ANESTHESIOLOGY, 2013, 64 (02) : 105 - 111
  • [44] The effect of remote ischaemic preconditioning on myocardial injury in patients undergoing off-pump coronary artery bypass graft surgery
    Hong, D. M.
    Min, J. J.
    Kim, J. H.
    Sohn, I. S.
    Lim, T. W.
    Lim, Y. J.
    Bahk, J. -H.
    Jeon, Y.
    ANAESTHESIA AND INTENSIVE CARE, 2010, 38 (05) : 924 - 929
  • [45] The effects of intracoronary nicardipine on ventricular dynamics and function in patients undergoing off-pump coronary artery bypass graft surgery
    Casthely, Pierre Abdon
    Defilippi, Vincent
    Pakonis, Gregory
    Bikkina, Mahesh
    Yoganathan, Thil
    Komer, Claudia
    Cornwell, Lorraine
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2008, 22 (02) : 192 - 198
  • [46] Efficacy of fenoldopam in preserving renal function in patients undergoing off-pump coronary artery bypass graft (CABG) surgery
    Hayman, M
    Hofmaster, PA
    Hernandez, F
    CRITICAL CARE MEDICINE, 2003, 31 (12) : A52 - A52
  • [47] Haemodynamic effects of a milrinone infusion without a bolus in patients undergoing off-pump coronary artery bypass graft surgery
    Kwak, YL
    Oh, YJ
    Shinn, HK
    Yoo, KJ
    Kim, SH
    Hong, YW
    ANAESTHESIA, 2004, 59 (04) : 324 - 331
  • [48] Correlation of Akinesia With Graft Patency and Cardiac Enzyme After Off-Pump Coronary Artery Bypass Graft Surgery
    Yang, Hongseok
    Youn, Young-Nam
    Yoo, Kyung Jong
    CIRCULATION JOURNAL, 2010, 74 (08) : 1564 - 1569
  • [49] Emergency Off-Pump Coronary Artery Bypass Graft Surgery for Patients on Preoperative Intraaortic Balloon Pump
    Ito, Hisato
    Mizumoto, Toru
    Tempaku, Hironori
    Fujinaga, Kazuya
    Sawada, Yasuhiro
    Teranishi, Satoshi
    Shimpo, Hideto
    ANNALS OF THORACIC SURGERY, 2016, 102 (03): : 821 - 828
  • [50] Comparative study of on-pump and off-pump coronary bypass surgery in patients with triple-vessel coronary artery disease
    陈鑫
    徐明
    史宏伟
    穆心伟
    陈振强
    邱志兵
    中华医学杂志(英文版), 2004, (03) : 23 - 27