Development of a flow standard to enable highly reproducible measurements of deformability of stored red blood cells in a microfluidic device

被引:15
|
作者
Robidoux, Jonathan [1 ]
Laforce-Lavoie, Audrey [1 ]
Charette, Steve J. [2 ]
Shevkoplyas, Sergey S. [3 ]
Yoshida, Tatsuro [4 ]
Brouard, Danny [1 ]
Lewin, Antoine [1 ]
机构
[1] Hema Quebec, Med Affairs & Innovat, Montreal, PQ, Canada
[2] Univ Laval, Biochem Microbiol & Bioinformat Dept, Montreal, PQ, Canada
[3] Univ Houston, Dept Biomed Engn, Houston, TX USA
[4] Hemanext Inc, Lexington, MA USA
关键词
ERYTHROCYTE DEFORMABILITY; MICROVASCULAR NETWORK; STORAGE LESION; TRANSFUSION; RHEOLOGY; PERFUSION; TOOL;
D O I
10.1111/trf.15770
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Great deformability allows red blood cells (RBCs) to flow through narrow capillaries in tissues. A number of microfluidic devices with capillary-like microchannels have been developed to monitor storage-related impairment of RBC deformability during blood banking operations. This proof-of-concept study describes a new method to standardize and improve reproducibility of the RBC deformability measurements using one of these devices. STUDY DESIGN AND METHODS The rate of RBC flow through the microfluidic capillary network of the microvascular analyzer (MVA) device made of polydimethylsiloxane was measured to assess RBC deformability. A suspension of microbeads in a solution of glycerol in phosphate-buffered saline was developed to be used as an internal flow rate reference alongside RBC samples in the same device. RBC deformability and other in vitro quality markers were assessed weekly in six leukoreduced RBC concentrates (RCCs) dispersed in saline-adenine-glucose-mannitol additive solution and stored over 42 days at 4 degrees C. RESULTS The use of flow reference reduced device-to-device measurement variability from 10% to 2%. Repeated-measure analysis using the generalized estimating equation (GEE) method showed a significant monotonic decrease in relative RBC flow rate with storage from Week 0. By the end of storage, relative RBC flow rate decreased by 22 +/- 6% on average. CONCLUSIONS The suspension of microbeads was successfully used as a flow reference to increase reproducibility of RBC deformability measurements using the MVA. Deformability results suggest an early and late aging phase for stored RCCs, with significant decreases between successive weeks suggesting a highly sensitive measurement method.
引用
收藏
页码:1032 / 1041
页数:10
相关论文
共 50 条
  • [41] The mechanical properties of stored red blood cells measured by a convenient microfluidic approach combining with mathematic model
    Wang, Ying
    You, Guoxing
    Chen, Peipei
    Li, Jianjun
    Chen, Gan
    Wang, Bo
    Li, Penglong
    Han, Dong
    Zhou, Hong
    Zhao, Lian
    BIOMICROFLUIDICS, 2016, 10 (02):
  • [42] Decreased deformability of the X-ray-irradiated red blood cells stored in mannitol-adenine-phosphate medium
    Suzuki, Y
    Tateishi, N
    Cicha, I
    Shiba, M
    Muraoka, M
    Tadokoro, K
    Maeda, N
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2000, 22 (02) : 131 - 141
  • [43] Dynamics of Individual Red Blood Cells Under Shear Flow: A Way to Discriminate Deformability Alterations
    Atwell, Scott
    Badens, Catherine
    Charrier, Anne
    Helfer, Emmanuele
    Viallat, Annie
    FRONTIERS IN PHYSIOLOGY, 2022, 12
  • [44] DEFORMABILITY OF YOUNG, OLD, LIQUID STORED, FROZEN AND REJUVENATED RED-BLOOD-CELLS (RBC) AS MEASURED BY LASER EKTACYTOMETRY
    SERRALLACH, EN
    COLMER, K
    CATSIMPOOLAS, N
    VALERI, CR
    EMERSON, CP
    BIOPHYSICAL JOURNAL, 1981, 33 (02) : A176 - A176
  • [45] INVESTIGATIONS ON THE DEFORMABILITY OF HUMAN RED-BLOOD-CELLS STORED IN DIFFERENT PRESERVATIVE SOLUTIONS - INFLUENCE OF CHANGED MEDIUM COMPOSITION
    WEGNER, G
    KUCERA, W
    LERCHE, D
    BIOMEDICA BIOCHIMICA ACTA, 1987, 46 (07) : 605 - 609
  • [46] Artificial Microvascular Network: A New Device for Measuring Rheological Properties of Stored Red Blood Cells
    Burns, J. M.
    Forouzan, O.
    Sosa, J. M.
    Shevkoplyas, S. S.
    TRANSFUSION, 2011, 51 : 9A - 9A
  • [47] Stored red-blood-cells inhibit platelet function under physiologic flow
    Morrison, A.
    McMillan, L.
    Hornsey, V. S.
    Prowse, C. V.
    VOX SANGUINIS, 2010, 99 (04) : 362 - 368
  • [48] Microparticles in stored red blood cells: an approach using flow cytometry and proteomic tools
    Rubin, O.
    Crettaz, D.
    Canellini, G.
    Tissot, J. -D.
    Lion, N.
    VOX SANGUINIS, 2008, 95 (04) : 288 - 297
  • [49] A Microfluidic Device for Simultaneous Extraction of Plasma, Red Blood Cells, and On-Chip White Blood Cell Trapping
    Kuan, Da-Han
    Wu, Chia-Chien
    Su, Wei-Yu
    Huang, Nien-Tsu
    SCIENTIFIC REPORTS, 2018, 8
  • [50] A Microfluidic Device for Simultaneous Extraction of Plasma, Red Blood Cells, and On-Chip White Blood Cell Trapping
    Da-Han Kuan
    Chia-Chien Wu
    Wei-Yu Su
    Nien-Tsu Huang
    Scientific Reports, 8