Evaluation of dual-energy and perfusion CT parameters for diagnosing solitary pulmonary nodules

被引:19
|
作者
Zhu, Beilin [1 ]
Zheng, Shuo [1 ]
Jiang, Tao [1 ]
Hu, Bin [1 ]
机构
[1] Capital Med Univ, Beijing Chaoyang Hosp, Beijing, Peoples R China
关键词
dual-energy; perfusion; radiation dosage; solitary pulmonary nodules; COMPUTED-TOMOGRAPHY; LUNG-CANCER; TUMOR ANGIOGENESIS; ENHANCEMENT;
D O I
10.1111/1759-7714.14105
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background To evaluate the correlation and accuracy of dual-energy CT (DECT) (70/Sn150) and low-dose volume perfusion CT (VPCT) parameters for the diagnosis of solitary pulmonary nodules (SPN). Methods A total of 15 patients with benign SPN (mean age 56 +/- 7 years) and 34 patients with malignant SPN and clinical indication for surgery (mean age 58 +/- 6 years) were enrolled from July 2017 to September 2019 at a single institution. All the patients underwent low-dose VPCT with a scan volume of 114 mm on the z-axis and a venous phase enhancement DECT (70/150 Sn) scan just before surgery on the same day. All CT findings were studied in comparison with the pathological results after surgery. Perfusion and dual-energy CT parameters such as blood flow (BF), blood volume (BV), mean transit time (MTT), flow extraction product (FED), pulmonary nodule enhancement peak (PPnod) and iodine concentration (IC) were evaluated as well as t-test, chi-square test, Pearson correlation analysis, and ROC curve analysis to determine the significance of study parameters. Results The effective radiation dosage of the VPCT and DECT scans were 4.67 +/- 0.26 mSv and 0.32 +/- 0.10 mSv, respectively. Significant correlations were found between iodine concentration from DECT and VPCT parameters (r = 0.376-0.533, p < 0.05). The sensitivity and specificity of IC to differentiate the SPN were 86.67% and 72.73%, which was slightly lower than that of BV (94.44%, 73.33%), FED (88.89%, 80.00%) and PPnod (94.44%, 80.00%). Conclusions VPCT scans have low radiation dosage achieved by shortening the z-axis scan range for assessment of SPN. IC from DECT is significantly correlated with VPCT parameters, and VPCT parameters have better diagnostic performance for SPN than DECT parameters.
引用
收藏
页码:2691 / 2697
页数:7
相关论文
共 50 条
  • [31] Hepatocellular nodules in liver cirrhosis: state of the art CT evaluation (perfusion CT/volume helical shuttle scan/dual-energy CT, etc.)
    Masahiro Okada
    Tonsok Kim
    Takamichi Murakami
    Abdominal Imaging, 2011, 36 : 273 - 281
  • [32] Dual-Energy CT for Evaluation of Gout
    Black, D.
    Glazebrook, K.
    Michet, C.
    Berger, R.
    Kavros, S.
    McCollough, C.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (05)
  • [33] Dual-energy CT (DECT) lung perfusion in pulmonary hypertension: concordance rate with V/Q scintigraphy in diagnosing chronic thromboembolic pulmonary hypertension (CTEPH)
    Masy, Matthieu
    Giordano, Jessica
    Petyt, Gregory
    Hossein-Foucher, Claude
    Duhamel, Alain
    Kyheng, Maeva
    De Groote, Pascal
    Fertin, Marie
    Lamblin, Nicolas
    Bervar, Jean-Francois
    Remy, Jacques
    Remy-Jardin, Martine
    EUROPEAN RADIOLOGY, 2018, 28 (12) : 5100 - 5110
  • [34] Dual-energy CT in pulmonary vascular disease
    Vlahos, Ioannis
    Jacobsen, Megan C.
    Godoy, Myrna C.
    Stefanidis, Konstantinos
    Layman, Rick R.
    BRITISH JOURNAL OF RADIOLOGY, 2022, 95 (1129):
  • [35] Dual-energy CT (DECT) lung perfusion in pulmonary hypertension: concordance rate with V/Q scintigraphy in diagnosing chronic thromboembolic pulmonary hypertension (CTEPH)
    Matthieu Masy
    Jessica Giordano
    Grégory Petyt
    Claude Hossein-Foucher
    Alain Duhamel
    Maeva Kyheng
    Pascal De Groote
    Marie Fertin
    Nicolas Lamblin
    Jean-François Bervar
    Jacques Remy
    Martine Remy-Jardin
    European Radiology, 2018, 28 : 5100 - 5110
  • [36] Dual-energy lung perfusion and ventilation CT in children
    Goo, Hyun Woo
    PEDIATRIC RADIOLOGY, 2013, 43 (03) : 298 - 307
  • [37] Dual-energy lung perfusion and ventilation CT in children
    Hyun Woo Goo
    Pediatric Radiology, 2013, 43 : 298 - 307
  • [38] Can dual-energy CT replace perfusion CT for the functional evaluation of advanced hepatocellular carcinoma?
    Sébastien Mulé
    Frédéric Pigneur
    Ronan Quelever
    Arthur Tenenhaus
    Laurence Baranes
    Philippe Richard
    Vania Tacher
    Edouard Herin
    Hugo Pasquier
    Maxime Ronot
    Alain Rahmouni
    Valérie Vilgrain
    Alain Luciani
    European Radiology, 2018, 28 : 1977 - 1985
  • [39] Dual-energy perfusion-CT of pancreatic adenocarcinoma
    Klauss, M.
    Stiller, W.
    Pahn, G.
    Fritz, F.
    Kieser, M.
    Werner, J.
    Kauczor, H. U.
    Grenacher, L.
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (02) : 208 - 214
  • [40] Can dual-energy CT replace perfusion CT for the functional evaluation of advanced hepatocellular carcinoma?
    Mule, Sebastien
    Pigneur, Frederic
    Quelever, Ronan
    Tenenhaus, Arthur
    Baranes, Laurence
    Richard, Philippe
    Tacher, Vania
    Herin, Edouard
    Pasquier, Hugo
    Ronot, Maxime
    Rahmouni, Alain
    Vilgrain, Valerie
    Luciani, Alain
    EUROPEAN RADIOLOGY, 2018, 28 (05) : 1977 - 1985