Development of a flow standard to enable highly reproducible measurements of deformability of stored red blood cells in a microfluidic device

被引:15
|
作者
Robidoux, Jonathan [1 ]
Laforce-Lavoie, Audrey [1 ]
Charette, Steve J. [2 ]
Shevkoplyas, Sergey S. [3 ]
Yoshida, Tatsuro [4 ]
Brouard, Danny [1 ]
Lewin, Antoine [1 ]
机构
[1] Hema Quebec, Med Affairs & Innovat, Montreal, PQ, Canada
[2] Univ Laval, Biochem Microbiol & Bioinformat Dept, Montreal, PQ, Canada
[3] Univ Houston, Dept Biomed Engn, Houston, TX USA
[4] Hemanext Inc, Lexington, MA USA
关键词
ERYTHROCYTE DEFORMABILITY; MICROVASCULAR NETWORK; STORAGE LESION; TRANSFUSION; RHEOLOGY; PERFUSION; TOOL;
D O I
10.1111/trf.15770
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Great deformability allows red blood cells (RBCs) to flow through narrow capillaries in tissues. A number of microfluidic devices with capillary-like microchannels have been developed to monitor storage-related impairment of RBC deformability during blood banking operations. This proof-of-concept study describes a new method to standardize and improve reproducibility of the RBC deformability measurements using one of these devices. STUDY DESIGN AND METHODS The rate of RBC flow through the microfluidic capillary network of the microvascular analyzer (MVA) device made of polydimethylsiloxane was measured to assess RBC deformability. A suspension of microbeads in a solution of glycerol in phosphate-buffered saline was developed to be used as an internal flow rate reference alongside RBC samples in the same device. RBC deformability and other in vitro quality markers were assessed weekly in six leukoreduced RBC concentrates (RCCs) dispersed in saline-adenine-glucose-mannitol additive solution and stored over 42 days at 4 degrees C. RESULTS The use of flow reference reduced device-to-device measurement variability from 10% to 2%. Repeated-measure analysis using the generalized estimating equation (GEE) method showed a significant monotonic decrease in relative RBC flow rate with storage from Week 0. By the end of storage, relative RBC flow rate decreased by 22 +/- 6% on average. CONCLUSIONS The suspension of microbeads was successfully used as a flow reference to increase reproducibility of RBC deformability measurements using the MVA. Deformability results suggest an early and late aging phase for stored RCCs, with significant decreases between successive weeks suggesting a highly sensitive measurement method.
引用
收藏
页码:1032 / 1041
页数:10
相关论文
共 50 条
  • [31] Development of a Microfluidic Device for Blood Cells Extraction in Liquid Biopsy
    Caragnano, Stefania
    Villarreal, Angeles Ivon Rodriguez
    Terre, Jasmina Casals
    Petruzzellis, Isabella
    Ancona, Antonio
    Osellame, Roberto
    Vazquez, Rebeca Martinez
    Volpe, Annalisa
    EOS ANNUAL MEETING, EOSAM 2024, 2024, 309
  • [32] High throughput detection and characterization of red blood cells deformability by combining optical tweezers with microfluidic technique
    Zhang M.
    Meng X.
    Zhu L.
    Shengwu Yixue Gongchengxue Zazhi/Journal of Biomedical Engineering, 2020, 37 (05): : 848 - 854
  • [33] Levitation of red blood cells in microchannel for microfluidic MEMS healthcare device application
    Kumar, Mahesh
    Palekar, Nikhil
    Kumar, Ashish
    Sharma, Niti Nipun
    Akhtar, Jamil
    Singh, Kulwant
    MATERIALS TODAY-PROCEEDINGS, 2021, 46 : 5861 - 5865
  • [34] Microfluidic evaluation of red cells collected and stored in modified processing solutions used in blood banking
    Wang, Yimeng
    Giebink, Adam
    Spence, Dana M.
    INTEGRATIVE BIOLOGY, 2014, 6 (01) : 65 - 75
  • [35] Modeling the Effect of Red Blood Cells Deformability on Blood Flow Conditions in Human Carotid Artery Bifurcation
    Urevc, Janez
    Zun, Iztok
    Brumen, Milan
    Stok, Boris
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2017, 139 (01):
  • [36] EFFECTS OF CONTINUOUS-FLOW WASHING ON STORED RED BLOOD-CELLS
    BUTTON, LN
    KEVY, SV
    SHOHET, SB
    OXMAN, MN
    TRANSFUSION, 1972, 12 (02) : 84 - &
  • [37] Geometry effect in multi-step crossflow microfluidic devices for red blood cells separation and deformability assessment
    Vera Faustino
    Diana Pinho
    Susana O. Catarino
    Graça Minas
    Rui A. Lima
    Biomedical Microdevices, 2022, 24
  • [38] Geometry effect in multi-step crossflow microfluidic devices for red blood cells separation and deformability assessment
    Faustino, Vera
    Pinho, Diana
    Catarino, Susana O.
    Minas, Graca
    Lima, Rui A.
    BIOMEDICAL MICRODEVICES, 2022, 24 (02)
  • [39] HistoFlex-a microfluidic device providing uniform flow conditions enabling highly sensitive, reproducible and quantitative in situ hybridizations
    Soe, Martin Jensen
    Okkels, Fridolin
    Sabourin, David
    Alberti, Massimo
    Holmstrom, Kim
    Dufva, Martin
    LAB ON A CHIP, 2011, 11 (22) : 3896 - 3907
  • [40] Optical measurements of stored human red blood cells with and without CPDA-1
    Lee, SangYun
    Park, HyunJoo
    Park, YongKeun
    2016 ASIA COMMUNICATIONS AND PHOTONICS CONFERENCE (ACP), 2016,