Evaluation of dual-energy and perfusion CT parameters for diagnosing solitary pulmonary nodules

被引:19
|
作者
Zhu, Beilin [1 ]
Zheng, Shuo [1 ]
Jiang, Tao [1 ]
Hu, Bin [1 ]
机构
[1] Capital Med Univ, Beijing Chaoyang Hosp, Beijing, Peoples R China
关键词
dual-energy; perfusion; radiation dosage; solitary pulmonary nodules; COMPUTED-TOMOGRAPHY; LUNG-CANCER; TUMOR ANGIOGENESIS; ENHANCEMENT;
D O I
10.1111/1759-7714.14105
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background To evaluate the correlation and accuracy of dual-energy CT (DECT) (70/Sn150) and low-dose volume perfusion CT (VPCT) parameters for the diagnosis of solitary pulmonary nodules (SPN). Methods A total of 15 patients with benign SPN (mean age 56 +/- 7 years) and 34 patients with malignant SPN and clinical indication for surgery (mean age 58 +/- 6 years) were enrolled from July 2017 to September 2019 at a single institution. All the patients underwent low-dose VPCT with a scan volume of 114 mm on the z-axis and a venous phase enhancement DECT (70/150 Sn) scan just before surgery on the same day. All CT findings were studied in comparison with the pathological results after surgery. Perfusion and dual-energy CT parameters such as blood flow (BF), blood volume (BV), mean transit time (MTT), flow extraction product (FED), pulmonary nodule enhancement peak (PPnod) and iodine concentration (IC) were evaluated as well as t-test, chi-square test, Pearson correlation analysis, and ROC curve analysis to determine the significance of study parameters. Results The effective radiation dosage of the VPCT and DECT scans were 4.67 +/- 0.26 mSv and 0.32 +/- 0.10 mSv, respectively. Significant correlations were found between iodine concentration from DECT and VPCT parameters (r = 0.376-0.533, p < 0.05). The sensitivity and specificity of IC to differentiate the SPN were 86.67% and 72.73%, which was slightly lower than that of BV (94.44%, 73.33%), FED (88.89%, 80.00%) and PPnod (94.44%, 80.00%). Conclusions VPCT scans have low radiation dosage achieved by shortening the z-axis scan range for assessment of SPN. IC from DECT is significantly correlated with VPCT parameters, and VPCT parameters have better diagnostic performance for SPN than DECT parameters.
引用
收藏
页码:2691 / 2697
页数:7
相关论文
共 50 条
  • [41] Dual Energy CT Evaluation of the Severity of Pulmonary Thromboembolism: Correlation of Pulmonary Perfusion Score with CT
    Bayraktaroglu, Selen
    Cinkooglu, Akin
    Savas, Recep
    Ceylan, Naim
    Bozdag, Mustafa
    Karakus, Haydar Soydaner
    Cok, Gursel
    IRANIAN JOURNAL OF RADIOLOGY, 2020, 17 (03) : 1 - 8
  • [42] Dual-energy Computed Tomography for the Evaluation of Enhancement of Pulmonary Nodules≤3 cm in Size
    Reiter, Michael J.
    Winkler, Weston T.
    Kagy, Kenton E.
    Schwope, Ryan B.
    Lisanti, Christopher J.
    JOURNAL OF THORACIC IMAGING, 2017, 32 (03) : 189 - 197
  • [43] Comparison of single- and dual-energy CT combined with artificial intelligence for the diagnosis of pulmonary nodules
    Zhu, X.
    Zhu, L.
    Song, D.
    Wang, D.
    Wu, F.
    Wu, J.
    CLINICAL RADIOLOGY, 2023, 78 (02) : e99 - e105
  • [44] CALCIFICATION IN PULMONARY NODULES - DETECTION WITH DUAL-ENERGY DIGITAL RADIOGRAPHY
    FRASER, RG
    HICKEY, NM
    NIKLASON, LT
    SABBAGH, EA
    LUNA, RF
    ALEXANDER, CB
    ROBINSON, CA
    KATZENSTEIN, ALA
    BARNES, GT
    RADIOLOGY, 1986, 160 (03) : 595 - 601
  • [45] Dual-Energy CT for Characterization of Adrenal Nodules: Initial Experience
    Gupta, Rajan T.
    Ho, Lisa M.
    Marin, Daniele
    Boll, Daniel T.
    Barnhart, Huiman X.
    Nelson, Rendon C.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (06) : 1479 - 1483
  • [46] CT reconstruction algorithm selection in the evaluation of solitary pulmonary nodules
    Mayo Clinic, 200 First Street Southwest, Rochester, MN 55905, United States
    J. COMPUT. ASSISTED TOMOGR., 6 (932-935):
  • [47] CT RECONSTRUCTION ALGORITHM SELECTION IN THE EVALUATION OF SOLITARY PULMONARY NODULES
    SWENSEN, SJ
    MORIN, RL
    AUGHENBAUGH, GL
    LEIMER, DW
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1995, 19 (06) : 932 - 935
  • [48] Evaluation of Lung Perfusion With Dual-Energy Computed Tomography in a Chronic Pulmonary Thromboembolism Patient
    Hong, Yoo Jin
    Kim, Young Jin
    Lee, Sak
    Choe, Kyu-Ok
    ANNALS OF THORACIC SURGERY, 2011, 91 (04): : E62 - E62
  • [49] The low attenuation area on dual-energy perfusion CT: Correlation with the pulmonary function tests and quantitative CT measurements
    Okada, Munemasa
    Kunihiro, Yoshie
    Nakashima, Yoshiteru
    Matsunaga, Naofumi
    Sano, Yuichi
    Yuasa, Yuuki
    Narazaki, Akiko
    Kudomi, Shohei
    Koike, Masahiro
    Kido, Shoji
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (10) : 2892 - 2899
  • [50] Value of Dual-energy Lung Perfusion Imaging Using a Dual-source CT System for the Pulmonary Embolism
    Zhang, Jinshan
    Cai, Jing
    Liu, Shulan
    Zhang, Xianmei
    OPEN LIFE SCIENCES, 2018, 13 (01): : 107 - 111