Comparative Study of Cardiac Output Measurement by Regional Impedance Cardiography and Thermodilution Method in Patients Undergoing off Pump Coronary Artery Bypass Graft Surgery

被引:1
|
作者
Guha, Amrita [1 ]
Arora, Dheeraj [1 ]
Mehta, Yatin [1 ]
机构
[1] Medanta Medicity, Dept Cardiac Anaesthesiol, Gurugram, Haryana, India
关键词
Noninvasive cardiac output monitoring; off pump coronary artery bypass graft surgery; regional impedance cardiography; thermodilution; THORACIC ELECTRICAL BIOIMPEDANCE;
D O I
10.4103/aca.aca_44_21
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: An ideal CO monitor should be noninvasive, cost effective, reproducible, reliable during various physiological states. Limited literature is available regarding the noninvasive CO monitoring in open chest surgeries. Aim: The aim of this study was to compare the CO measurement by Regional Impedance Cardiography (RIC) and Thermodilution (TD) method in patients undergoing off pump coronary artery bypass graft surgery (OPCAB). Settings and Design: We conducted a prospective observational comparative study of CO measurement by the noninvasive RIC method using the NICaS Hemodynamic Navigator system and the gold standard TD method using pulmonary artery catheter in patients undergoing OPCAB. A total of 150 data pair from the two CO monitoring techniques were taken from 15 patients between 40-70 years at various predefined time intervals of the surgery. Patients and Methods: We have tried to find out the accuracy, precision and cost effectiveness of the newer RIC technique. Mean CO, bias and precision were compared for each pair i.e.TD-CO and RIC-CO as recommended by Bland and Altman. The Sensitivity and specificity of cutoff value to predict change in TD-CO was used to create a Receiver operating characteristic or ROC curve. Results: Mean TD-CO values were around 4.52 +/- 1.09 L/min, while mean RIC- CO values were around 4.77 +/- 1.84 L/min. The difference in CO change was found to be statistically not significant (p value 0.667). The bias was small (-0.25). The Bland Altman plot revealed a mean difference of -0.25 litres. The RIC method had a sensitivity of 55.56 % and specificity of 33.33 % in predicting 15% change in CO of TD method and the total diagnostic accuracy was 46.67%. Conclusion: A fair correlation was found between the two techniques. The RIC method may be considered as a promising noninvasive, potentially low cost alternative to the TD technique of hemodynamic measurement.
引用
收藏
页码:335 / 342
页数:8
相关论文
共 50 条
  • [31] Genome Wide Association Study For Acute Kidney Injury In Patients Undergoing Off-pump Coronary Artery Bypass Graft Surgery
    Kanchi, Muralidhar
    Menon, Ramesh
    Mishra, Sangamitra
    Vedam, Ramprasad
    CIRCULATION, 2021, 144
  • [32] Cardiac output estimation by pulse wave analysis using the pressure recording analytical method and intermittent pulmonary artery thermodilution A method comparison study after off-pump coronary artery bypass surgery
    Greiwe, Gillis
    Luehsen, Katharina
    Hapfelmeier, Alexander
    Rogge, Dorothea
    Kubik, Mathias
    Schulte-Uentrop, Leonie
    Saugel, Bernd
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2020, 37 (10) : 920 - 925
  • [33] Metabolomic profiling in patients undergoing Off-Pump or On-Pump coronary artery bypass surgery
    Kirov, H.
    Schwarzer, M.
    Neugebauer, S.
    Faerber, G.
    Diab, M.
    Doenst, T.
    BMC CARDIOVASCULAR DISORDERS, 2017, 17 : 1 - 8
  • [34] Metabolomic profiling in patients undergoing Off-Pump or On-Pump coronary artery bypass surgery
    H. Kirov
    M. Schwarzer
    S. Neugebauer
    G. Faerber
    M. Diab
    T. Doenst
    BMC Cardiovascular Disorders, 17
  • [35] Comparative study between on-pump and off-pump coronary artery bypass graft in women
    Barros de Oliveira Sa, Michel Pompeu
    Lima, Leonardo Pontual
    de Rueda, Fabio Goncalves
    de Escobar, Rodrigo Renda
    Ferraz Cavalcanti, Paulo Ernando
    da Silva The, Emmanuel Callou
    Soares de Escobar, Mozart Augusto
    Lima, Ricardo de Carvalho
    REVISTA BRASILEIRA DE CIRURGIA CARDIOVASCULAR, 2010, 25 (02): : 238 - 244
  • [36] Continuous cardiac output estimation using a new modified Fick method during off-pump coronary artery bypass graft surgery: a retrospective observational study
    Chahyun Oh
    Hyung-Chul Lee
    Soomin Lee
    Man-Shik Shim
    Soo Bin Yoon
    Jinsik Jung
    Seok-Hwa Yoon
    Yoon-Hee Kim
    Youngkwon Ko
    Boohwi Hong
    Yunseo Ku
    Journal of Anesthesia, 2024, 38 (1) : 1 - 9
  • [37] Continuous cardiac output estimation using a new modified Fick method during off-pump coronary artery bypass graft surgery: a retrospective observational study
    Oh, Chahyun
    Lee, Hyung-Chul
    Lee, Soomin
    Shim, Man-Shik
    Yoon, Soo Bin
    Jung, Jinsik
    Yoon, Seok-Hwa
    Kim, Yoon-Hee
    Ko, Youngkwon
    Hong, Boohwi
    Ku, Yunseo
    JOURNAL OF ANESTHESIA, 2024, 38 (01) : 1 - 9
  • [38] CARDIAC REHABILITATION IN PATIENTS UNDERGOING TO CORONARY ARTERY BYPASS GRAFT
    Aikawa, Priscila
    Sartori Cintra, Angelica Rossi
    de Oliveíra Junior, Abelardo Soares
    Mackmillan da Silva, Claudio Tafarel
    Pierucci, Juliana Dale
    Afonso, Max dos Santos
    Souza, Maicon de Pinho
    Paulitsch, Felipe da Silva
    REVISTA BRASILEIRA DE MEDICINA DO ESPORTE, 2014, 20 (01) : 55 - 58
  • [39] Pharmacological Preconditioning with Intralipid in Patients Undergoing Off-Pump Coronary Artery Bypass Surgery
    Pruthi, Gegal
    Singh, Naveen G.
    Nagaraja, P. S.
    Balaji, Rohini Mayur
    Manjunatha, N.
    Choudhary, P. K.
    Raja, M. Kurinchi
    ANNALS OF CARDIAC ANAESTHESIA, 2020, 23 (03) : 327 - 331
  • [40] Metabolic changes and clinical outcomes in patients undergoing on and off pump coronary artery bypass surgery
    Warang M.
    Waradkar A.
    Patwardhan A.
    Agrawal N.
    Kane D.
    Parulkar G.
    Khandeparkar J.
    Indian Journal of Thoracic and Cardiovascular Surgery, 2007, 23 (1) : 9 - 15