Development of a flow standard to enable highly reproducible measurements of deformability of stored red blood cells in a microfluidic device

被引:15
|
作者
Robidoux, Jonathan [1 ]
Laforce-Lavoie, Audrey [1 ]
Charette, Steve J. [2 ]
Shevkoplyas, Sergey S. [3 ]
Yoshida, Tatsuro [4 ]
Brouard, Danny [1 ]
Lewin, Antoine [1 ]
机构
[1] Hema Quebec, Med Affairs & Innovat, Montreal, PQ, Canada
[2] Univ Laval, Biochem Microbiol & Bioinformat Dept, Montreal, PQ, Canada
[3] Univ Houston, Dept Biomed Engn, Houston, TX USA
[4] Hemanext Inc, Lexington, MA USA
关键词
ERYTHROCYTE DEFORMABILITY; MICROVASCULAR NETWORK; STORAGE LESION; TRANSFUSION; RHEOLOGY; PERFUSION; TOOL;
D O I
10.1111/trf.15770
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Great deformability allows red blood cells (RBCs) to flow through narrow capillaries in tissues. A number of microfluidic devices with capillary-like microchannels have been developed to monitor storage-related impairment of RBC deformability during blood banking operations. This proof-of-concept study describes a new method to standardize and improve reproducibility of the RBC deformability measurements using one of these devices. STUDY DESIGN AND METHODS The rate of RBC flow through the microfluidic capillary network of the microvascular analyzer (MVA) device made of polydimethylsiloxane was measured to assess RBC deformability. A suspension of microbeads in a solution of glycerol in phosphate-buffered saline was developed to be used as an internal flow rate reference alongside RBC samples in the same device. RBC deformability and other in vitro quality markers were assessed weekly in six leukoreduced RBC concentrates (RCCs) dispersed in saline-adenine-glucose-mannitol additive solution and stored over 42 days at 4 degrees C. RESULTS The use of flow reference reduced device-to-device measurement variability from 10% to 2%. Repeated-measure analysis using the generalized estimating equation (GEE) method showed a significant monotonic decrease in relative RBC flow rate with storage from Week 0. By the end of storage, relative RBC flow rate decreased by 22 +/- 6% on average. CONCLUSIONS The suspension of microbeads was successfully used as a flow reference to increase reproducibility of RBC deformability measurements using the MVA. Deformability results suggest an early and late aging phase for stored RCCs, with significant decreases between successive weeks suggesting a highly sensitive measurement method.
引用
收藏
页码:1032 / 1041
页数:10
相关论文
共 50 条
  • [21] A Microfluidic Deformability Assessment of Pathological Red Blood Cells Flowing in a Hyperbolic Converging Microchannel
    Faustino, Vera
    Rodrigues, Raquel O.
    Pinho, Diana
    Costa, Elisio
    Santos-Silva, Alice
    Miranda, Vasco
    Amaral, Joana S.
    Lima, Rui
    MICROMACHINES, 2019, 10 (10)
  • [22] Deformation of Red Blood Cells, Air Bubbles, and Droplets in Microfluidic Devices: Flow Visualizations and Measurements
    Bento, David
    Rodrigues, Raquel O.
    Faustino, Vera
    Pinho, Diana
    Fernandes, Carla S.
    Pereira, Ana I.
    Garcia, Valdemar
    Miranda, Joao M.
    Lima, Rui
    MICROMACHINES, 2018, 9 (04):
  • [23] Washing of stored red blood cells by an autotransfusion device before transfusion
    de Vroege, R.
    Wildevuur, W. R.
    Muradin, J. A. G.
    Graves, D.
    van Oeveren, W.
    VOX SANGUINIS, 2007, 92 (02) : 130 - 135
  • [24] A Simple Disposable Device for Bedside Washing of Stored Red Blood Cells
    Voros, E.
    Piety, N. Z.
    Shevkoplyas, S. S.
    TRANSFUSION, 2016, 56 : 55A - 55A
  • [25] Dielectrophoretic separation of Circulating Tumor Cells and Red Blood Cells in a microfluidic device
    Chiriac, Eugen
    Avram, Marioara
    Balan, Corneliu
    CAS 2020 PROCEEDINGS: 2020 INTERNATIONAL SEMICONDUCTOR CONFERENCE, 2020, : 211 - 214
  • [26] High Deformability of Plasmodium vivax-Infected Red Blood Cells under Microfluidic Conditions
    Handayani, Sarwo
    Chiu, Daniel T.
    Tjitra, Emiliana
    Kuo, Jason S.
    Lampah, Daniel
    Kenangalem, Enny
    Renia, Laurent
    Snounou, Georges
    Price, Ric N.
    Anstey, Nicholas M.
    Russell, Bruce
    JOURNAL OF INFECTIOUS DISEASES, 2009, 199 (03): : 445 - 450
  • [27] Extensional flow for assessing the effect of nanocarriers on the mechanical deformability of red blood cells
    Kriebel, Jana
    Goncalves, Ines M.
    Baptista, Vitoria
    Veiga, Maria I.
    Minas, Graca
    Lima, Rui
    Catarino, Susana O.
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2023, 146
  • [28] Effect of heat on stored red cells during non-flow conditions in a blood-warming device
    Eastlund, T
    Van Duren, A
    Clay, ME
    VOX SANGUINIS, 1999, 76 (04) : 216 - 219
  • [29] Deformability Based Sorting of Stored Red Blood Cells Reveals Donor-Dependent Aging Curves
    Islamzada, Emel
    Matthews, Kerryn
    Guo, Quan
    Santoso, Aline
    Scott, Mark D.
    Ma, Hongshen
    BLOOD, 2019, 134
  • [30] Deformability based sorting of stored red blood cells reveals donor-dependent aging curves
    Islamzada, Emel
    Matthews, Kerryn
    Guo, Quan
    Santoso, Aline T.
    Duffy, Simon P.
    Scott, Mark D.
    Ma, Hongshen
    LAB ON A CHIP, 2020, 20 (02) : 226 - 235