Comparative Study of Cardiac Output Measurement by Regional Impedance Cardiography and Thermodilution Method in Patients Undergoing off Pump Coronary Artery Bypass Graft Surgery

被引:1
|
作者
Guha, Amrita [1 ]
Arora, Dheeraj [1 ]
Mehta, Yatin [1 ]
机构
[1] Medanta Medicity, Dept Cardiac Anaesthesiol, Gurugram, Haryana, India
关键词
Noninvasive cardiac output monitoring; off pump coronary artery bypass graft surgery; regional impedance cardiography; thermodilution; THORACIC ELECTRICAL BIOIMPEDANCE;
D O I
10.4103/aca.aca_44_21
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: An ideal CO monitor should be noninvasive, cost effective, reproducible, reliable during various physiological states. Limited literature is available regarding the noninvasive CO monitoring in open chest surgeries. Aim: The aim of this study was to compare the CO measurement by Regional Impedance Cardiography (RIC) and Thermodilution (TD) method in patients undergoing off pump coronary artery bypass graft surgery (OPCAB). Settings and Design: We conducted a prospective observational comparative study of CO measurement by the noninvasive RIC method using the NICaS Hemodynamic Navigator system and the gold standard TD method using pulmonary artery catheter in patients undergoing OPCAB. A total of 150 data pair from the two CO monitoring techniques were taken from 15 patients between 40-70 years at various predefined time intervals of the surgery. Patients and Methods: We have tried to find out the accuracy, precision and cost effectiveness of the newer RIC technique. Mean CO, bias and precision were compared for each pair i.e.TD-CO and RIC-CO as recommended by Bland and Altman. The Sensitivity and specificity of cutoff value to predict change in TD-CO was used to create a Receiver operating characteristic or ROC curve. Results: Mean TD-CO values were around 4.52 +/- 1.09 L/min, while mean RIC- CO values were around 4.77 +/- 1.84 L/min. The difference in CO change was found to be statistically not significant (p value 0.667). The bias was small (-0.25). The Bland Altman plot revealed a mean difference of -0.25 litres. The RIC method had a sensitivity of 55.56 % and specificity of 33.33 % in predicting 15% change in CO of TD method and the total diagnostic accuracy was 46.67%. Conclusion: A fair correlation was found between the two techniques. The RIC method may be considered as a promising noninvasive, potentially low cost alternative to the TD technique of hemodynamic measurement.
引用
收藏
页码:335 / 342
页数:8
相关论文
共 50 条
  • [1] A Retrospective Study of Hemodynamic Changes in Patients After Off-Pump Coronary Artery Bypass Graft Surgery Using Impedance Cardiography
    Niu, Xinrong
    Zhang, Qingqing
    Xiao, Dong
    Zhang, Yuanming
    MEDICAL SCIENCE MONITOR, 2019, 25 : 3454 - 3462
  • [2] Cardiac output measurement after coronary artery bypass grafting using bolus thermodilution, continuous thermodilution, and whole-body impedance cardiography
    Kaukinen, S
    Kööbi, T
    Bi, YB
    Turjanmaa, VMH
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2003, 17 (02) : 199 - 203
  • [3] Correlation of cardiac output measured by non-invasive continuous cardiac output monitoring (NICOM) and thermodilution in patients undergoing off-pump coronary artery bypass surgery
    Hoiyin Cheung
    Quan Dong
    Rong Dong
    Buwei Yu
    Journal of Anesthesia, 2015, 29 : 416 - 420
  • [4] Correlation of cardiac output measured by non-invasive continuous cardiac output monitoring (NICOM) and thermodilution in patients undergoing off-pump coronary artery bypass surgery
    Cheung, Hoiyin
    Dong, Quan
    Dong, Rong
    Yu, Buwei
    JOURNAL OF ANESTHESIA, 2015, 29 (03) : 416 - 420
  • [5] Comparison of transthoracic electrical bioimpedance cardiac output measurement with thermodilution method in post coronary artery bypass graft patients
    Sharma, Vikas
    Singh, Ajmer
    Kansara, Bhuvnesh
    Karlekar, Anil
    ANNALS OF CARDIAC ANAESTHESIA, 2011, 14 (02) : 104 - 110
  • [6] THE ACCURACY OF IMPEDANCE CARDIOGRAPHY IN MEASUREMENT OF CARDIAC-OUTPUT IN COMPARISON WITH THERMODILUTION METHOD
    WONG, KL
    BRITISH JOURNAL OF ANAESTHESIA, 1994, 72 : 16 - 16
  • [7] Comparison of Uncalibrated Arterial Pressure Waveform Analysis with Continuous Thermodilution Cardiac Output Measurements in Patients Undergoing Elective Off-Pump Coronary Artery Bypass Surgery
    Jeong, Yong Bo
    Kim, Tae Hee
    Roh, Young Jin
    Choi, In Cheol
    Suh, Jeong Hun
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2010, 24 (05) : 767 - 771
  • [8] A comparison of CardioQ and thermodilution cardiac output during off-pump coronary artery surgery
    Hullett, B
    Gibbs, N
    Weightman, W
    Thackray, M
    Newman, M
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2003, 17 (06) : 728 - 732
  • [9] Cardiac output monitoring: Comparison of a new arterial pressure waveform analysis to the bolus thermodilution technique in patients undergoing off-pump coronary artery bypass surgery
    Mehta, Yatin
    Chand, Rajesh Kumar
    Sawhney, Ravindra
    Bhise, Milind
    Singh, Ajmer
    Trehan, Naresh
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2008, 22 (03) : 394 - 399
  • [10] Clinical profiles of patients undergoing off-pump coronary artery bypass graft surgery: The california coronary artery bypass graft surgery outcomes reporting program
    Li, Zhongmin
    Yeo, Khung-Keong
    Mahendra, Geeta
    Amsterdam, Ezra A.
    CIRCULATION, 2007, 116 (16) : 643 - 643