Evaluation of dual-energy and perfusion CT parameters for diagnosing solitary pulmonary nodules

被引:19
|
作者
Zhu, Beilin [1 ]
Zheng, Shuo [1 ]
Jiang, Tao [1 ]
Hu, Bin [1 ]
机构
[1] Capital Med Univ, Beijing Chaoyang Hosp, Beijing, Peoples R China
关键词
dual-energy; perfusion; radiation dosage; solitary pulmonary nodules; COMPUTED-TOMOGRAPHY; LUNG-CANCER; TUMOR ANGIOGENESIS; ENHANCEMENT;
D O I
10.1111/1759-7714.14105
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background To evaluate the correlation and accuracy of dual-energy CT (DECT) (70/Sn150) and low-dose volume perfusion CT (VPCT) parameters for the diagnosis of solitary pulmonary nodules (SPN). Methods A total of 15 patients with benign SPN (mean age 56 +/- 7 years) and 34 patients with malignant SPN and clinical indication for surgery (mean age 58 +/- 6 years) were enrolled from July 2017 to September 2019 at a single institution. All the patients underwent low-dose VPCT with a scan volume of 114 mm on the z-axis and a venous phase enhancement DECT (70/150 Sn) scan just before surgery on the same day. All CT findings were studied in comparison with the pathological results after surgery. Perfusion and dual-energy CT parameters such as blood flow (BF), blood volume (BV), mean transit time (MTT), flow extraction product (FED), pulmonary nodule enhancement peak (PPnod) and iodine concentration (IC) were evaluated as well as t-test, chi-square test, Pearson correlation analysis, and ROC curve analysis to determine the significance of study parameters. Results The effective radiation dosage of the VPCT and DECT scans were 4.67 +/- 0.26 mSv and 0.32 +/- 0.10 mSv, respectively. Significant correlations were found between iodine concentration from DECT and VPCT parameters (r = 0.376-0.533, p < 0.05). The sensitivity and specificity of IC to differentiate the SPN were 86.67% and 72.73%, which was slightly lower than that of BV (94.44%, 73.33%), FED (88.89%, 80.00%) and PPnod (94.44%, 80.00%). Conclusions VPCT scans have low radiation dosage achieved by shortening the z-axis scan range for assessment of SPN. IC from DECT is significantly correlated with VPCT parameters, and VPCT parameters have better diagnostic performance for SPN than DECT parameters.
引用
收藏
页码:2691 / 2697
页数:7
相关论文
共 50 条
  • [21] Quantitative lobar pulmonary perfusion assessment on dual-energy CT pulmonary angiography: applications in pulmonary embolism
    Ramandeep Singh
    Ryan Zipan Nie
    Fatemeh Homayounieh
    Bernhard Schmidt
    Thomas Flohr
    Mannudeep K. Kalra
    European Radiology, 2020, 30 : 2535 - 2542
  • [22] Differentiating pulmonary metastasis from benign lung nodules in thyroid cancer patients using dual-energy CT parameters
    Ha, Taeho
    Kim, Wooil
    Cha, Jaehyung
    Lee, Young Hen
    Seo, Hyung Suk
    Park, So Young
    Kim, Nan Hee
    Hwang, Sung Ho
    Yong, Hwan Seok
    Oh, Yu-Whan
    Kang, Eun-Young
    Kim, Cherry
    EUROPEAN RADIOLOGY, 2022, 32 (03) : 1902 - 1911
  • [23] Differentiating pulmonary metastasis from benign lung nodules in thyroid cancer patients using dual-energy CT parameters
    Taeho Ha
    Wooil Kim
    Jaehyung Cha
    Young Hen Lee
    Hyung Suk Seo
    So Young Park
    Nan Hee Kim
    Sung Ho Hwang
    Hwan Seok Yong
    Yu-Whan Oh
    Eun-Young Kang
    Cherry Kim
    European Radiology, 2022, 32 : 1902 - 1911
  • [24] Different Perfusion Pattern Between Acute and Chronic Pulmonary Thromboembolism: Evaluation With Two-Phase Dual-Energy Perfusion CT
    Hong, Yoo Jin
    Kim, Ja Young
    Choe, Kyu Ok
    Hur, Jin
    Lee, Hye-Jeong
    Choi, Byoung Wook
    Kim, Young Jin
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (04) : 812 - 817
  • [25] Pulmonary Perfused Blood Volume with Dual-Energy CT as Surrogate for Pulmonary Perfusion Assessed with Dynamic Multidetector CT
    Fuld, Matthew K.
    Halaweish, Ahmed F.
    Haynes, Susan E.
    Divekar, Abhay A.
    Guo, Junfeng
    Hoffman, Eric A.
    RADIOLOGY, 2013, 267 (03) : 747 - 756
  • [26] Assessment of Perfusion Pattern and Extent of Perfusion Defect on Dual-Energy CT Angiography: Correlations between the Causes of Pulmonary Hypertension and Vascular Parameters
    Kim, Eun Young
    Seo, Joon Beom
    Oh, Sang Young
    Lee, Choong Wook
    Hwang, Hye Jeon
    Lee, Sang Min
    Lee, Young Kyung
    KOREAN JOURNAL OF RADIOLOGY, 2014, 15 (02) : 286 - 294
  • [27] Correlation study between dual source CT perfusion imaging and the microvascular composition of solitary pulmonary nodules
    Wang, Meng
    Li, Bangguo
    Sun, Hui
    Huang, Tingting
    Zhang, Xuemei
    Jin, Kaiyuan
    Wang, Feng
    Luo, Xianli
    LUNG CANCER, 2019, 130 : 115 - 120
  • [28] SOLITARY PULMONARY NODULES - EVALUATION WITH A CT REFERENCE PHANTOM
    HUSTON, J
    MUHM, JR
    RADIOLOGY, 1989, 170 (03) : 653 - 656
  • [29] Volumetric evaluation of dual-energy perfusion CT for the assessment of intrapulmonary clot burden
    Okada, M.
    Nakashima, Y.
    Kunihiro, Y.
    Sano, Y.
    Suga, K.
    Kido, S.
    Matsunaga, N.
    CLINICAL RADIOLOGY, 2013, 68 (12) : E669 - E675
  • [30] Hepatocellular nodules in liver cirrhosis: state of the art CT evaluation (perfusion CT/volume helical shuttle scan/dual-energy CT, etc.)
    Okada, Masahiro
    Kim, Tonsok
    Murakami, Takamichi
    ABDOMINAL IMAGING, 2011, 36 (03): : 273 - 281