Speckle-Based X-Ray Dark-Field Tomography of an Attenuating Object

被引:3
|
作者
Alloo, S. J. [1 ]
Paganin, D. M. [2 ]
Morgan, K. S. [2 ]
Kitchen, M. J. [2 ]
Stevenson, A. W. [3 ]
Mayo, S. C. [4 ]
Li, H. T. [5 ]
Kennedy, B. M. [6 ]
Maksimenko, A. [3 ]
Bowden, J. [4 ]
Pavlov, K. M. [1 ,2 ,7 ]
机构
[1] Univ Canterbury, Sch Phys & Chem Sci, Christchurch 8041, New Zealand
[2] Monash Univ, Sch Phys & Astron, Clayton, Vic 3800, Australia
[3] Australian Synchrotron, ANSTO, Clayton, Vic 3168, Australia
[4] Commonwealth Sci & Ind Res Org, Clayton, Vic 3168, Australia
[5] Univ Canterbury, Sch Math, Christchurch 8041, New Zealand
[6] Univ Canterbury, Sch Earth & Environm, Christchurch 8041, New Zealand
[7] Univ New England, Armidale, NSW 2351, Australia
来源
基金
澳大利亚研究理事会;
关键词
Speckle-Based X-Ray Imaging; Phase-Contrast Imaging; Dark-Field Imaging; Computed Tomography; PHASE-CONTRAST; COMPUTED-TOMOGRAPHY; IMAGE; RETRIEVAL;
D O I
10.1117/12.2597722
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Spatial resolution in standard phase-contrast X-ray imaging is limited by the finite number and size of detector pixels. This limits the size of features that can be seen directly in projection images or tomographic reconstructions. Dark-field imaging allows information regarding such features to be obtained, as the reconstructed image is a measure of the position-dependent small-angle X-ray scattering of incident rays from the unresolved microstructure. In this paper we utilize an intrinsic speckle-tracking-based X-ray imaging technique to obtain the effective dark-field signal from a wood sample. This effective dark-field signal is extracted using a Fokker-Planck type formalism, which models the deformations of illuminating reference-beam speckles due to both coherent and diffusive scatter from the sample. We here assume that (a) small-angle scattering fans at the exit surface of the sample are rotationally symmetric, and (b) the object has both attenuating and refractive properties. The associated inverse problem, of extracting the effective dark-field signal, is numerically stabilised using a \weighted determinants" approach. Effective dark-field projection images are presented, as well as the dark-field tomographic reconstructions obtained using Fokker-Planck implicit speckle-tracking.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Detection of sub-pixel fractures in X-ray dark-field tomography
    Lauridsen, Torsten
    Willner, Marian
    Bech, Martin
    Pfeiffer, Franz
    Feidenhans'l, Robert
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2015, 121 (03): : 1243 - 1250
  • [42] Anisotropic X-Ray Dark-Field Tomography: A Continuous Model and its Discretization
    Wieczorek, M.
    Schaff, F.
    Pfeiffer, F.
    Lasser, T.
    PHYSICAL REVIEW LETTERS, 2016, 117 (15)
  • [43] Detection of sub-pixel fractures in X-ray dark-field tomography
    Torsten Lauridsen
    Marian Willner
    Martin Bech
    Franz Pfeiffer
    Robert Feidenhans’l
    Applied Physics A, 2015, 121 : 1243 - 1250
  • [44] Single-Shot X-Ray Speckle-Based Imaging of a Single-Material Object
    Pavlov, Konstantin M.
    Li, Heyang
    Paganin, David M.
    Berujon, Sebastien
    Rouge-Labriet, Helene
    Brun, Emmanuel
    PHYSICAL REVIEW APPLIED, 2020, 13 (05)
  • [45] Energy weighted x-ray dark-field imaging
    Pelzer, Georg
    Zang, Andrea
    Anton, Gisela
    Bayer, Florian
    Horn, Florian
    Kraus, Manuel
    Rieger, Jens
    Ritter, Andre
    Wandner, Johannes
    Weber, Thomas
    Fauler, Alex
    Fiederle, Michael
    Wong, Winnie S.
    Campbell, Michael
    Meiser, Jan
    Meyer, Pascal
    Mohr, Juergen
    Michel, Thilo
    OPTICS EXPRESS, 2014, 22 (20): : 24507 - 24515
  • [46] Signal decomposition for X-ray dark-field imaging
    Pattern Recognition Lab, Friedrich-Alexander-University Erlangen-Nuremberg, Erlangen, Germany
    不详
    不详
    Kaeppler, Sebastian, 1600, Springer Verlag (8673):
  • [47] X-ray Dark-field Chest Radiography of Lymphangioleiomyomatosis
    Gassert, Florian T.
    Pfeiffer, Franz
    RADIOLOGY, 2022, 303 (03) : 499 - 500
  • [48] Review and experimental verification of x-ray dark-field signal interpretations with respect to quantitative isotropic and anisotropic dark-field computed tomography
    Graetz, J.
    Balles, A.
    Hanke, R.
    Zabler, S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (23):
  • [49] Signal Decomposition for X-ray Dark-Field Imaging
    Kaeppler, Sebastian
    Bayer, Florian
    Weber, Thomas
    Maier, Andreas
    Anton, Gisela
    Hornegger, Joachim
    Beckmann, Matthias
    Fasching, Peter A.
    Hartmann, Arndt
    Heindl, Felix
    Michel, Thilo
    Oezguel, Gueluemser
    Pelzer, Georg
    Rauh, Claudia
    Rieger, Jens
    Schulz-Wendtland, Ruediger
    Uder, Michael
    Wachter, David
    Wenkel, Evelyn
    Riess, Christian
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2014, PT I, 2014, 8673 : 170 - +
  • [50] Prototype combines the classical X-RAY CT and dark-field X-Ray Method
    不详
    RADIOLOGIE, 2022, 62 (03): : 198 - 198